Loading...
HomeMy WebLinkAboutObservation of Excavation 03.26.2020K+A Kumar & Associates, Inc. Geotechnical and Materials Engineers and Environmental Scientists 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado March 26, 2020 Darren Gallegos 58 Surrey Street Carbondale, Colorado 81623 darrengallegos@hotmail.com Project No. 20-7-200 Subject: Observation of Excavation, Proposed Residence, Lot 11, Ranch Creek PUD, Ranch at Roaring Fork, Surrey Street, Garfield County, Colorado Dear Darren: As requested, a representative of Kumar & Associates, Inc. observed the excavation at the subject site on March 23, 2020 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to you, dated March 23, 2020. The proposed residence will be a two-story wood frame structure with an attached garage. The main floor and garage floor will be slab -on -grade. Footing foundations were designed for an assumed allowable soil bearing pressure of 1,500 psf. At the time of our visit to the site, the foundation excavation was about 90% complete and had been cut in one level about 21/2 feet below the adjacent ground surface. The garage footing trench had not been excavated and the small area south of the garage is planned to be excavated down an additional 10 inches. The soils exposed in the bottom of the excavation consisted of medium dense, slightly silty sandy gravel with cobbles and scattered small boulders. The results of a gradation analysis performed on a sample of slightly silty sandy gravel (minus 3-inch fraction) obtained from the site are presented on Figure 1. No free water was encountered in the excavation and the soils were slightly moist to moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1,500 psf can be used for support of the proposed residence. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils in footing areas should be removed and the bearing level extended down to the undisturbed natural soils. The bearing soils should be protected against frost and concrete should not be placed on frozen soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures (if any) should also be designed Darren Gallegos March 26, 2020 Page 2 to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 45 pcf for on - site soil as backfill. A perimeter foundation drain should not be needed for the proposed slab -on - grade main floor. Structural fill placed within floor slab areas can consist of the on -site soils (4-inch minus) compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, Inc Daniel E. Hardii Rev. by: SLP DEH/lac attachment Figure 1 — Gradation Test Results cc: Studio M — Mic Baca studiom.engineer@gmail.com Kumar & Associates, Inc. Project No. 20-7-200 HYDROMETER ANALYSIS SIEVE ANALYSIS 100 TIME READINGS 24 HRS 7 HRS 45 MIN 15 MIN 6014111 19MIN 4MIN WIN U.S. STANDARD SERIES 0 1 • CLEAR SQUARE OPENINGS 3 4' 8'6' -'0 I- I 90 — 1 r 10 I 1 -- 80 I I I 20 f I 70 I I I ---------♦ I I 30 I so T — - - 1 t 50 I } I 60 1 ao I } 1 so 4 20 —-- —1 - 80 10 — I 1 90 -I- - 0 I I III I._.= I I LI1 I L I 1 11 i T 1 I I R11__ 1-1-1.1 1 1 I I I = 100 _—L __LI1 _I —I .001 .002 .005 .009 .019 .037 .075 .150 .300 I .600 1.18 12.36 4.75 9 5 19 38.1 76.2 127 .425 2.0 152 DIAMETER OF PARTICLES IN MILLIMETERS 200 CLAY TO SILT SA ND GRAVEL FINE MEDIUM COARSE MEDIUM FINE COBBLES GRAVEL 59 % SAND 31 % SILT AND CLAY 10 % LIQUID LIMIT PLASTICITY INDEX SAMPLE OF: Slightly Silty Sandy Gravel FROM: SE Corner of Excavation at Footing Grade These fest results apply only to the samples which were tested. The testing report shall not be reproduced, except in full, without the written approval of Kumar & Associates, Inc. Sieve analysis testing is performed in accordance with ASTM D6913, ASTM D7928, ASTM C136 and/or ASTM D1140. 20-7-200 Kumar & Associates GRADATION TEST RESULTS Fig. 1