Loading...
HomeMy WebLinkAboutSite PlanG:\2019\19219\CIVIL DWGS\DE\19219-DE-OWTS SITE.DWG - Apr 21, 2020 - 12:58pm a lie: J S OPRIS ENGINEERING, LLC. CIVIL CONSULTANTS MAINSTREET RE WIRE FENCE 7 CAR502 81623 (970)704-0311 FAX:(970)-704-0313 �. ,,,• REG x GENERAL UTILITY NOTES: 4'•o:. cis{ NI� =_ U) 1. THE LOCATIONS OF UNDERGROUND UTILITIES HAVE BEEN PLOTTED BASED ON THE EXISTING SURVEY PROVIDED BY SOPRIS ENGINEERING. THESE UTILITIES, AS SHOWN, MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE• CONTRACTOR TO OBTAIN LOCATES OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. � C • / 28377 4 -0 •. s q 2. ALL UTILITIES, BOTH UNDERGROUND AND OVERHEAD, SHALL BE MAINTAINED IN CONTINUOUS SERVICE THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR ANY DAMAGES TO, OR `S/ONAl- Er�0 rl?yyxzttLa ,,, ROCKFORD DITCH LATERAL SYSTEM 3 U) INTERRUPTION OF, SERVICES CAUSED BY THE CONSTRUCTION. 3. THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION OPERATIONS TO WITHIN THE DESIGNED BY PER 04/15/20 RECEPTION N o 23639 SITE BOUNDARIES. THE CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR EXPRESSED CONSENT OF THE OWNER OR PUBLIC UTILITY DRAWN BY PER 04/17/20 x . REPRESENTATIVES. CHECKED BY YTN 04/17/20 O a) 4. ANY DAMAGE TO PUBLIC OR PRIVATE PROPERTY BY THE CONTRACTOR OUTSIDE THESE LIMITS WITHOUT THE PERMISSION OF THE PUBLIC OR PRIVATE OWNER OR UTILITY DATE: APRIL 17, 2020 COMPANY REPRESENTATIVES WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 5. ALL WATER SERVICES SHALL BE INSTALLED WITH A 7' MINIMUM DEPTH OF COVER. IF JOB NO. 19219.01 O 6N. 4S0 I w I W L. LQ IBC 0 LL CC a) m GRADE CONFLICTS OCCUR WITH EXISTING UTILITIES, THE PROPOSED WATER MAIN GRADE CAN BE VARIED PROVIDED THAT THE MINIMUM DEPTH OF COVER IS MAINTAINED. 6. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION, SCHEDULING, AND INSTALLATION OF NATURAL GAS, ELECTRIC, CABLE TELEVISION AND TELEPHONE UTILITIES PURSUANT TO SPECIFICATIONS AND UTILITY SERVICE AGREEMENTS WITH THE UTILITY PROVIDERS. GENERAL CONSTRUCTION NOTES: NDALE, CO (STEM PROPERTY LINE (TYP) BASIS OF BEARING ~ v 1. ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A SET OF APPROVED CONSTRUCTION N 89°22'00" W 145.00 r n DOCUMENTS ON SITE AT ALL TIMES. Q V I SURVEY SOPRIS 2. AND PLAT INFORMATION FROM ISP BY ENGINEERING. THESE UTILITIES, AS OWTS. SEE SHEET C 2.0 10' m 0 w SHOWN, MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE 10' 47' - CONTRACTOR TO OBTAIN LOCATES OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. 15' U 0 X - 0� ~ `� 3. EXISTING CONTOURS ARE AT 1' FOOT INTERVALS. Q I- PROPOSED WATER EXISTING OVERHEAD g �� (J O PROPOSED r ELECTRIC Q � S SERVICE CURB STOP n / WATER SERV!, E 4. PROPOSED CONTOURS ARE AT 1' FOOT INTERVALS. ^ 0 �J J / 1.0 W W W W �� W C.S. TAP 5. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATIONS AND PROTECTION OF z 12 ` 6titi� ALL EXISTING UTILITIES SHOWN, ALL EXISTING UTILITIES NOT SHOWN, AND ALL PROPOSED O / ETC -C PROPOSED / 28' EXISTING UTILITIES ON THESE PLANS. THESE UTILITIES EITHER UNDERGROUND OR OVERHEAD, SHALL BE �- UNDERGROUND GAS MAINTAINED IN CONTINUOUS SERVICE THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. THE H $ $ 02-BEDROOM DWELLING /" �" n. T CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR ANY DAMAGE TO, OR INTERRUPTION OF w Q FFE: SERVICES CAUSED BY THE CONSTRUCTION.LLI U XR + 0 .5' ABO/., a)3 ®f 6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING CONDITIONS AUTSIDE THE NATED IMPROVEMENT AREA FROM DAMAGE. ANY AMAGE TO EXISTINGV TTRUCTION �1 J16' CL EXISTING FENCE SOOO' IPROPOSED SETcHALL, A AREAS OUTSIDE TEDES GNATED IMPROVEMENT AREA DURING COSA MACE RESIDEN AMENDED LOTS 15-16, BLK ONSITE WASTEWATER TREP BUILDING PERMIT AP MINIMUM, BE RESTORED TO A STATE EQUAL TO ITS PRE CONSTRUCTION STATE. WATER ASSUMED LOCATION SERVICE PIPEIGHT ELECTRIC SERVICE PANEL 0 OF WAY & EASEMENT 7. THE GENERAL CONTRACTOR SHALL PERFORM THE WORK ACCORDING TO ALL LOCAL FORTH TRANSPORTAT ON OF NATURAL GAS GOVERNMENT, COUNTY, STATE, AND FEDERAL SAFETY AND HEALTH REGULATIONS. IN OTHER SUBSTANCE "TRENCHING" "OPEN '• F--I L < 1- () 3 PER GR NT RECORDED AS RECEPTION IN A PIPE NOVEMBER 19, 2002 No. 614883 PARTICULAR, THE AND EXCAVATION" OPERATIONS SHALL COMPLY WITH ALL CURRENT O.S.H.A. REGULATORY REQUIREMENTS. FTc Q LO ATED UNDERGROUND GAS LINE 8. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY AFTER "NORMAL WORKING HOURS". AT THE END OF EACH DAY'S WORK AND AT OTHER TIMES WHEN CONSTRUCTION DAVID DYLAN MACE MARCH 17, 2008 OPERATIONS ARE SUSPENDED FOR ANY REASON, THE CONTRACTOR SHALL REMOVE ALL LOTS 15-16 & LOT D-BLOCK 9, NOWN IF THERE IS SERVICE TO EQUIPMENT AND OTHER OBSTRUCTIONS FROM THE PUBIC RIGHT-OF-WAY. etc I �tJB CT PROPERTY x AMENDED TOWNSITE OF COOPERTON RECEPTION No. 280258 - PROPOSED GRAVEL AFT DRIVEWAY & 12' EXISTING GRAVEL c, 1 to = LOCATE w OR 0 HER GAS WAS P• EFORMED ON ADJACEN LINES FOR OTHERS PROPERTY 9. CONTRACTOR SHALL NOTIFY ALL PUBLIC OR PRIVATE UTILITY OWNERS FORTY-EIGHT HOURS PRIOR TO COMMENCEMENT OF WORK ADJACENT TO THE UTILITY. ASSESSOR PARCEL 2393-284-09-015 DRIVEWA I i 5 sq. ft. 0.280 acres PARKING I 10. ALL GEOTECHNICAL RECOMMENDATIONS TO BE ADHERED TO. zz x 6ti21 EXISTING �,_j II 12" CMP CULVERT X 6128 _ E EXISTING ELECTRIC SERVICE METER SET FTc 12' 0 EEC PROPOSED LEGEND w0 �c 6129 H O R:iORDDiTCH! TELEPHONE, AND CABLE o LTERALSYSTEM \ SERVICE PEDESTAL6128 8" WL8 WLPROPOSED 8" WATER MAIN Q ETC ETC PROPOSED ELEC, TELE, CABLE ECP3TIO9N No. _J PROPOSED CURB STOP NI ELECTRIC 6129 - T TRANSFORMER I- 0 EXISTING WATER LINE GENERAL NOTES: 6127 X 1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING. X X -� X X X145.00' X 2. THE PROPOSED LOT CONDITIONS AND SURVEY INFORMATION BY SOPRIS ENGINEERING AND OTHERS /1 N 89$2�`�00� ►-PROP-MTV-ME 1 i 1 �[7y�C �TYP� ♦V 3. THE EXISITNG LOT CONDITIONS PER COUNTY GIS DATA BASE, AERIAL MAPPING, LIDAR TOPOGRAPHY AND Y W W SURVEY INFORMATION BY SOPRIS ENGINEERING WIRE 6130 FENCE / 4. PRIMARY OWNER NAME AND ADDRESS: MACE, DAVID DYLAN 88 CEDAR ST CARBONDALE, CO 81623 5. LEGAL SUMMARY: COOPERTON TWNSTE. BLOCK: 9 LOT: 15 AND 16 INCLUDES LOT D 6. SITE ADDRESS: 88 CEDAR ST, CARBONDALE, CO 81623 �titi? 11► 4I1 W W W O 7. Parcel Number: 239328409015 8. GARFIELD COUNTY PERMIT #: ISSUED 9. CONTRACTOR: DATE REVISION FOUND #5 REBAR & / / PLASTIC CAP 00/00/00 XXX L.S. 14111 / III 1.5' CORRUGATED METAL PIP' / 6128 --- ------------------- III 111 III 111 III "J GRAPHIC SCALE TITLE SITE UTILITY DESIGN CONSTRUCTION PLAN 10 0 05 10 20 40 DRAWING NO. C-1.0 ( IN FEET ) 1 inch = 10 ft. G:\2019\19219\CIVIL DWGS\DE\19219-DE-OWTS SITE.DWG - Apr 21, 2020 - 12:58pm x PRESSURE DOSE TRANSPORT PIPE. USE 1.25 SCHD-40 W/ S OPRIS ENGINEERING, LLC. 3.0' MIN. DEPTH OF BURY. BED PIPE W/CL-6 ROAD BASE. INSTALL 2-COMPARTMENT 1250-GALLON CONCRETE SEPTIC TANK Design Calculations OWTS CIVIL CONSULTANTS INSTALL AT MIN. 2.5% TO ALLOW DRAIN BACK TO TANK. (VALLEY PRECAST ITEM # 1250t-2CP-HH) INSTALL WITH (2) 24" DIA. BY 24" DEEP RIBBED PVC RISERS W/ LIDS AT THE INSTALL 4" RISER PIPE INSPECTION PORT AT SURFACE. INSTALL ORENCO SIMPLEX EFFLUENT PUMP ASSEMBLY. EACH END CHAMBER (TYP.) (PVU57-1819-L) L) W/P300511 PUMP), W/ 1.25" DISCHARGE ASSEMBLIES. NSTALL 1.25" FLUSH BALL VALVE ASSEMBLY ON OWTS SYSTEM NOTES Design Calculations OWTS 1. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO STATE AND COUNTY ONSITE Installation of an OWTS with a minimum 3-bedroom capacity. WASTEWATER TREATMENT SYSTEM (OWTS) REGULATIONS. From County State Regulation 43: 502 MAIN STREET CARBONDALE, CO 81623 (970) 70a-o311 FAX: (970)-704-0313 DEPTH TO TOP OF TANK FROM PROPOSED GRADE IS APPROX. 2'. END OF EACH DISTRIBUTION LATERAL. BELOW adopted Minimum based 3 bedrooms = 6 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR EACH INSPECTION PORT(TYP. END EA. ROW)tip' INSTALL UNDERGROUND ELECTRICAL & CONTROL PROPERTY LINE (TYP) PUMPS WITHIN SEWER PIPE TRENCH & CONTROLS. DIRECT BURY UV WIRES OR WIRES IN CONDUIT R S 0 O O I �. I population on persons. First 3 bedrooms(2 persons/bedroom) Over 3 bedrooms(1personper bedroom)FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND EXCAVATION. p / ) Gallons per day per person =75 gal/person/day, No peaking factor Max. Design flow (Qd)gallons/day = (# of people) x (avg. flow)gal/person/day. 3. ALL SEWER LINES TO BE SDR-35 BEDDED IN CLASS 6, SDR-26 BEDDED IN SCREENED NATIVE OR SCHEDULE 40 P.V.C. PIPE BEDDED IN SCREENED NATIVE MATERIAL UNLESS NOTED �, ,,,�''���„���.. '' ,,� R �; E G� .may . (z) . • ,,( NI �# ;. x OWTS. SEE SHEET C-2.0 10, RECOMMENDED LOCATION OF OWTS PUMP CONTROL BOX I INSTALL PUMP CONTROL BOX IN LINE OF SITE WITH TANK m ELECTRICIAN TO PROVIDE CIRCUITS & WIRES FOR PUMPS Ca) Design flow Qd = 6*75=450 gpd OTHERWISE. Septic Tank Design: Use a 1250 gallon, two compartment septic tank with abio-tube dosing assembly in 4. INSTALL A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE. the second chamber.. 5. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS ARE WATERTIGHT. �. Q 28377 -d •, . Lr A l R ' �� O / �� �` ' 10' ---- X 47 0.5 & CONTROLS TO CONTROL PANEL. ELECTRICIAN TO 15'ANY Septic Tank Design: Use a 1250 gallon, two compartment septic tank with abio-tube dosing assembly in POTENTIAL PLUMBING LEAKS SHALL BE REPAIRED TO AVOID EXCESSIVE WATER �� -. , , , ,, �s/UNA1- �• ,'` ' CONFIRM WIRE GAUGE SIZE & COORDINATE INSTALLATION ENTERING THE SEPTIC SYSTEM. the second chamber. , �,�`� ,,, r 00* 4 WITH PUMP SUPPLIER/ INSTALLER. 6. THE SEPTIC TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL WATERTIGHT $ $ S Sub Surface Conditions and Testing: x / O RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS POINTS TO THE FINISHED SURFACE 1.0 m w w N, W w w GRADE. Subsurface soil investigations and USDA soil texture method tests were by Sopris Engineering DESIGNED BY PER 04/15/20 ti� performed _ $ $ 12' 6ti on April 6, 2020. The soils in the area of the proposed absorption field were sampled and characterized 7. A SANITARY BAFFLE TEE IS REQUIRED ON THE SEPTIC TANK INLET AND OUTLET. INSTALL THE F- ETC PROPOSED 28' by application of the USDA soil texture method test. The soils were tested to determine the hydraulic INLET AND OUTLET TEES PLUMB AND IN A POSITION TO ALLOW EASY INSPECTION AND DRAWN BY PER 04/17/20 cc p �_ 2-BEDROOM loading rate and to confirm the appropriate absorptive surface level suitable for an intermittent sand MAINTENANCE OF TANK FROM THE TANK RISERS. z $ DWELLING r filter treatment system in native soils. The soils below nil to 3 inches of topsoil consist of medium dense CHECKED BY YTN 04/17/20 FFE: + 0.5' ABOVE FG loamy to loam to 0.3 to 4 feet below the The to be ll f / gravelly sand sandy material surface. soil appears 8. AN EFFLUENT FILTER IS REQUIRED. INSTALL A 4" EFFLUENT FILTER WITH THE TANK OUTLET x consistent across the site. SANITARY TEE OF THE SEPTIC TANK OR APPROPRIATE FILTER SYSTEM WITH A DISCHARGE DATE: APRIL 17, 2020 PUMP ASSEMBLY. THE GRAVITY OR PUMP SYSTEM FILTER SHOULD BE INSPECTED EVERY SIX EXISTING FENCE 1.25" PRESSURIZED The native soils sampled from 1-2 feet below the surface are characterized as a soil type 1 consisting of MONTHS. THE EFFLUENT FILTER SHALL BE MAINTAINED AND CLEANED WHEN THE TANK IS JOB NO. 19219.01 ETC ETC FT MANIFOLD PIPE. c 16' loamysand to sandyloam texture with moderategranular structure. Soils below 2 feet are increasingly g Y PERIODICALLY PUMPED OR AS NECESSARY. INSTALL A SUITABLE EXTENSION ON THE FILTER INSTALL CHAMBER ON ALL END CHAMBERS END CAP 4" GRAVITY SEWER PIPE INSTALL @ 2% FTC PROPOSED WATER SERVICE PIPE rocky becoming R-1 soils with more than 30% rock content smaller than 3/4". This soil has an effective WITH A HANDLE TO BE WITHIN 6" BELOW THE ACCESS LID. loading rate for conventional soil treatment of 0.8 Gal/S.F./day for a level 1 conventional treatment system. Due to limited area, rock content and to optimal treatment an intermittent sand filter is 9. THE TREATMENT BED MUST BE MARKED AND PROTECTED TO PREVENT DAMAGE FROM ONDALE, CO SYSTEM ABSORPTION/TREATMENT FIELD W/ USE USE 30 QUICK-4 IN 3 ROWS WITH 10CHAMBERS ABSORPTION AREA OF 563 S.F. THE CHAMBERS SHALL BE INSTALLED ,X PER x PRESSURE DOSED BED ROW FOR A TOTAL AT LEVEL GRADE. 2 WAY CLEAN OUT FT c L provide recommended. No free water was encountered in excavations on site. Groundwater levels are expected VEHICULAR AND LIVESTOCK TRAFFIC. to be below 10 feet from the existing surface grades. The soils are suitable for the installation of a sand filter treatment bed system that will be fully pressure 10. THE ENTIRE TREATMENT BED SURFACE MUST BE SODDED OR RE -VEGETATED WITH GROUND dosed and utilize 24-inches of washed concrete sand. An additional soil evaluation will be performed COVER. THE BOTTOM OF THE BED TO BE EXCAVATED TO MIN. DEPTH OF 3.5 FEET WITHIN THE FTC during construction to verify the soils in the proposed field excavation and to confirm that appropriate NATIVE GRAVELY LOAMY SAND & BACKFILLED WITH A MINIMUM LAYER. INSTALL WITH A MIN. 12" NATIVE BACKFILL COVER OVER SEPTIC FIELD FINISH SURFACE APPROX. 6" ABOVE 24-INCH SAND FILTER TOP OF CHAMBERS. ADJACENT GRADES. etc, sand filter media is installed. 11. THE TREATMENT BED SURFACE MUST BE CROWNED TO DIVERT SURFACE DRAINAGE AWAY FROM THE BED. I Intermittent Sand Filter Treatment Unit/Absorption System Design: 1 1/4" PVC SCHD-40 CUSTOM PERFORATED PIPE DISTRIBUTION LATERALS. DIA. ORIFICES EVERY 2.0-FEET ALONG THE PIPE & PLACE ON THE TOP DRILL 3/16-INCH OF THE ABSORPTIVE PROPOSED 12' EXISTING GRAVEL FT GRAVEL c 12. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND SEPARATION I The treatment/absorption field is designed based on utilizing the effective Long Term Acceptance Rate DISTANCES FOR THE OWS COMPONENTS. for intermittent filter treatment dosed distribution laterals SAND SURFACE. USE WIRE STAPLES TO SECURE PRESSURE PIPE TO SAND SURFACE. DRIVEWAY & DRIVEWAI (LTAR) an sand system utilizing pressure and I 13. THE BED SHALL BE LEVEL WITH DISTRIBUTION PIPES INSTALLED FOR EQUAL PRESSURE PARKING gravelless chamber units as spray shields.. The new treatment system will consist of a fully pressure dosed ORIENT ORIFICES BETWEEN THE FIRST AND LAST TO SPRAY UPWARD (12 O'CLOCK) AGAINST 12,235 sq. ft. 0.280 acres '` I filter Treatment bed System 24-inch layer filter (ASTM-33, "washed ASTM-33 DISTRIBUTION. INTERIOR OF CHAMBERS. DRILL FIRST AND LAST 3/16" ORIFICES ORIENTED DOWNWARD AT z sand with a of sand BOTH ENDS OF DISTRIBUTION LATERAL TO ALLOW DRAINAGE OF OUT OF PIPE. I I Concrete sand"). 14. THE BED SHALL BE OVER EXCAVATED TO ALLOW PLACEMENT OF THE SPECIFIED SAND FILTER I- x ^ 6 1 [T TREATMENT MEDIA LAYER. THE BOTTOM SURFACE AND SIDEWALLS OF THE TRENCH TO BE Long Term Acceptance Rate (LTAR) CC EXISTING SCARIFIED AND RAKED AS NECESSARY PRIOR TO PLACEMENT OF THE LEVELING SAND. 12" CMP � ' Considering the application of the new state regulation 43: 1 CULVERT T\ Receiving Wastewater Treatment Level 1; loading rate for sand filter is (0.8 gal./S.F./day) for the minimum 15. THE TREATMENT BED SHALL BE CONSTRUCTED WITH CHAMBER UNITS PLACED OVER THE / 6128 c 24" depth of secondary sand treatment media; SPECIFIED SAND LAYER FOR USE AS SPRAY SHEILDS. THE CHAMBERS, SAND AND \ Loading factors; (Table 10-2, dosed application bed = 1.0) w pressure DISTRIBUTION PIPES SHALL BE COVERED WITH FILTER FABRIC TO THE SIDES OF THE etc,EXCAVATION. MACE RESIDENCE LOTS 15-16, BLK 9, CARB TEWATER TREATMENT 3ERMIT APPLICATION - BUILDING f 12' A(sf) = Qd .: A = Area; 6129 LTAR LTAR = 1.0 Gal/S.F./day for secondary sand, ASTM-33, " Concrete sand" 16. THE MINIMUM COVER OVER THE TOP OF THE CHAMBER SPRAY SHIELD UNITS SHALL BE 12 - ROCKFORD DITCH Qd = flow (gal/day) = 450 gpd INCHES NOT TO EXCEED 18". LATERAL SYSTEM L.F.1=1.0 pressure dosing 6128 RECEPTION No. 17. THE BED CHAMBERS WILL BE BACKFILLED TO THE SURFACE WITH EXCAVATED MATERIAL 61ti9 x 23639 A(sf) = 450 gpd x 1.0 = 562.5 S.F. VOID OF ROCKS. THE BACKFILL MATERIAL SHALL NOT EXCEED 3" DIAMETER. A MINIMUM 4" DEPTH OF TOPSOIL IS TO BE PLACED ABOVE THE BACKFILL TO THE FINISH SURFACE GRADE. 0.8 Gal/S.F./day 18. BALL VALVES SIZE PER PLAN SHALL BE INSTALLED ON THE TERMINAL ENDS OF THE 6129 Excavate a single 47 by 12 bed to a maximum 3.5 depth below finish grade. Backfill with 24 inches of ( ) ASTM-33, concrete sand. Install 3 rows of custom perforated 1.25-inch distribution lateral on top of sand PERFORATED DISTRIBUTION PIPE JUST BELOW THE 4" INSPECTION PORTS. layer in the bed and cover with 10 Quick-4 chambers row for use as dose spray shields, as per pressure 19. ALL INSTALLATION OF THE CHAMBER UNITS SHALL BE IN CONFORMANCE WITH THE delineated on the plan. MANUFACTURES INSTALLATION INSTRUCTIONS. I' 6128 6127 X THE ABSORPTION FIELD SHALL BE INSTALLED PER THE REQUIRED SETBACK DISTANCES: 10 feet from any line. X X X X property X X X 25 feet from any potable water supply line. i� 20 feet from any occupied dwelling. �YQ w w 100 feet from any well, spring or cistern. 25 feet from drainage swale or ditches GRAPHIC `ALE WIRE FENCE DISTRIBUTION SYSTEM NOTES: 1. EFFLUENT FROM THE SECONDARY SEPTIC TANK COMPARTMENT WILL FLOW TO THE 10 0 5 10 20 40 THIRD COMPARTMENT THAT HAS A BIO TUBE DOSING BASIN WITH A SIMPLEX HIGH CONNECT 1.25" TRANSPORT LINE HEAD EFFLUENT PUMP ASSEMBLY. EFFLUENT WILL BE EQUALLY DISTRIBUTED TO THE TO 1.25" PRESSURE MANIFOLD. TRANSPORT PIPE INVERT A MIN. TREATMENT BED VIA THE SPECIFIED INDIVIDUAL TRANSPORT LINE TO THE PRESSURE 2" HIGHER THAN INVERT OF MANIFOLD TEE CONNECTION. USE MANIFOLD AT THE HEAD OF THE BED. (SEE PLAN CALLOUTS NOTES) V ( IN FEET) 45°OR 22.5° FITTINGS. Pump Selection fora Pressurized System - single Family Residence Protect J 0 < CO 1 inch = 10 ft. 1.25" SCHD-40 PVC PRESSURE MANIFOLD W/ INDIVIDUAL Mace Residence Pressure dosed sand filte°MNr 2. THE SPECIFIED CUSTOM PERFORATED PRESSURE DISTRIBUTION LATERALS WILL BE INSTALLED BELOW THE CENTER OF THE SPRAY SHEILD CHAMBER ROWS ON THE SAND L ■ � � 1 1 I- 1.25" TEES OR ELBOWS TO 1.25" CUSTOM PERFORATED �❑ LAYER SURFACE. THE DISTRIBUTION PIPES WILL HAVE 3/16" ORIFICES DRILLED AS DISTRIBUTION PIPE DISTRIBUTION1.25 Parameters 1... Q O 1 PF3d15 SPECIFIED AT EQUAL INCREMENTS ALONG THE PIPE. (SEE PLAN CALLOUTS) I Dischargeinches AssTransportort 051 LOT , AMEN ONSITE CHAMBER END CAP Length 6 feet 3. THE DISTRIBUTION SYSTEM SHALL DISTRIBUTE FLOW EVENLY ACROSS THE INTERMITTENT Transport Pipe Class 40 Orenco Systems' Incorporated Transport Line Size 1.25 inches SAND FILTER BED. THE MINIMUM SLOPE OF THE TRANSPORT PIPE FROM THE DOSING Distridevati Valve Model None 'f Max Elevation Lift 5 feet Manifold Length 9 feet CJ'ungerr�rfn• Wily the i�"�ldDuey Wmr�'uuT TANK TO THE PRESSURE MANIFOLD SHALL SHALL BE A MINIMUM 2.5% TO ALLOW FOR DRAIN BACK. ALL DISTRIBUTION PIPING, CONNECTIONS AND FITTINGS SHALL BE 250 Gallon Top Seam - 2CP z.a Manifold Pipe Class 40 WATERTIGHT AND INSTALLED TO INSURE EQUAL DISTRIBUTION THROUGH THE SYSTEM. HAM �WV 1 " Manifold Pipe Size 1 25 inches High Head �3 - Number of Laterals per Cell 3 J PF�,� with . Lateral Length a2 feet ELECTRICAL NOTES 1250T-2CP-HHPump Lateral Pipe Class 40 - - �- 1. AN ORENCO SYSTEMS CONTROL PANEL SHALL BE INSTALLED BY A QUALIFIED INSTALLER \ \ \ TYPICAL YARD LANSCAPED SURFACE Lateral Pipe Size 1.25 inches \�j/j� orifice Size 3i66 inches IN COORDINATION WITH THE ELECTRICIAN. WE RECOMMEND 110 VOLT ELECTRIC / A // OR AGGREATE PAVED SURFACE orifice Spacing 2.5 feet SERVICE BE PROVIDED TO THE PUMP. THE POWER SUPPLY FOR THE PUMPS AND 6" MIN. "'� Residual Head 2 feet Z90 Flow Meter None inches PFaw� \ CONTROLS SHALL CONSIST OF (1) 20 AMP DOUBLE POLE CIRCUITS FOR THE PUMP AND Top EXCAVATEDO90% MATERIAL COMPACTED i 10 AMP SINGLE POLE CIRCUITS FOR CONTROLS. PANELS TO BE INSTALLED IN LINE OF . r TO STANDARD PROCTOR Add -on Friction Losses 0 feet m - - SITE WITH TANK AND OR PUMP BASINS. DESIGN NOTES .' .. View • Design test ASTM �.:� �, ' Calculations E - per performance per C1227 �f/�' . Minimum Flow Rate per Orifice 0.62 gpm I"' 2. THE CONTRACTOR SHALL INSTALL ELECTRICAL SUPPLY WIRE IN CONDUIT FROM THE • Top surface area 56.25 ft° 20"CIMrM(�Ms 4 �� SUITABLE BACKFILL OR CLASS 6 ROAD BASE Number of Orifices per Zone 51 Total Flow Rate per Zone 31.9 gpm m p SERVICE PANEL TO THE WALL MOUNTED CONTROL PANEL. • f c 0 28 days; concrete = 6,000 PSI Min. F>f1" / 1 = w Number of Laterals per Zone 3 u �5 Flow Differential 1st/Last Drifce 5.3 3. THE SYSTEM QUALIFIED INSTALLER SHALL INSTALL ELECTRICAL DIRECT BURY WIRES OR Installation: \� y 4 E WIRES IN CONDUIT FROM THE CONTROL PANEL(S) TO THE DISCHARGE PUMP • Tank to be set on 5" min. sand I; I TransportVelocity 6.9 fps bed YANK 4 c ASSEMBLY'S JUNCTION BOX ON THE RESPECTIVE RISERS OVER THE TANK OR BASINS. or peo gravel Frictional Head Losses , PF30el INSTALL CODED WIRES PER CONTROL PANEL DIAGRAM. INSTALL ALL WIRES FOR PUMP • Tank to be backfilled uniformly on all sides in lifts less than 24" and ID 1I I TRENCH CROSS-SECTION F 0 R Loss through Discharge 7.1 feet AND CONTROLS WITH CONDUIT SEAL NEAR SPLICE BOX. ELECTRICIAN TO COORDINATE mechanically compacted , . , , I2- Loss in Transport 0.7 feet - -.. W/ SYSTEM INSTALLER. INSTALLATION CONSULTATION BY VALLEY PRECAST, INC. • Excavated material may be used for SDR - 3 5 H D P E 0 R SC H E D - 40 PIPES Loss through Valve 0.0 feet - - , , ins bockfill, provided large stones are Less in Manifold 03 feet TESTING, INSPECTIONS AND CONSTRUCTION MANAGEMENT removed • Excavation should be dewatered and 24" Minimum Riser Height N.T.S. Loss in Laterals 03 feet Loss through Flowmeter 0 0 feet tank filled with water prior to being put in service for installation with / -Add-or' Friction Losses 110 feet \ \ 1. ADDITIONAL INSPECTIONS AND RECOMMENDATION WILL BE MADE BY THE ENGINEER water table less than 2' below grade Who P al'', Iil Sal 1 as mat DURING CONSTRUCTION TO APPROVE THE LAYOUT OF THE TREATMENT FIELD SYSTEM, • Meets C1644-06 for resilient „ connectors Pak. i1 r CROWN FIELD TRENCH TO MAINTAIN SUITABLE VEGETATIVE COVER Vol of Transport Line 0.5 gals • Inlet and Outlet identified above pipe I�OOt • Delivered complete with internal piping �" / -, �� DIVERT SURFACE WATER Vol of Manifold 0.7 gals Vol of Laterals per Zone 9.8 gals `-y`«^•c,«'= - 2. PRIOR TO CONSTRUCTION OF THE PERMITTED SYSTEM THE ENGINEER SHOULD BE • Control Panel to be mounted in sight .+.• a_... = •."' ::' �- •' " r, cr• Total Volume 10.9 gals ; mocL,,, CONTACTED BY THE PROJECT MANAGER/CONTRACTOR WELL IN ADVANCE TO PROVIDE line of tank sip Rubber I TOPSOIL 1.25"SCHD-40 PVC ADEQUATE TIME TO DISCUSS THE SYSTEM COMPONENTS WITH THE CONTRACTOR, + 4' Maximum bury depth a - GRADE DISTRIBUTION MANIFOLD Minimum Re Requirements Pump q °'°'"3; a= a - ANSWER QUESTIONS, RESOLVE ANY CONFLICT ISSUES AND SCHEDULE INSPECTION SITE Sward ,� ��EXISTING dMh ` 19" Design Flow Rate .9 gpm Wirers aPs-.t: VISITS BASED ON CONSTRUCTION PROGRESS. A PRE-OWS CONSTRUCTION MEETING WITH DATE REVISION 11 Total Dynamic Head 1515.4 feet THE ENGINEER, THE CONTRACTOR,FIED INSTALLER IS c�=yr r°,.. 0 - + '' r - r - ° 5 10 15 20 25 as 0 REQUIRED PRIOR TO ON OF THE OWTS COMPONENTS. aj j j j 12' 8" Net Discharge (gpm) 00/00/00 XXX --'" "T ; -:49" = 54' .:: ;::;: :;:;: ....� _ _ =e= _ f 1.50' (TYP.) MIN. MAX.1 3. REGULATIONS REQUIRE THAT THE DESIGN ENGINEER OF RECORD PERFORM SITE ALLOWABLE BURY Water Table) • �� e= %; • • e-* e-� �• p.S' (TYP.) 1 IAS-BUILTNDOCUMENTATION (Based on �e !. - OF THE SYSTEMTOHOE THE COUNTY AFTER r a- 1.0'(TYP.) 7'` 24" WATER TABLE ALLOWABLE EARTH FILL jd !- ��f. -- / , , I CONSTRUCTION IS COMPLETE. WE RECOMMEND THAT INSTALLED OWS COMPONENTS BE �, • ... = 1 ' �.je'/ i SURVEYED TO OBTAIN REQUIRED AS -BUILT INFORMATION. a' - O. Z' - a" ` _ 130" - aryl =:= 14,4 \ GENERAL NOTES: t' - 0" 3' - 0" Section UNDISTURBED EARTH 4. CONTRACTOR SHOULD DISCUSS ISSUES REGARDING SPECIFICATIONS, INSTALLATION AND 2' 0" 3' 0" View ► 1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING. OPERATION OF OWTS MECHANICAL SYSTEMS AND CONTROLS WITH THE 3 - 0' _ 4. - 0 SCREENED BACKFILL 36" COSTUME PERFORATED PRESSURE PIPE WITH SUPPLIER/INSTALLER AND/OR THE ENGINEER. DRY 4. - a" ■ Lowers l•SSand Improves effluent NATIVE SOIL 1.25" TEE CONNECTION ORIFICES AT 12 O'CLOCK 2. THE PROPOSED LOT CONDITIONS AND SURVEY INFORMATION BY SOPRIS ENGINEERING AND OTHERS 5. OUR DESIGN AND RECOMMENDATIONS ARE BASED UPON OUR EVALUATION OF THE quality to1Ield R 3. THE EXISITNG LOT CONDITIONS PER COUNTY GIS DATA BASE, AERIAL MAPPING, LIDAR TOPOGRAPHY AND e Complete InetelletIon � g� per SECURE PIPE WITH PUSH IN STAPLES EXISTING AND PROPOSED SITE CONDITIONS AND INFORMATION SUPPLIED TO US BY INTERMITTENT SAND FILTER LAYER EFFECTIVE SIZE SURVEY INFORMATION BY SOPRIS ENGINEERING 0.25-0.6 MM, WITH UNIFORM. COEF.=<4.0 USE OTHERS. IF SITE CONDITIONS ARE FOUND TO BE DIFFERENT FROM CONDITIONS ASSUMED mount and -up procedures) QUICK-4 INFILTRATOR OR INDICATED, WE SHOULD BE NOTIFIED TO EVALUATE ANY EFFECT ON THE PROPOSED 'Service oontracte available far maintenance'• \ \ / / / i� /// /// /// /// /// /// // OR EQUAL BIO DIFFUSER \\ \ \ \ \ \ \ \ \ \ ���\ SPRAY SHIELDS ��\ ��\ ��\��\��\��\��\��\��\�� / CONCRETE SAND-ASTM-33 4. PRIMARY OWNER NAME AND ADDRESS: MACE, DAVID DYLAN OWTS. MACHINE COMPACT AND LEVEL TOP SURFACE 88 CEDAR ST Digging Specs Invert Dimensions Net Capacity Net Weight ��\ \� CARBONDALE, CO 81623 Min. 13' Long x 7' Wide Inlet Outlet Length Width Height Inlet Side Outlet Total Lid Tank Total PRESSURE DISTRIBUTION PIPE CONNECTED THROUGH END CAP 12'-MIN. 5. LEGAL SUMMARY: COOPERTON TWNSTE. BLOCK: 9 LOT: 15 AND 16 INCLUDES LOT D ASSESSOR PARCEL 2393-284-09-020 NATIVE GRAVELLY LOAMY SAND SOIL 56" below inlet 56" 54"or73" 135" 80" 92" 843 gal 415 gal 1259 gal 3120 Ihs 10880 lbw 114200 Ibs NOTE: WITH COBBLES ADDRESS: TO CUSTOM PERFORATED DISTRIBUTION THE INTERMITTENT SAND FILTER BED MUST BE LEVEL. INSTALL CHAMBERS WITH INLET AND 6. SITE ADDRESS: 88 CEDAR ST, CARBONDALE, CO 81623 TBD CEDAR STREET LATERAL PIPE END CAPS OVER SAND LAYERT FOR USE AS SPRAY SHEILDS. INSTALL INDIVIDUAL VACANT LAND DISTRIBUTION LATERALS TO THE HEAD OF EACH CHAMBER ROW FROM A MAINIFOLD 7. Parcel Number: 239328409015 TITLE SCARIFY/TILL BOTTOM SURFACE AND CONNECTING EACH CHAMBER ROW. CUSTOM PERFORATED PIPE TO BE LAID ON TOP OF 8. GARFIELD COUNTY PERMIT #: ISSUED EXCAVATION SIDE WALLS THE SAND LAYER WITH ORIFICES ORIENTED UPWARD EXCEPT THE FIRST AND LAST ORIFICES OWTS DESIGN Phone: 719-395-6764 WVALLEY TO BE ORIENTED DOWNWARD. INSTALL A 4" VERTICAL INSPECTION RISER FROM THE MOLDED CUT OUT ON THE LAST CHAMBER IN EACH ROW. INSTALL A BALL VALVE AT THE 9. CONTRACTOR: CONSTRUCTION PLAN Fax: 719-395-3727 inc. A��� www.vEdleyprecast.com PRECAST,GYP END OF THE DISTRIBUTION LINE ACCESSIBLE FROM THE INSPECTION PORT TO ALLOW \ ip r FLUSHING OF THE LINE. THE VALVE IS CLOSED FOR NORMAL OPERATION. Buena vista, Colorado Email: esk@w'I mca oom PRH„S'SURN,' DOSH,''D INTI'RMITTI'NT SAND I II,TH,'R SYSTI/M Know what's below. DRAWING NO. Call before dig. you WITH CIIAAIBH, R SPRAY SIII, fll,I�,S' CALL 2-BUSINESS DAYS IN ADVANCE C-2.0 BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MFMBFR UTILITIES