Loading...
HomeMy WebLinkAboutMechanical Compliance Certificate 04.29.2020irdt 1 COMcheck Software Version 4.1.1.0 Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: County Rd 331 Colorado River Road Silt, CO 81652 Additional Efficiency Package(s) Unspecified 2015 IECC Silt Farms Rifle, Colorado 5b New Construction Owner/Agent: Charles Barr Designer/Contractor: Wesley Ploof BG Buildingworks 1626 Cole Blvd, Suite 300 Golden, CO 80401 3032783820 wgploof@bgbuildingworks.com Mechanical Systems List Quantity System Type & Description 2 F-1,2 (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 110 kBtu/h Proposed Efficiency = 93.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Split System, Capacity = 60 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 16.00 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 1800 CFM, 0.8 motor nameplate hp, 0.0 fan efficiency grade 1 F-3 (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 110 kBtu/h Proposed Efficiency = 93.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Split System, Capacity = 60 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency = 16.00 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 2 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Constant Volume, 2000 CFM, 0.8 motor nameplate hp, 0.0 fan efficiency grade 22 UH -1 (Single Zone): Heating: 1 each - Unit Heater, Gas, Capacity = 8600 kBtu/h Proposed Efficiency = 80.00% Ec, Required Efficiency: 80.00 % Ec Fan System: FAN SYSTEM 3 -- Compliance (Brake HP method) : Passes Fans: FAN 3 Supply, Constant Volume, 495 CFM, 0.0 motor nameplate hp, 0.0 design brake hp (0.0 max. BHP), 0.0 fan efficiency grade 2 UH -2,4 (Single Zone): Heating: 1 each - Unit Heater, Gas, Capacity = 23 kBtu/h Proposed Efficiency = 80.00% Ec, Required Efficiency: 80.00 % Ec Fan System: FAN SYSTEM 4 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 5 Supply, Constant Volume, 750 CFM, 0.1 motor nameplate hp, 0.0 fan efficiency grade Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 1 of 17 Quantity System Type & Description 1 UH -3 (Single Zone): Heating: 1 each - Unit Heater, Gas, Capacity = 5 kBtu/h Proposed Efficiency = 80.00% Ec, Required Efficiency: 80.00 % Ec Fan System: FAN SYSTEM 5 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 6 Supply, Constant Volume, 270 CFM, 0.1 motor nameplate hp, 0.0 fan efficiency grade 1 UH -5 (Single Zone): Heating: 1 each - Unit Heater, Gas, Capacity = 21 kBtu/h Proposed Efficiency = 80.00% Ec, Required Efficiency: 80.00 % Ec Fan System: FAN SYSTEM 6 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 7 Supply, Constant Volume, 1200 CFM, 0.1 motor nameplate hp, 0.0 fan efficiency grade 2 UH -7 (Single Zone): Heating: 1 each - Unit Heater, Electric, Capacity = 10 kBtu/h No minimum efficiency requirement applies Fan System: FAN SYSTEM 7 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 8 Supply, Constant Volume, 350 CFM, 0.0 motor nameplate hp, 0.0 fan efficiency grade 2 Plant 1: Heating: Hot Water Boiler, Capacity 4000 kBtu/h, Gas Proposed Efficiency: 93.00 % Ec, Required Efficiency: 82.00 % Ec 1 WH -3: Gas Instantaneous Water Heater, Capacity: 0 gallons, Input Rating: 75 kBtu/h w/ Circulation Pump Proposed Efficiency: 93.00 EF, Required Efficiency: 0.62 EF 1 WH -1: Gas Storage Water Heater, Capacity: 100 gallons, Input Rating: 250 kBtu/h w/ Circulation Pump Proposed Efficiency: 96.00 % Et, Required Efficiency: 80.00 % Et Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Silt Farms Report date: 04/29/20 Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Page 2 of 17 rft. v COMcheck Software Version 4.1.1.0 II Inspection Checklist Energy Code: 2015 IECC Requirements: 85.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.ID Plan Review Complies? Comments/Assumptions C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. •Complies •Does Not Not Observable •Not Applicable C103.2 [PR3]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. ❑Complies •Does Not Not Observable • Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. •Complies ❑Does Not •Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 3 of 17 C403.2.4. 5, C403.2.4. 6 [FO9]3 Footing / Foundation Inspection Snow/ice melting system sensors for future connection to controls. Freeze protection systems have automatic controls installed. ❑ Complies ❑ Does Not ❑ Not Observable ❑ Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 4 of 17 Section # & Req.ID Plumbing Rough -In Inspection Complies? Comments/Assumptions C404.5, Heated water supply piping conforms •Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume •Does Not C404.5.2 requirements. Refer to section details. •Not Observable [PL6]3 •Not Applicable C404.5, Heated water supply piping conforms •Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume •Does Not C404.5.2 [PL6] requirements. Refer to section details.• Not Observable •Not Applicable C404.5, Heated water supply piping conforms •Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume •Does Not C404.5.2 requirements. Refer to section details. •Not Observable [PL6]3 •Not Applicable C404.5, Heated water supply piping conforms •Complies C404.5.1, to pipe length and volume •Does Not C404.5.2 requirements. Refer to section details. •Not Observable [PL6]3 •Not Applicable C404.5, i Heated water supply piping conforms •Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume I■Does Not C404.5.2 requirements. Refer to section details. MI Not Observable [PL6]3 I■Not Applicable C404.5, Heated water supply piping conforms •Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume •Does Not C404.5.2 requirements. Refer to section details. ■Not Observable [PL6]3 •Not Applicable C404.5, Heated water supply piping conforms •Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume •Does Not C404.5.2 requirements. Refer to section details. , ■Not Observable [PL6]3 •Not Applicable C404.5, Heated water supply piping conforms ,•Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume '•Does Not C404.5.2 requirements. Refer to section details. •Not Observable [PL6]3 •Not Applicable C404.5, Heated water supply piping conforms •Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. •Not Observable [PL6]3 ■Not Applicable C404.5, Heated water supply piping conforms •Complies Requirement will be met. C404.5.1, to pipe length and volume •Does Not C404.5.2 requirements. Refer to section details. Location on plans/spec: PLumbing floorplans Not Observable •[PL613 ❑Not Applicable C404.6.1, Automatic time switches installed to I■Complies Exception: Requirement does not apply. C404.6.2 automatically switch off the ■ Does Not [PL3]1 recirculating hot-water system or heat• trace. Not Observable •Not Applicable 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 5 of 17 Section # & Req.ID Plumbing Rough -In Inspection Complies? Comments/Assumptions C404.6.1, Automatic time switches installed to •Complies Requirement will be met. C404.6.2 automatically switch off the ■ Does Not [PL3]1 recirculating hot-water system or heat trace. Location on plans/spec: M4.1 ■Not Observable ■Not Applicable C404.6.3 Pumps that circulate water between a •Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls thatlimit m start •Does Not ■Not Observable <= 5 minutes after end of heating •Not Applicable cycle. C404.6.3 Pumpsthat circulateoperationfrowater betweenupto a ■Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to ■ Does Not ■ Not Observable <= 5 minutes after end of heating •Not Applicable :cycle. C404.6.3 Pumps that circulate water between a •Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to ■ Does Not ■Not Observable <= 5 minutes after end of heating cycle. •Not Applicable C404.6.3 Pumps that circulate water between a •Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to •Does Not •Not Observable <= 5 minutes after end of heating cycle. •Not Applicable C404.6.3 Pumps that circulate water between a ,■Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to ■ Does Not •Not Observable <= 5 minutes after end of heating cycle. ■Not Applicable C404.6.3 Pumps that circulate water between a •Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to •Does Not •Not Observable <= 5 minutes after end of heating cycle. •Not Applicable C404.6.3 Pumps that circulate water between a •Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to •Does Not •Not Observable <= 5 minutes after end of heating cycle. ■ Not Applicable C404.6.3 Pumps that circulate water between a■Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to •Does Not •Not Observable <= 5 minutes after end of heating cycle. ; ■Not Applicable C404.6.3 Pumps that circulate water between a •Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to ■ Does Not •Not Observable <= 5 minutes after end of heating cycle. ■Not Applicable C404.6.3 Pumps that circulate water between a •Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls that limit operation from startup to •Does Not ■Not Observable <= 5 minutes after end of heating cycle. •Not Applicable ; 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 6 of 17 Section # & Req.ID Plumbing Rough -In Inspection Complies? Comments/Assumptions C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. •Complies Exception: Requirement does not apply. •Does Not •Not Observable I■ Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. ❑Complies Exception: Requirement does not apply. •Does Not •Not Observable • Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. •Complies Exception: Requirement does not apply. •Does Not •Not Observable • Not Applicable •Complies C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. Exception: Requirement does not apply. •Does Not •Not Observable I Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. •Complies •Does Not •Not Observable • Not Applicable 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 7 of 17 Section # & Req.ID Plumbing Rough -In Inspection Complies? Comments/Assumptions C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. •Complies Exception: Requirement does not apply. •Does Not •Not Observable I■ Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. ❑Complies Exception: Requirement does not apply. •Does Not •Not Observable • Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. •Complies Exception: Requirement does not apply. •Does Not •Not Observable • Not Applicable •Complies C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. Exception: Requirement does not apply. •Does Not •Not Observable I Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. •Complies Exception: Requirement does not apply. •Does Not •Not Observable • Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 8 of 17 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) _1 3 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 9 of 17 Section # & Req.ID Mechanical Rough -In Inspection Complies? Comments/Assumptions C402.2.6 Thermally ineffective panel surfaces of [ME41]3 sensible heating panels have insulation >= R-3.5. •Complies Exception: Requirement does not apply. •Does Not •Not Observable ■Not Applicable C403.2.13 :Unenclosed spaces that are heated [ME71]2 Iuse only radiant heat. I •Complies Exception: Requirement does not apply. •Does Not •Not Observable ■Not Applicable C403.2.3 [ME55]2 HVAC equipment efficiency verified. •Complies See the Mechanical Systems list for values. •Does Not •Not Observable •Not Applicable C403.2.4. 7 [ME113]2 Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. •Complies Exception: Requirement does not apply. 1 •Does Not •Not Observable ■Not Applicable C403.2.4. 7 [ME113]2 Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. •Complies Exception: Requirement does not apply. •Does Not •Not Observable •Not Applicable C403.2.6. 1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outsidepp air damper control, or design airflow >3,000 cfm. •Complies Exception: Requirement does not apply. ■ Does Not ■Not Observable •Not Applicable e C403.2.6. 2 [ME115]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. •Complies Exception: Requirement does not apply. •Does Not •Not Observable •Not Applicable C403.2.7 [ME57]1 Exhaust air energy recovery on systems meeting Table C403.2.7(1) and C403.2.7(2). •Complies Exception: Requirement does not apply. •Does Not •Not Observable •Not Applicable C403.2.8 Kitchen exhaust systems comply with [ME116]3 replacement air and conditioned lesupply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. •Complies •Does Not •Not Obsvable erlirvble ■ Not A pp C403.2.9 HVAC ducts and plenums insulated. [ME60]2 Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. •Complies Exception: Requirement does not apply. •Does Not •Not Observable ; ■ Not Applicable C403.2.9 Ducts and plenums sealed based on [ME10]2 static pressure and location. ;■Complies Requirement will be met. Location on plans/spec: MP0.1 •Does Not ❑Not Observable ❑Not Applicable C403.2.9. Ductwork operating >3 in. water 1.3 column requires air leakage testing. [ME11]3 •Complies Exception: Requirement does not apply. •Does Not ❑Not Observable •Not Applicable 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 10 of 17 Section & Req.ID C403.2.9. 1.3 [ME11]3 C403.2.9. 1.3 [ME11]3 C403.2.9. 1.3 [ME11]3 C403.2.9. 1.3 [ME11]3 C403.2.9. 1.3 [ME11]3 C403.2.9. 1.3 [ME11]3 C403.3 [ME62]1 Mechanical Rough -In Inspection Ductwork operating >3 in. water column requires air leakage testing. Complies? ❑ Complies ❑ Does Not [Not Observable E Not Applicable Comments/Assumptions Exception: Requirement does not apply. Ductwork operating >3 in. water column requires air leakage testing. ❑ Complies ❑ Does Not [Not Observable E Not Applicable Exception: Requirement does not apply. Ductwork operating >3 in. water column requires air leakage testing. ❑ Complies Exception: Requirement does not apply. ❑ Does Not [Not Observable E Not Applicable Ductwork operating >3 in. water column requires air leakage testing. ❑ Complies Exception: Requirement does not apply. ❑ Does Not ['Not Observable E Not Applicable Ductwork operating >3 in. water column requires air leakage testing. Ductwork operating >3 in. water column requires air leakage testing. ❑ Complies ❑ Does Not ['Not Observable E Not Applicable ❑ Complies ❑ Does Not ❑ Not Observable E Not Applicable Exception: Requirement does not apply. Exception: Requirement does not apply. Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. ❑ Complies ▪ Does Not ['Not Observable ENot Applicable Requirement will be met. Location on plans/spec: Mechanical Floorplans and schedules C403.3 [ME62]1 C403.4.2 [ME69]3 C403.4.2. 4 [ME68]3 C403.4.2. 5 [ME107]3 Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. ❑ Complies ❑ Does Not Requirement will be met. Location on plans/spec: mechanical schedules and floor ❑Not Observable plans ENot Applicable Temperature reset by representative building loads in pumping systems for chiller and boiler systems >500,000 Btu/h. ❑ Complies ❑ Does Not ['Not Observable E Not Applicable Requirement will be met. Location on plans/spec: M4.1 Hydronic systems greater than 500,000 Btu/h designed for variable fluid flow. ❑ Complies ❑ Does Not [Not Observable E Not Applicable Requirement will be met. Location on plans/spec: M4.1 System turndown requirement met through multiple single -input boilers, one or more modulating boilers, or a combination of single -input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtu/h has 3:1 turndown ratio, boiler input between 5.0 MBtu/h and 10 MBtu/h has 4:1 turndown ratio, boiler input > 10.0 MBtu/h has 5:1 turndown ratio. ❑ Complies Requirement will be met. ❑ Does Not ['Not Observable Location on plans/spec: MO.1, M4.1 E Not Applicable See the Mechanical Systems list for values. 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 11 of 17 Section # & Req.ID Mechanical Rough -In Inspection Complies? Comments/Assumptions C403.4.4. Multiple zone VAV systems with DDC •Complies Exception: Requirement does not apply. 6 of individual zone boxes have static •Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. ■Not Observable ■Not Applicable C403.4.4. Multiple zone VAV systems with DDC •Complies Exception: Requirement does not apply. 6 of individual zone boxes have static •Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. •Not Observable •Not Applicable C403.4.4. Multiple zone VAV systems with DDC •Complies Exception: Requirement does not apply. 6 of individual zone boxes have static •Does Not [ME110 3 pressure setpoint reset controls. See the Mechanical Systems list for values. •Not Observable ■Not Applicable; C403.4.4. Multiple zone VAV systems with DDC •Complies Exception: Requirement does not apply. 6 of individual zone boxes have static •Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. •Not Observable •Not Applicable C403.4.4. Multiple zone VAV systems with DDC •Complies Exception: Requirement does not apply. 6 of individual zone boxes have static •Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. •Not Observable •Not Applicable C403.4.4. Multiple zone VAV systems with DDC •Complies Exception: Requirement does not apply. 6 of individual zone boxes have static •Does Not [ME110]3 pressure setpoint reset controls. ❑Not Observable See the Mechanical Systems list for values. •Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies Exception: Requirement does not apply. 6 of individual zone boxes have static •Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. •Not Observable •Not Applicable C404.2.1 Gas-fired water -heating equipment •Complies Requirement will be met. [ME111]z installed in new buildings: where a singular piece of water -heating equipment >= 1,000 kBtu/h serves the entire building, thermal efficiency •Does Not •Not Observable •Not Applicable >= 90 Et. Where multiple pieces of water -heating equipment serve the building with combined rating >= 1,000 kBtu/h, the combined input - capacity -weighted -average thermal efficiency >= 90 Et. Exclude input rating of equipment in individual dwelling units and equipment <= 100 kBtu/h. C408.2.2. Air outlets and zone terminal devices ❑Complies Requirement will be met. 1 have means for air balancing. ❑Does Not [ME53]3 Location on plans/spec: Mechanical Floorplans •Not Observable •Not Applicable C403.5, Refrigerated display cases, walk-in ❑Complies Requirement will be met. C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote •Not Observable [ME123]3 condensers not located in a condensing unit, have fan -powered condensers that comply with Sections ❑Not Applicable C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 12 of 17 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) _1 3 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 13 of 17 C403.2.4. 1 [F147]3 • Section & Req.ID C303.3, C408.2.5. 3 [F18]3 C403.2.2 [F127]3 C403.2.4. 1 [F147]3 C403.2.4. 1 [F147]3 C403.2.4. 1 [F147]3 C403.2.4. 1 [F147]3 C403.2.4. 1 [F147]3J C403.2.4. 1 [F147]3 C403.2.4. 1.2 [F138]3 C403.2.4. 1.3 [F120]3 Final Inspection Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies? ❑ Complies ❑ Does Not [Not Observable ❑ Not Applicable Comments/Assumptions HVAC systems and equipment capacity does not exceed calculated loads. ❑ Complies ❑ Does Not ❑ Not Observable ❑ Not Applicable Requirement will be met. Location on plans/spec: Mechanical Schedules Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. ❑ Complies E Does Not ❑ Not Observable ❑ Not Applicable Requirement will be met. Location on plans/spec: Mechanical Floorplans Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. ❑Complies '❑Does Not ['Not Observable ❑Not Applicable Requirement will be met. Location on plans/spec: mefchanical floorplans ❑Complies ▪ Does Not ['Not Observable ▪ Not Applicable Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Requirement will be met. Location on plans/spec: mechanical floorplans ❑Complies ❑ Does Not ❑ Not Observable ❑Not Applicable Requirement will be met. Location on plans/spec: mechanical floorplans Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. E Complies ❑ Does Not ❑Not Observable ❑ Not Applicable Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Requirement will be met. Location on plans/spec: mechanical floorplans ❑ Complies ❑ Does Not ❑ Not Observable ❑ Not Applicable Requirement will be met. Location on plans/spec: mechanical floorplans Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. ❑ Complies ❑ Does Not ❑ Not Observable ❑ Not Applicable Requirement will be met. Location on plans/spec: Mechanical Floor plans Thermostatic controls have a 5 °F deadband. ❑Complies Requirement will be met. '❑Does Not ❑Not Observable Location on plans/spec: M4.1 ❑ Not Applicable Temperature controls have setpoint overlap restrictions. ❑ Complies ❑ Does Not [Not Observable ❑ Not Applicable Requirement will be met. 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 14 of 17 Section # & Req.ID Final Inspection Complies? Comments/Assumptions C403.2.4. Each zone equipped with setback •Complies ; Requirement will be met. 2 controls using automatic time clock or •Does Not [F139]3 programmable control system. •Not Observable •Not Applicable C403.2.4. Automatic Controls: Setback to 55°F •Complies Requirement will be met. 2.1, (heat) and 85°F (cool); 7 -day clock, 2- •Does Not C403.2.4. hour occupant override, 10 -hour •Not Observable 2.2 backup •Not Applicable [F140]3 C403.2.4. Systems include optimum start •Complies Exception: Requirement does not apply. 2.3 controls. ❑Does Not [F141]3 •Not Observable •Not Applicable C403.2.4. Systems include optimum start •Complies Exception: Requirement does not apply. 2.3 controls. •Does Not [F141]3 •Not Observable •Not Applicable C403.2.4. Systems include optimum start •Complies Exception: Requirement does not apply. 2.3 controls. •Does Not [F141]3 •Not Observable ■Not Applicable C403.2.4. Systems include optimum start •Complies Exception: Requirement does not apply. 2.3 controls. •Does Not [F141]3 •Not Observable •Not Applicable C403.2.4. Systems include optimum start •Complies Exception: Requirement does not apply. 2.3 controls. •Does Not [F141]3 ■Not Observable •Not Applicable C403.2.4. Systems include optimum start •Complies Exception: Requirement does not apply. 2.3 controls. •Does Not [F141]3 •Not Observable •Not Applicable C403.2.4. Systems include optimum start •Complies Exception: Requirement does not apply. 2.3 controls. •Does Not [F141]3 •Not Observable •Not Applicable C404.3 Heat traps installed on supply and •Complies Exception: Requirement does not apply. [FI11]3 discharge piping of non -circulating systems. •Does Not •Not Observable •Not Applicable C404.3 Heat traps installed on supply and ■Complies Exception: Requirement does not apply. [FI11]3 discharge piping of non -circulating systems. ❑Does Not •Not Observable ■Not Applicable i C404.4 All piping insulated in accordance with •Complies Requirement will be met. [F125]2 section details and Table C403.2.10. •Does Not Location on plans/spec: MP0.1 •Not Observable ■Not Applicable 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 15 of 17 Section # & Req.ID Final Inspection Complies? Comments/Assumptions C404.4 [F125]2 All piping insulated in accordance with section details and Table C403.2.10. •Complies Requirement will be met. Location on plans/spec: MP0.1 •Does Not ■Not Observable ■Not Applicable C404.6.1 Controls are installed that limit the •Complies Exception: Requirement does not apply. [F112]3 operation of a recirculation pump installed to maintain temperature of a storage tank. System return pipe is a dedicated return pipe or a cold water supply pipe. •Does Not •Not Observable •Not Applicable C404.6.1 Controls are installed that limit the •Complies Requirement will be met. [F112]3 operation of a recirculation pump •Does Not installed to maintain temperature of a storage tank. System return pipe is a dedicated return pipe or a cold water supply pipe. Location on plans/spec: M4.1 •Not Observable ■ Not Applicable pp e C408.2.1 Commissioning plan developed by •Complies [F128]1 registered design professional or approved agency. •Does Not •Not Observable ■Not Applicable C408.2.3. HVAC equipment has been tested to •Complies 1 ensure proper operation. •Does Not [F131]1 •Not Observable •Not Applicable C408.2.3. HVAC control systems have been •Complies 2 tested to ensure proper operation, ■ Does Not [F110]1 calibration and adjustment of controls. •Not Observable •Not Applicable C408.2.3. Economizers have been tested to •Complies 3 ensure proper operation. •Does Not [F132]1 •Not Observable •Not Applicable C408.2.4 Preliminary commissioning report•■Complies [F129]' completed and certified by registered design professional or approved agency. ❑Does Not •Not Observable ■ Not Applicable C408.2.5. Furnished HVAC as -built drawings •Complies 1 submitted within 90 days of system ❑Does Not [F17]3 acceptance. •Not Observable •Not Applicable C408.2.5. An air and/or hydronic system •Complies 3 balancing report is provided for HVAC •Does Not [F143]1 systems. •Not Observable •Not Applicable C408.2.5. Final commissioning report due to •Complies 4 building owner within 90 days of ■ Does Not [F130]1 receipt of certificate of occupancy. •Not Observable •Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 'Medium Impact (Tier 2) 13 I Low Impact (Tier 3) Project Title: Silt Farms Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Report date: 04/29/20 Page 16 of 17 Project Title: Silt Farms Report date: 04/29/20 Data filename: S:\BGProjects\10120.00 Silt Farms Indoor Cultivation Facility\Engineering\Mechanical\Calculations\Silt Farms - ComCheck.cck Page 17 of 17