Loading...
HomeMy WebLinkAboutPermitGarfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT-6275 Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 05/21/2020 Expiration Date 05/21/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable. Project Address: 0109 Oakland Knoll Glenwood Springs, CO 81601 Parcel No.: 2395-222-02-022 Owner Name: Matthew and Sarah Cova Owner Phone: (530) 306-7265 Designed By: High Country Engineering, Inc. Designer Phone: (970) 945-8676 Number of Bedrooms 5 Minimum Tank Capacity 1,500 gal Minimum Absorption 1,260 ft2 Permit Conditions: This OWTS Permit is approved on the condition of compliance with the application and design documents as submitted by High Country Engineering, Inc. dated May 21, 2020. Changes must be approved by Garfield County Public Health and the designer prior to construction. The repaired OWTS will serve a five -bedroom house. The system will consist of an existing 1,250- gallon septic tank, followed by a 500-gallon pump chamber with a dosing pump, followed by an automatic distributing valve set level and to grade at the high point of the system to distribute effluent to 1,275 square feet of Soil Treatment Area (STA). The STA consists of 5 trenches of 17 ARC ADS chambers per trench (85 total) with flushing valves at the end of the trenches. Distribution laterals will be 1.5" diameter hung from the underside of the chambers, with 3/16" orifice holes every 4 feet on -center. 1 drain hole pointing down will be provided on each end of the lateral. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of th1system will be issued. • P/ i 1 , `f ✓ �ry /' -t 5/21/2020 a Issued By: Garfield County Environmental Health Department Date