HomeMy WebLinkAboutPermitCGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT-6259
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 06/15/2020 Expiration Date 06/15/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable.
Project Address: 1188 County Road 106 Carbondale, CO 81623 Parcel No.: 2393-283-08-015
Owner Name: Michael Hayes and Sydney Schalit Owner Phone: (970) 309-5006
Designed By: Carla Ostberg of CBO, INC. Designer Phone: (970) 309-5259
Number of Bedrooms 3 Minimum Tank Capacity 1,250 gal Minimum Absorption 562.5 SF
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the application and design
documents as submitted by CBO, INC. dated April 18, 2020. Changes must be approved by Garfield
County Public Health and the designer prior to construction.
The following variance requests presented in the design documents and report by CBO, Inc. have
been granted by the Board of Health without a public hearing.
1. Decrease of setback from existing well to septic tank from 50 feet to 40 feet.
2. Decrease of setback from existing well to STA from 100 feet to 46 feet.
3. Decrease of setback from STA to dwelling (with crawlspace) from 20 feet to 11 feet.
4. Decrease of setback from STA to property line from 10 feet to 1 foot.
The repaired OWTS will serve a three -bedroom house. The system will consist of a new precast
concrete 1,250-gallon septic tank set level with access to grade and a high head pump in the second
chamber to distribute effluent to a new Soil Treatment Area (STA). The new STA will consist of a
minimum three -feet deep unlined sand filter, utilizing a secondary sand filter material. A control
panel for the pump will be placed within sight of the pump. Maintain all setbacks and elevations as
designed, per variance request approval.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval ofthe system will be issued.
j
6/15/2020
Issued By: Garfield County Environmental Health
Department
Date