HomeMy WebLinkAboutOWTS Construction Planc 6;\2019\19219\CIVIL D W US W t\19 L19-Ut-U W IJ VERHEAD ILITY LINES 0 z EXISTING OVERHEAD ELECTRIC EXISTING FENCE CO M 0 0 0 z ROPERTY LIN % INSTALL 4" RISER PIPE INSPECTION PORT AT I EACH END CHAMBER (TVP.) 1.25" FLUSH BALL VALVE ON END OF EACH DISTRIBUTION LATERAL TALL ASSEMBLY BELOW EACH INSPECTION cryT (TVP. END EA. ROW) OWTS. SEE SHEET C-2.0 PRESSURE DOSE TRANSPORT PIPE. USE 1.25 SCHD-40 W/ 3.0' MIN. DEPTH OF BURY. BED PIPE WI CL -6 ROAD BASE. INSTALL AT MIN. 2.5% TO ALLOW DRAIN BACK TO TANK. W m 10' N 89°22'00" W X INSTALL CHAMBER END CAP ON ALL END CHAMBERS 47 0.5 10' 12 ABSORPTION/TREATMENT FIELD WI PRESSURE DOSED BED USE USE 30 QUICK -4 IN 3 ROWS WITH 10CHAMBERS PER ROW FOR A TOTAL ABSORPTION AREA OF 563 S.F. THE CHAMBERS SHALL BE INSTALLED AT LEVEL GRADE. THE BOTTOM OF THE BED TO BE EXCAVATED TO MIN. DEPTH OF 3.5 FEET WITHIN THE NATIVE GRAVELY LOAMY SAND & BACKFILLED WITH A MINIMUM 24 -INCH SAND FILTER LAYER. INSTALL WITH A MIN. 12" NATIVE BACKFILL COVER OVER TOP OF CHAMBERS. SEPTIC FIELD FINISH SURFACE APPROX MABOVE ADJACENT GRADES. 71 I ^ I \ 1 1/4" PVC SCHD-40 CUSTOM PERFORATED PIPE DISTRI BUTT®LATERALS. DRILL 3/16 -INCH DIA. ORIFICES EVERY 2.0 -FEET ALONG THE PIPE & PLACE ON jIETOPOFTHEABSORPTIVE SAND SURFACE. USE WIRE STAPLES TO SECURE PRE$StIRE PIPE TO SAND SURFACE. ORIENT ORIFICES BETWEEN THE FIRST AND LAST TO SPRAY UPM4RD (12 O'CLOCK) AGAINST _ INTERIOR OF CHAMBERS. DRILL FIRST AND LAST 3/16" ORIFICE9IORIENTED DOWNWARD AT BOTH ENDS OF DISTRIBUTION LATERAL TO ALL09KDRAINAGE OF OUT OF PIPE. 10 x z 1.25" PRESSURIZED MANIFOLD PIPE. 4" GRAVITY SEWER PIPE INSTALL @ 2% 2 -WAY CLEAN OUT INSTALL 2 -COMPARTMENT 1250 -GALLON CONCRETE SEPTIC TANK (VALLEY PRECAST ITEM # 1250t-2CP-HH) INSTALL WITH (2) 24" DIA. BY 24" DEEP RIBBED PVC RISERS W/ LIDS AT THE SURFACE. INSTALL ORENCO SIMPLEX EFFLUENT PUMP ASSEMBLY. (PVU57-1819-L) W/P300511 PUMP), WI 1.25" DISCHARGE ASSEMBLIES. DEPTH TO TOP OF TANK FROM PROPOSED GRADE IS APPROX. 2'. INSTALL UNDERGROUND ELECTRICAL & CONTROL DIRECT BURY UV WIRES OR WIRES IN CONDUIT FOR PUMPS WITHIN SEWER PIPE TRENCH & CONTROLS. RECOMMENDED LOCATION OF OWTS PUMP CONTROL BOX INSTALL PUMP CONTROL BOX IN LINE OF SITE WITH TANK ELECTRICIAN TO PROVIDE CIRCUITS & WIRES FOR PUMPS & CONTROLS TO CONTROL PANEL ELECTRICIAN TO PROPOSED CONFIRM WIRE GAUGE SIZE & COORDINATE INSTALLATION GRAVEL Jr w WITH PUMP SUPPLIER/ INSTALLER. ETC ASSUMED LOCATION ELECTRIC SERVICE PANEL ETc ETC W �•� w ----BRIVEWAY W PROPOSED 2 -BEDROOM DWELLING FFE: + 0.5' ABOVE FG PROPOSED WATER SERVICE W ETC ETC ETC ETC GRAPHIC SCALE 0 5 10 20 40 ( IN FEET ) 1 inch = 10 ft. 1250 Gallon Top Seam - 2CP Item # 1250T-2CP-HH with High Head Pump DESIGN NOTES • Design per performance test per ASTM C1227 • Top surface area 56.25 ft° • tc 0 28 days; concrete - 6.000 PSI Mln. Installation • Tank to be set on 5" min. sand bed or pea gravel • Tonk to be bockfilled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet identified above pipe • Delivered complete with internal piping • Control Panel to be mounted in sight line of tank • 4' Maximum bury depth ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 2'-0" 3' - 0" 4'-0" DRY 4'- 0' 60" Top View 24" Minimum Riser Height 'Service contracts available for maintenance' Digging Specs Invert 13' Long x 7' Wide Inlet Outlet 56" below inlet Section View Pump: • Lowers TSS and improves effluent quality to fleld • Complete installation (wiring, panel, nauntiftg and startup procedures) • Complete warranty Dimensions Net Capacity Min. Length Width Height! Inlet Side Out Total et Weight Lid Tank Total 56" 54'or73" 135" 60" 92" 843 gal 416 gal 1259 gal 3120 lbs 10880 lbs 14200 lbs O VALLEY L7 PRECAST, Inc. Buena Vista, Colorado Phone: 719-395-6764 Fax 719-395-3727 Weblike: www.valleyprecastcom Email: finntdesl valleyprecastoom PROPERTY LI " (TYP) x x x ROCKFORD DITCH LATERAL SYSTEM x CONNECT 1.25" TRANSPORT LINE TO 1.25" PRESSURE MANIFOLD. TRANSPORT PIPE INVERTA MIN. 2" HIGHER THAN INVERT OF MANIFOLD TEE CONNECTION. USE 45°OR 22.5° FITTINGS. 1.25" SCHD-40 PVC PRESSURE MANIFOLD W/ INDIVIDUAL 1.25" TEES OR ELBOWS TO 1.25" CUSTOM PERFORATED DISTRIBUTION PIPE UNDISTURBED EARTH SCREENED BACKFILL NATIVE SOIL CHAMBER END CAP 6" MIN. rrAFSAr I 1 PAA A TYPICAL YARD LANSCAPED SURFACE OR AGGREATE PAVED SURFACE EXCAVATED MATERIAL COMPACTED TO 90% STANDARD PROCTOR SUITABLE BACKFILL OR CLASS 6 ROAD BASE TRENCH CROSS-SECTION FOR SDR -.35 x HDPE OR SCHED-40 PIPES N.T.S. CROWN FIELD TRENCH TO DIVERT SURFACE WATER EXISTING GRADE TOPSOIL SEED AND MULCH FINISH SURFACE MAINTAIN SUITABLE VEGETATIVE COVER ETC x EXISTING w w Design Calculations OWTS Design Calculations OWTS Installation of an OWTS with a minimum 3 -bedroom capacity. From County adopted State Regulation 43: Minimum population based on 3 bedrooms = 6 persons. First 3 bedrooms (2 persons/bedroom) Over 3 bedrooms (1 person per bedroom) Gallons per day per person =75 gal/person/day, No peaking factor Max. Design flow (Qd)gallons/day = (N of people) x (avg. flow)gal/person/day. Design flow Qd = 6`75=450 gpd Septic Tank Design: Use a 1250 gallon, two compartment septic tank with a bio -tube dosing assembly in the second chamber.. Septic Tank Design: Use a 1250 gallon, two compartment septic tank with a bio -tube dosing assembly in the second chamber. Sub Surface Conditions and Testing: Subsurface soil investigations and USDA soil texture method tests were performed by Sopris Engineering on April 6, 2020. The soils in the area of the proposed absorption field were sampled and characterized by application of the USDA soil texture method test. The soils were tested to determine the hydraulic loading rate and to confirm the appropriate absorptive surface level suitable for an intermittent sand filter treatment system in native soils. The soils below nil to 3 inches of topsoil consist of medium dense gravelly loamy sand to sandy loam material to 0.3 to 4 feet below the surface. The soil appears to be consistent across the site. The native soils sampled from 1-2 feet below the surface are characterized as a soil 1 consisting 8 of loamy sand to sandy loam texture with moderate granular structure. Soils below 2 feet are increasingly rocky becoming R-1 soils with more than 30% rock content smaller than 3/4". This soil has an effective loading rate for conventional soil treatment of 0.8 Gal/S.F./day for a level 1 conventional treatment system. Due to limited area, rock content and to provide optimal treatment an intermittent sand filter is recommended. No free water was encountered in excavations on site. Groundwater levels are expected to be below 10 feet from the existing surface grades. The soils are suitable for the installation of a sand filter treatment bed system that will be fully pressure dosed and utilize 24 -inches of washed concrete sand. An additional soil evaluation will be performed during construction to verify the soils in the proposed field excavation and to confirm that appropriate sand filter media is installed. Intermittent Sand Filter Treatment Unit/ Absorption System Design: The treatment/absorption field is designed based on utilizing the effective Long Term Acceptance Rate (LTAR) for an intermittent sand filter treatment system utilizing pressure dosed distribution laterals and gravelless chamber units as spray shields.. The new treatment system will consist of a fully pressure dosed sand filter Treatment bed System with a 24 -inch layer of filter sand (ASTM -33, "washed ASTM -33 Concrete sand"). Long Term Acceptance Rate (LTAR) Considering the application of the new state regulation 43: Receiving Wastewater Treatment Level 1; loading rate for sand filter is (0.8 gal./S.F./day) for the minimum 24" depth of secondary sand treatment media; Loading factors; (Table 10-2, pressure dosed application bed = 1.0 ) A(sf) = Qd .: A = Area; LTAR LTAR = 1.0 Gal/S.F./day for secondary sand, ASTM -33, " Concrete sand" Qd = flow (gal/day) = 450 gpd L.F.1=1.0 pressure dosing A(sf) = 450 gpd x 1.0 = 562.5 S.F. 0.8 Gal/S.F./day Excavate a single 47' by 12' bed to a maximum 3.5' depth below finish grade. Backfill with 24 -inches of ASTM -33, concrete sand. Install 3 rows of custom perforated 1.25 -inch distribution lateral on top of sand layer in the bed and cover with 10 Quick -4 chambers per row for use as pressure dose spray shields, as delineated on the plan. OWTS SYSTEM NOTES 1. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO STATE AND COUNTY ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATIONS. 2. Fr IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND EXCAVATION. 3. ALL SEWER LINES TO BE SDR -35 BEDDED IN CLASS 6, SDR -26 BEDDED IN SCREENED NATIVE OR SCHEDULE 40 P.V.C. PIPE BEDDED IN SCREENED NATIVE MATERIAL UNLESS NOTED OTHERWISE. 4. INSTALL A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE. 5. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS ARE WATERTIGHT. ANY POTENTIAL PLUMBING LEAKS SHALL BE REPAIRED TO AVOID EXCESSIVE WATER ENTERING THE SEPTIC SYSTEM. 6. THE SEPTIC TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS POINTS TO THE FINISHED SURFACE GRADE. 7. A SANITARY BAFFLE TEE IS REQUIRED ON THE SEPTIC TANK INLET AND OUTLET. INSTALL THE INLET AND OUTLET TEES PLUMB AND IN A POSITION TO ALLOW EASY INSPECTION AND MAINTENANCE OF TANK FROM THE TANK RISERS. 8. AN EFFLUENT FILTER IS REQUIRED. INSTALL A 4" EFFLUENT FILTER WITH THE TANK OUTLET SANITARY TEE OF THE SEPTIC TANK OR APPROPRIATE FILTER SYSTEM WITH A DISCHARGE S PECTE D EVERY SIX PUMP ASSEMBLY. THE GRAVITY OR PUMP SYSTEM FILTER SHOULD BEI INSPECTED MONTHS. THE EFFLUENT FILTER SHALL BE MAINTAINED AND CLEANED WHEN THE TANK IS PERIODICALLY PUMPED OR AS NECESSARY. INSTALL A SUITABLE EXTENSION ON THE FILTER WITH A HANDLE TO BE WITHIN 6" BELOW THE ACCESS LID. 9. THE TREATMENT BED MUST BE MARKED AND PROTECTED TO PREVENT DAMAGE FROM VEHICULAR AND LIVESTOCK TRAFFIC. 10. THE ENTIRE TREATMENT BED SURFACE MUST BE SODDED OR RE -VEGETATED WITH GROUND COVER. 11. THE TREATMENT BED SURFACE MUST BE CROWNED TO DIVERT SURFACE DRAINAGE AWAY FROM THE BED. 12. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND SEPARATION DISTANCES FOR THE OWS COMPONENTS. 13. THE BED SHALL BE LEVEL WITH DISTRIBUTION PIPES INSTALLED FOR EQUAL PRESSURE DISTRIBUTION. 14. THE BED SHALL BE OVER EXCAVATED TO ALLOW PLACEMENT OF THE SPECIFIED SAND FILTER TREATMENT MEDIA LAYER. THE BOTTOM SURFACE AND SIDE WALLS OF THE TRENCH TO BE SCARIFIED AND RAKED AS NECESSARY PRIOR TO PLACEMENT OF THE LEVELING SAND. 15. THE TREATMENT BED SHALL BE CONSTRUCTED WFTH CHAMBER UNITS PLACED OVER THE SPECIFIED SAND LAYER FOR USE AS SPRAY SHEILDS. THE CHAMBERS, SAND AND DISTRIBUTION PIPES SHALL BE COVERED WITH FILTER FABRIC TO THE SIDES OF THE EXCAVATION. 16. THE MINIMUM COVER OVER THE TOP OF THE CHAMBER SPRAY SHIELD UNITS SHALL BE 12 INCHES NOT TO EXCEED 18". 17. THE BED CHAMBERS WILL BE BACKFILLED TO THE SURFACE WITH EXCAVATED MATERIAL VOID OF ROCKS. THE BACKFILL MATERIAL SHALL NOT EXCEED 3" DIAMETER. A MINIMUM 4" DEPTH OF TOPSOIL IS TO BE PLACED ABOVE THE BACKFILL TO THE FINISH SURFACE GRADE. 18. BALL VALVES (SIZE PER PLAN) SHALL BE INSTALLED ON THE TERMINAL ENDS OF THE PERFORATED DISTRIBUTION PIPE JUST BELOW THE 4" INSPECTION PORTS, 19. ALL INSTALLATION OF THE CHAMBER UNITS SHALL BE IN CONFORMANCE WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS. 1.25" SCHD-40 PVC DISTRIBUTION MANIFOLD - i.S" ITYP.I _ tatIYP.) ; /,. bk e1 \tel-•' lsw QUICK -4 INFILTRATOR OR EQUAL BIO DIFFUSER SPRAY SHIELDS PRESSURE DISTRIBUTION PIPE CONNECTED THROUGH END CAP TO CUSTOM PERFORATED DISTRIBUTION LATERAL PIPE SCARIFY/TILL BOTTOM SURFACE AND EXCAVATION SIDE WALLS SECU STAP 12" -18" MIN. IMAX. - 0(5' (TYP.) 24" 1.25" TEE CONNECTION RE PIPE WITH PUSH IN LES 12' -MIN. 36" NOTE: THE INTERMITTENT SAND FILTER BED MUST BE LEVEL. INSTALL CHAMBERS W TH INLET AND END CAPS OVER SAND LAYERT FOR USE AS SPRAY SHEILDS. INSTALL INDIVIDUAL DISTRIBUTION LATERALS TO THE HEAD OF EACH CHAMBER ROW FROM A MA NIFOLD CONNECTING EACH CHAMBER ROW. CUSTOM PERFORATED PIPE TO BE LAID ON TOP OF THE SAND LAYER WITH ORIFICES ORIENTED UPWARD EXCEPT THE FIRST AND LAST ORIFICES TO BE ORIENTED DOWNWARD. INSTALL A 4" VERTICAL INSPECTION RISER FROM THE MOLDED CUT OUT ON THE LAST CHAMBER IN EACH ROW. INSTALL A BALL VALVE AT THE END OF THE DISTRIBUTION LINE ACCESSIBLE FROM THE INSPECTION PORT TO ALLOW FLUSHING OF THE LINE. THE VALVE IS CLOSED FOR NORMAL OPERATION. Pump Selection for a Pressurized System - single fR05101155ty Resce Project BRAND RESIDENCE I FULLPRE t IRE DOSE SAND FILTER Parameters Discharge Assemlw Size Transpad Lenoth Transport Pipe Class Transport Una Size Distributing Valve Model Max Elevation Lin Manifold Lengtt. Manifold Pipe Class Manifold Pipe Size Number of Laterals per Cell Lateral Length Lateral Pipe Class Lateral Pipe Size Orifice Size Orifice Spacing Residual Head Flow Meter 'Adson• Fndion Losses Calcufatlans 125 inches 10 feet 40 125 Inches None 5 feet 9 feet 40 125. inches 3 33 feet 40 125 Inches 3118 inches 2 feet 2 feet None Inches 0 feet Minimum Flow Rale perQrifice 0.62 Spm Numberaf orifices per Zone Si Total FlowRale per 201M 31.8 qpm Number of Laterals perZone 3 %Flow -Deferential 1st/Last alike. 4.9 % Transpoaveladh 8.9 fps. Frictional Mead Losses Loss Waugh Discharge Loss In Transport Loss through Vane Loss In Manifold Loss in Laterals Loss through Flowmatei Aid -on' Faction Losses. Pipe Volumes 7-1 1.4 0.0 0.4 0.2 0.0 0.0 feet feet feet feet feet feet lest. Vol of Transport Line 0B'. gals Vol of Manifold '07 gals Vol of Laterals per Zone 7.7 gals Total Volume 9,2. gals Minimum Pump Requirements Design Flow Rate 310 qpm Total Dynamic Head 16,.1 feet poppiorto II 1111111111111 iiirnooiImiiuiIi! 111111111 Ito mllphavin6iimpa= 100 to 20 25 Net Discharge (qpm) CB Oreetc Systems* Incorporated Chi y'x to Way dr Wade tela wu Veenuxe %sew cows Tapcure aa s: naw oa•„Ray- 0555150": ps• Pas® Pw 0 O CUSTUME PERFORATED PRESSURE PIPE WITH ORIFICES AT 12 O'CLOCK INTERMITTENT SAND FILTER LAYER EFFECTIVE SIZE 0.25-0.6 MM, WITH UNIFORM. COEF.=<4.0 USE CONCRETE SAND -ASTM -33 MACHINE COMPACT AND LEVEL TOP SURFACE NATIVE GRAVELLY LOAMY SAND SOIL WITH COBBLES PRESSURE DOSED INTERMITTENT SAND FILTER SYSTEM WITH CHAMBER SPRAY SHF, ILDS GENERAL NOTES: 1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING. 2. THE PROPOSED LOT CONDITIONS AND SURVEY INFORMATION BY SOPRIS ENGINEERING. 3. PRIMARY OWNER NAME AND ADDRESS: BRAND, KEITH & CARRIE 1327 WEST RIDGE COURT ,CARBONDALE, CO 81623 4. Legal Summary Quarter: SECTION: 28 TOWNSHIP: 7 RANGE: 88 SUBDIVISION: COOPERTON TWNSTE. BLOCK: 9 LOT: 12 THRU:- LOT: 14 10875 SQUARE FEET 5. SITE ADDRESS: TBD CEDAR STREET, CARBONDALE, CO 81623 6. Parcel Number: 2393-284-09-020 7. GARFIELD COUNTY PERMIT it ISSUED 8. CONTRACTOR: THE ABSORPTION FIELD SHALL BE INSTALLED PER THE REQUIRED SETBACK DISTANCES: 10 feet from any property line. 25 feet from any potable water supply line. 20 feet from any occupied dwelling. 100 feet from any well, spring or cistern. 25 feet from drainage swale or ditches DISTRIBUTION SYSTEM NOTES: 1. EFFLUENT FROM THE SECONDARY SEPTIC TANK COMPARTMENT WILL FLOW TO THE THIRD COMPARTMENT THAT HAS A 810 TUBE DOSING BASIN WITH A SIMPLEX HIGH HEAD EFFLUENT PUMP ASSEMBLY. EFFLUENT WILL BE EQUALLY DISTRIBUTED TO THE TREATMENT BED VIA THE SPECIFIED INDIVIDUAL TRANSPORT LINE TO THE PRESSURE MANIFOLD AT THE HEAD OF THE BED. (SEE PLAN CALLOUTS NOTES) 2. THE SPECIFIED CUSTOM PERFORATED PRESSURE DISTRIBUTION LATERALS WILL BE INSTALLED BELOW THE CENTER OF THE SPRAY SHEILD CHAMBER ROWS ON THE SAND LAYER SURFACE. THE DISTRIBUTION PIPES WILL HAVE 3/16" ORIFICES DRILLED AS SPECIFIED AT EQUAL INCREMENTS ALONG THE PIPE. (SEE PLAN CALLOUTS) 3. THE DISTRIBUTION SYSTEM SHALL DISTRIBUTE FLOW EVENLY ACROSS THE INTERMITTENT SAND FILTER BED. THE MINIMUM SLOPE OF THE TRANSPORT PIPE FROM THE DOSING TANK TO THE PRESSURE MANIFOLD SHALL SHALL BE A MINIMUM 2.5% TO ALLOW FOR DRAIN BACK. ALL DISTRIBUTION PIPING, CONNECTIONS AND FITTINGS SHALL BE WATERTIGHT AND INSTALLED TO INSURE EQUAL DISTRIBUTION THROUGH THE SYSTEM. ELECTRICAL NOTES 1. AN ORENCO SYSTEMS CONTROL PANEL SHALL BE INSTALLED BY A QUALIFIED INSTALLER IN COORDINATION WITH THE ELECTRICIAN. WE RECOMMEND 110 VOLT ELECTRIC SERVICE BE PROVIDED TO THE PUMP. THE POWER SUPPLY FOR THE PUMPS AND CONTROLS SHALL CONSIST OF (1) 20 AMP DOUBLE POLE CIRCUITS FOR THE PUMP AND 10 AMP SINGLE POLE CIRCUITS FORCONTROLS. PANELS TO BE INSTALLED IN LINE OF SITE WITH TANK AND OR PUMP BASINS. 2. THE CONTRACTOR SHALL INSTALL ELECTRICAL SUPPLY WIRE IN CONDUIT FROM THE SERVICE PANEL TO THE WALL MOUNTED CONTROL PANEL. BURY WIRES OR 3. THE SYSTEM QUALIFIED INSTALLER SHALL INSTALL ELECTRICAL DIRECT B U WIRES IN CONDUIT FROM THE CONTROL PANEL(S) TO THE DISCHARGE PUMP ASSEMBLY'S JUNCTION BOX ON THE RESPECTIVE RISERS OVER THE TANK OR BASINS. INSTALL CODED WIRES PER CONTROL PANEL DIAGRAM. INSTALL ALL WIRES FOR PUMP AND CONTROLS WITH CONDUIT SEAL NEAR SPLICE BOX. ELECTRICIAN TO COORDINATE W/ SYSTEM INSTALLER. INSTALLATION CONSULTATION BY VALLEY PRECAST, INC. TESTING, INSPECTIONS AND CONSTRUCTION MANAGEMENT 1. ADDITIONAL INSPECTIONS AND RECOMMENDATION WILL BE MADE BY THE ENGINEER DURING CONSTRUCTION TO APPROVE THE LAYOUT OF THE TREATMENT FIELD SYSTEM, VERIFY INSTALLATION OF SPECIFIED MATERIALS AND OWTS COMPONENTS. 2. PRIOR TO CONSTRUCTION OF THE PERMITTED SYSTEM THE ENGINEER SHOULD BE CONTACTED BY THE PROJECT MANAGER/CONTRACTOR WELL IN ADVANCE TO PROVIDE ADEQUATE TIME TO DISCUSS THE SYSTEM COMPONENTS WITH THE CONTRACTOR, ANSWER QUESTIONS, RESOLVE ANY CONFLICT ISSUES AND SCHEDULE INSPECTION SITE VISITS BASED ON CONSTRUCTION PROGRESS. A PRE-OWS CONSTRUCTION MEETING WITH THE ENGINEER, THE CONTRACTOR, ELECTRICIAN AND THE QUALIFIED INSTALLER IS REQUIRED PRIOR TO INSTALLATION OF THE OWTS COMPONENTS. 3. REGULATIONS REQUIRE THAT THE DESIGN ENGINEER OF RECORD PERFORM SITE INSPECTIONS OF THE PERMITTED SYSTEM DURING CONSTRUCTION AND PROVIDE "AS -BUILT" DOCUMENTATION OF THE INSTALLED SYSTEM TO THE THE COUNTY AFTER CONSTRUCTION IS COMPLETE. WE RECOMMEND THAT INSTALLED OWS COMPONENTS BE SURVEYED TO OBTAIN REQUIRED AS -BUILT INFORMATION. 4. CONTRACTOR SHOULD DISCUSS ISSUES REGARDING SPECIFICATIONS, INSTALLATION AND OPERATION OF OWTS MECHANICAL SYSTEMS AND CONTROLS WITH THE SUPPLIER/INSTALLER AND/OR THE ENGINEER. 5. OUR DESIGN AND RECOMMENDATIONS ARE BASED UPON OUR EVALUATION OF THE EXISTING AND PROPOSED SITE CONDITIONS SAND INFORMATION SUPPLIED TO US BY OTHERS. IF SITE CONDITIONS ARE FOUND TO BE DIFFERENT FROM CONDITIONS ASSUMED OR INDICATED, WE SHOULD BE NOTIFIED TO EVALUATE ANY EFFECT ON THE PROPOSED OWTS. S OPRIS ENGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 DESIGNED BY PER 05/31/18 DRAWN BY PER 05/31/18 CHECKED BY PER 05/31/18 DATE: 2018-05-18 JOB NO. 19219 0 0 al 2 W F_ ifl � Z 00M 0) W�/ I__LL Fu w U 2 LLI Z Q Y WCO �/ 10 03 to W r < Q W 2 0 ``1- w iL LLI 0 Z � W Q Z O 0 OWTS PERMIT APPLICATION - BUILDING PERMIT I I DATE REVISION ASSESSOR PARCEL 2393-284-09-020 ADDRESS: TBD CEDAR STREET VACANT LAND 00/00/00 XXX Know what's below. Call before you dig. CALL 2 -BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILI•FS TITLE OWTS DESIGN CONSTRUCTION PLAN DRAWING NO C-2.0