Loading...
HomeMy WebLinkAboutAs-built Report 08.10.2020From: Jeff Simonson To: Lindsay Krol; Jody Daniels Subject: [External] RE: Final As -built letter for Lot 7, Quicksilver Ct. Date: Monday, August 10, 2020 12:32:18 PM Attachments: Lot 7 As Built.pdf Hi Lindsay, Please let this letter and the attached as -built serve as an installation report. Please note that following our follow up with the contractor/owner as well as an onsite investigation of the observed construction, we have determined that the project has been completed in general compliance of our design of the OWTS for Lot 7, Quicksilver Court. Notable modifications to the installation are that the trench alignments were rotated 90 degrees to follow the existing topography from design. Also, the as -built now locates the size of the modular home with the location of the OWTS components relative to the location of the home. We have attached the as built drawing accordingly. Please call with any questions or if further information is needed. Respectfully, Jefferey S. Simonson, P.E. Principal 6SGM 118 W Sixth St, Suite 200 Glenwood Springs, CO 81601 970.384.9005 / 970.379.4691 cell www, s9m-i nc. corn From: Lindsay Krol <Ikrol@garfield-county.com> Sent: Friday, August 7, 2020 12:09 PM To: Jody Daniels <ghdgrowit@aol.com> Cc: Jeff Simonson <JeffS@sgm-inc.com> Subject: Final As -built letter for Lot 7, Quicksilver Ct. Jody We need a final letter of installation/ as -built report from your engineer before we can close out septic permit number SEPT -03-20-6177 and issue the certificate of occupancy for building permit number BLMF-03-20-6176. Please email a copy so we can close out these two permits and issue your C.O. Thank you, Lindsay Krol Garfield County — Community Development Admin. Asst. II & Safety Committee Rep. 108 8th St., Ste. 401 Glenwood Springs, CO 81601 970-945-8212 0 0 0 0 a) mZ Q N ed: 8/10/2020 r 11. NOTE: POLYLOK WEIRS OF TRENCHES. IS (SEE Per 0 10 lLSEPTIC 3 Graphic 20 t Scale 40 1 Ir II SOUTH PROPERTY LINE OF LOT 6 AND NORTH PROPERTY LINE OF LOT 7 4" DIA. SOL/D WALL DISTRIBUTION SLOPED AT M/N. FROM DISTRIBUTION INFILTRATOR 7 OUTLET EQUAL BOX WITH SLIDE PVC ASTM 1/4" PER FLOW DISTRIBUTIONG�\ IN BAFFLE 3034 LINES FOOT BOX TO TRENCH 37 o_ 00 `L BUILDING 5 LOT 7B MAIN HOME / EFFLUENT LINE FROM TANK (4" PVC 0 1/4" PER FOOT MIN. SLOPE, USE PVC ASTM SOLID WALL PIPE) TO DISTRIBUTION BOX ;�� a 1000 CONC. SEPTIC 3 BEDROOM HOME -off OL � � ' 0 g o TANK OF PER FOOT 0. EAST G c.,; �Qcy o Jz �s F2 a PROPER INSPECTION PORT, TYP 0 0 0 g • .0 0 ' g0 , 0 k�' . u RAW SEWAGE LINE FROM HOME (4" PVC ® 1/4" MIN. SLOPE, USE PVC ASTM SOLID WALL PIPE) CLEAN OUT In Feet: 1" = 20' IT IS RECOMMENDED THAT (OR EQUAL) FLOW DISTRIBUTION BE INSTALLED ON THE OUTLET EACH PIPE TO THE INFILTRATOR IT IS CRITICAL THAT FLOW EQUALLY DISTRIBUTED TO EACH TRENCH PRODUCT DETAIL ON SHEET 4) As -built 8/10/2020 ILC by Curran SGM 118 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 970.945.1004 www.sgm-inc.com Garfield Count Colorado County, Daniels Residence S 22 , TbN, R93WRifleCO , , OWTS Design and Details GRAVITY SYSTEM 2019292.001 1 Drawn by: JSS Date: 07/03/19' OC: PE: JSS Of Lot 7 H2 File: Daniels -LOT 7ASBUILT ome Revision Date By 1 0 0 0 0 .0 00 Is—LOT 7 AS BUILT.dwg P 0) m H—Dwgs Ci vil B 92—✓odyDoni 0 N 2.3' Knock Down Baffle Top ./iew 1.2' 1.0' End /iew 2.3' 2.1' Section /iew 2.3' Lid /iew 7 Outlet Equal Flow Distribution Box with Silde—/n Baffle • 4000 PSI Concrete • 4" Pipe penetration ports • Connectors cast into the box As -Built 8/10/20 QUICK4 STANDARD MULTIPORT END CAP 4" PVC FROM HOUSE /FOOT MIN. SLOPE ASSURE EXISTING RISER FOR PUMP ACCESS I VIII mIIIWIII III VIII III IIIA III I' • ASSURE EXIST/NG RISER FOR PUMP ACCESS Al a 4 4 PROVIDE TRAFFIC RATED LID /F /T IS ANTICIPATED THAT VEHICLES WILL TRAVEL OVER SEPTIC TANK n d n Tough engineered plastic. Will not corrode. Installs without tools. Adjustment knob moves opening up or down in 1/16" increments: total movement is 7/8"'_ f i Simple to install. just push into any 4" pipe. SCH. 40, SDR 35, and thin wall. Water tight fit POL YL OK PRODUCT DETAIL 1000 GAL. OR 1250 GAL. SEPTIC TANK 6SGM 118 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 970.945.1004 www.sgm-inc.com NOT TO SCALE 4" SOLID WALL 3034 PVC PIPE AT 1/4 %FOOT SLOPE (MIM) TO DISTRIBUTION BOX PROVIDE AN EFFLUENT FILTER ON DISCHARGE SIDE OF SEPTIC TANK IF NONE CURRENTLY EXISTS Garfield County, Colorado Daniels Residence S 22, T6N, R93W, Rifle, CO MOUND FOR PROPER DRAINAGE NATIVE BACKFILL INFILTRATOR SYSTEMS INC. QUICK4 STANDARD CHAMBER 0 52" INSPECTION PORT ESTABLISH VEGETATIVE COVER 8' MAX BUR/AL DEPTH 72" MIN., H-10 LOAD AREAS 6" MIN., NON—TRAFFIC AREAS 34" 36" QU/CK4 CHAMBER TIBER TYPICAL INSTALLATION DETAIL (Not to Scale) 12" PIPE CAP, TYP 4" OBSERVATION PIPE, TYP NATIVE BACKFILL, TYP IN—SITU SOIL, TYP INFILTRATOR QU/CK4 GRA VELLESS CHAMBER EXCA VA TION 6' MIN (10' SHOWN) EXISTING GRADE n 6" DIA. PVC PIPE SLEEVE 3' (TYP) QUICK4 TRENCH DETAIL NOT TO SCALE OWTS Design and Details GRAVITY SYSTEM DETAIL SHEET I NOTE: IF OVER 48" IN DEPTH, PROVIDE AN A/R VENT TO EACH TRENCH IN LIEU OF OBSERVATION PORT A/R VENT TO EXTEND 36" ABOVE ADJACENT FIN/SH GRADE Job No. 2019-292.001 Drawn by: JSS Date: 07/03/19 QC: - PE: JSS File: Daniels -LOT 7 AS BUILT Of 2 2