Inspection Report
Date: 9-3-20
Project: Piccione Residence
Address: 1213 CR 112 Carbondale, CO
Building Permit No: BLMF-12-19-6075
Contractor that Performed Work: Tally Ho Construction & Others
Inspection of shop fabrication or field work at job site: Field
Report: Inspected high strength A325 bolting at the four main frame column &
rafter connections roof framing.
The high strength A325 bolting inspected above appeared to be in substantial
conformance with the plans & the AISC/RCSC Specification for high strength
bolting.
Also inspected high strength A325 bolting at the steel beam & column
connections upper floor framing. Bolts were all installed & tightened, but the
plans onsite did not show the steel beam extending for the full length of the
building & there did not appear to be a detail for the beam splice connection.