HomeMy WebLinkAboutCertificate of Insulation 04.06.2020EnergyPro Insulation, Inc
l'U fiu.t 21416 Cimiid function_ CO 81502 Witco 970-623-7 27
Certificate of Insulation
The undersigned certifies that the listed insulation products have been installed in
e manufacturer's recommended applications for these Products
R-Value
Material
Work Area
Notes
R-38
Unfaced fiberglass bait
Upper level vaulted/
breakfast nook
Install to the upper level vaulted and to
the ceiling of the breakfast nook.
R-38
Unfaced Fiberglass Batt
Ceiling area
Installed at non-blowable areas.
R-38
Loose -fill Fiberglass
Ceiling Area
Install an average depth of 13" to the
ceiling area
R-30
Unfaced fiberglass batt
Garage with living above
Install to the garage with living above
R-24
Dense Pack Fiberglass
Exterior Walls
Installed to the exterior walls of the
house.
R-21
Unfaced Fiberglass Batt
Garage Exterior Walls
Installed to the exterior walls of the
garage including the fire wall
R-1 1
Kraft faced fiberglass batt
Interior walls
Wrap bedrooms, bathrooms, and laundry
room for sound
R-19
Unfaced fiberglass batt
Mid -floor
Install to the mid -floor
Air Infiltration
Ventilation Baffle
(Cardboard)
Ceiling Area Flat
Cardboard baffles installed into every
truss bay at eaves for attic ventilation.
Air infiltration
Poly vent baffles
Ceiling area sloped
Install to slope of upper level ceiling and
breakfast nook for air flow.
Air Infiltration
4 mil Poly
Exterior Walls
Install to the exterior walls as a vapor
barrier
Air Infiltration
6 mil Poly
Ceiling Area Flat
Install to the ceiling area as a vapor
barrier. (poly and blow)
Air infiltration
6 mil black poly
Crawl space floor
Sealed to the foundation with all seams
lapped and sealed
Air Infiltration
Fire Foam
Penetrations Per Code
Fire rated foam installed into electrical
& plumbing penetrations per code.
Includes low expanding foam to all
windows & doors, and white caulking
installed to the bottom of windows only
when needed.
R-21
Unfaced Fiberglass Batt
Rim Joist and Box Sills
R- 21 unfaced installed into the rims &
box sills.
R-11
Unfaced Fiberglass Batt
Crawl Space Walls
installed to the exterior stemwall &
mechanically fastened in place.
Job Address:104 Creek side
Rifle Co, 81650
__X/4/Zo
Page 1 of 2