HomeMy WebLinkAboutSoils Report 11.29.2006tech IIEiPWo17IH-PAWLAK GEOTECHNICAL November 29, 2006 Must: Architects Attn: Dan Muse 46 Weant Boulevard Carbondale, Colorado 81623 50-0C..ttm 11.cn11;4 Cll�nsn+.tSpihuti,t.1i.y:.1, 11 I 1 .irrc: V7C0V15•i9:i:i 15n. 91044S -:H 54 �nutsl;1tivoAtin•to.1cc11.cs� Job No.106 0943 Subject: Subsoil Study for Foundation Design and Percolation 'Test, Proposed I lewitt Guest House and Detached Garage, Lot 7. Roaring Fork Preserve, Garfield County, Colorado. Dear Mr. Muse: As requested, 1•iepwortlt-Pawlak Geoteclhnicul, lac, performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was Conducted in accordance with our agreement far geotechnical engineering services to Muse Architects dated November 1, 2006. The data obtained and our recommendations based an the pmposcd construction and subsurface conditions encountered are presented in ibis report. llepworih-Pawlak Geotechnical, inc. previously conducted a preliminary gem -clinical study for the development and presentee] aur findings in a report dated November 30, 2000, Job No. 100 627. Proposed Construction: The proposed guest house and detached garage will be single story wood frame stmentres located on the site as shown on Figure 1. Ground floors will be structural over a crawlspace for the guest pause and stub-on•gradc in the garage. Cut depths Are expected to be about 3 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction The septic disposal system is proposed to be located southwest of the structures. if building conditions or foundation loadings arc significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Condllione The site was vacant at the time of our field exploration. There are shallow irrigation ditches across the site. Two deeper irrigation ditches are located to the north of the guest house. The ground surface is relatively flat with a gentle slope down to the northwest. Vegetation consists of grass and weals with cottonwood irces olnng the larger ditches. Tim area of standing water shown on the site plan was not observed at the time of our site visit an November 20, 2006. Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating two exploratory pits in the building area and one profile pit in the septic disposal arra at the approximate locations sltovn► on Figure 1. The logs of the pias fire presented on Figure 2. Tlic subsoils encountered, below abaut 1 to I'A feet of topsoil, Parker 303.841.7119 • Colorado Sennas 719.633.5562 • Silvcrthnme 970168 l 9b9 -2 - generally consist or relatively dense, slightly silty sandy gravel with cobbles and small boulders. About 1 h feet of medium dense, silty to very silty sand was encountered between the topsoil area gravels in Pit 2. Po:sults or swell -consolidation testing performed on a relatively undisturbed -tempts of the silt and sand soils, presented on Figure 3, indicate low compressibility under existing moisture conditions and light loading and a low to nwderatc collapse potential (settlement under constant load) when wetted. The sample showed high comprossibility upon increased knitting after wetting. RcsuI1S of a gradation analysis performed on a sample of the gravels (minus 5 inch fraction) obtained from the site arc presented on Figure 4. The laboratory test results ore summarized in Table 1. No free water was observed in the pits at the time of excavation and the soils ware slightly moist to moist. A pit excavated on Lot 7 as part of the preliminary study encountered similar soils to cite excavated depth of 6 fent and groundwater at a depth of 5V2 feet in August 2000. Fouadatlan Bearing Conditions: Constructs on of the guest house and garage at the site should be feasible based on gentecttnical considerations. The natural gravel alluvium sail possesses moderate bearing capacity with a low risk of settlement and should be adequate for support of the proposed building foundation. Groundwater was observed in n pit excavated on lot as pari of the preliminary study at a depth of S`'h feet below the existing ground surface- It has been our experience in the arca that groundwater levels can rise during periods of seasonal runoff and heavy precipitation. Cue to the relatively shallow groundwater conditions encountered in the arca, crawlspacc arras should be relatively shallow and kept well ventilated. As an alternative, a slab -on -grade floor could be considered to reduce the risk of having a wet crawlspacc. Foundation Recommenrlatiosun Considering the subsoil conditions encountered in the exploratory pits and the mature of the prcnoscd construction, we recommend spread footings placed on the undisturbed natural gravel soil designed for an allowable soil caring pressure of 33 OO f for support of the proposrc�gucsl house an rEl ge. -The upper silt and sated soils tend to compress after wetting and there could be some post- construction foundation settlement. Footings should be a minimum width uf i 6 inches for continuous walls and 2 feet for co(uxrtns. Silty sand and loose disturbed soils cncauntc cJ ut the i'aundution fxas rig eve within the excavation should be removed and the footing tearing level extended down to the undisturbed natural gravel soils. Voids created by the removal of large rocks should be backfilled with compacted sand and gravel or with concrete. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. placement of footings at least 36 inches below the exterior grade is typically used in this arca. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least ID feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weights of at least 45 pef for the on-site soil, excluding vegetation, topsoil or oversized rock, as backfill. lob No.It)b owl -3 - door Stabs: The natural on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which of ow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking The requirements for joint spacing and slab reinforcement should be established by the designer based an experience and die intended slab use. A layer of -1/4-inch screen rock could be placed below slabs -on -grade as a leveling course. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density ata moisture content near optimum, Required fill can consist of the on-site gravel soils devoid of vegetation, topsoil and oversized rock. Surface Drainage: The following drainage precautions should be observed during construction and maintained nt all times idler the buildings have been completed 1) Inundation of the foundation excavations and understab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 6 inches in the first 10 feet in unpaved areas and a minimum slope of 3 im.bes in the first 10 feet in pavement and walkway omas. 4) Roof downspouts and drains should discharge well beyond the limits of all bacltft11. Percolation Testing: Percolation tests were conducted on November 21.2006 to evaluate the fcnsibility of an infihrinion at septic r ti locations shown l system at Figuretasite The test fide it and three percolation holes were dug (nominal 12 inch diameter by 12 inch deep) were hand dug et the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pit drown on Figure 2 and consist of about 11/2 feet of topsoil overlying slightly silty sandy gravel with cobbles and small boulders to the pit depth of 8 feet. The percolation test results are presented in Table 2. The percolation test results indicate infiltration rates between 3 and 5 minutes per inch with an average of4 minutes per inch. Based on the subsurface conditions encountered and the percolation test results, we recommend that a professional engineer be engaged to design the infiltration septic disposal system. Limitations: This study has been conducted in accordance with generally accepted gcuteclmical engineering principles and practices in this arca at this time. We make no wamutty either expressed or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Figure 1. the proposed type oI conSlrttCtion and our experience in Job No.106 0943 G+ " -4 - the arca. Our services do not include determining the presence, prevention or possibility ❑fmold or other biological contaminants (MOI3C) developing in the future. if the client is concerned about MODC, then a professional in this special field of practice should be consulted. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits mrd variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during curistructIan appear different fmtn those described in this report, we should be notilcd al once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We or not responsible for technical interpretations by others of our information. M the project evoive.s, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendntians have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by n representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Respectfully Submitted, HEPWORTh - PAWLAK G_ .`��, t j :'' ; NC. Reviewed by: Daniel E. Hardin, P.E. JZ.Nksw atlnehMeniS 1Figute 1 Figure 2 Figure 3 Figure 4 Table l - Tablc 2 - Location of Exploratory lits and 1'ercoluttvn fest I toles Logs of Exploratory Pits - Swell -Consolidation Test Results Gradation Test Results Summary of Laboratory Test Results Percolation Test Results cc: Ernest Kollar Engineers, Inc. - Attn: Ernie Kollar Joh 14o.1O6494 106 0943 Gig:Reel f LOCATION OF EXPLORATORY PRS AND PERCOLATION TEST HOLES ilavpgnrrMlt.rrt C1 FIGURE 1 PO t EL.EV.w 998' —5 PIT 2 ELEV s 909' WC'52 0093 2Mr50 PROFILE P17 ELEV 1001' — 10 LEGEND: TOPSOIL: sand! sot and day, arui roots, f m. moist, dark brown. ElSAND ISM); silty to very silly, medium dense. slightly moist. Yght brawn. i 44.411 J 200,2 5- 10 I3RAVELMD COBBLES (GP -GM): sandy, slightly silty, with small bauldere. dense. moist. Ohl brawn, subnxrnded to rounded rocks. 2' Diameter hand drum finer sample. _ Disturbed UUL sample. a NOTES: 1. Exploratory pits were excavated on November 20. 2006 with a Yanrnar kom was drawn on rhe site plan 2. Locations of meplora2o Y pts were measured eppreowrntaly by pacing pro aide 5. Elevations d exploratory pits were obtained by interpolation between contours shown an the site plan provided. Logs are drawn lo depth. 4. The ex ploraloly pit locations and elevations should be cnnsklefa d accurate only to the degree impieed by the method used 5. The lire between eletf fWs shwa e]n Ute explareiery pit logs represent the approximate brafrrdnries between - malarial types and eansibans may be gradual. O. No tee water was encountered in Ora pts at the time of excavating. Fluctuation in Wier levet may occ rwilh lime. T. Laboratory Tasting Reed WC 01 Water Content (% DO I- tory Density +4 - Percent xotainnd cn the No. 4 gave -200 M. t'eiC.enl passing No. 200 sieve 1060943 1---GettSWL. n. LOGS OF EXPLORATORY PITS 1 immure 2 ac 2 4 5 6 T 8 11 10 Moisture Content -1 5.2 Dry Renally In. 93 Sample 01: MI and Sand Front Pi1 2 at 2ji Feat GoolPress ur1 14P01'1 welling l { 1.0 APPUED PRESSURE -Id 10 i T 1 1 100 106 0943 I �"; IrrlMdl.+li w,wcao,,.cvil SWELL -CONSOLIDATION ZEST RESULTS Figure 3 i6 0. 10 I 1ira� s [ Wit AL 1 ill %NC U 51AF1 W1 SF3i[':s 1 GttN MARE as 41111 IMM -007.7 0/7014177} MIN l F11ri •l I r�3 111 a Ia 373" 31F 11!Z 3' 6's B' left INN_ 30 MES-11.1-rianigilliiV2 mumpririmmiliimarin aratiandilAringWElgallki 10E1 Dom 11 II I is OD 00 70 IID 0 .0 E - - errs 276 a.76 y$ 199 5r- 7112 1152 2172 .001 .007 g5 .077 1l9 1737 Z74 ,750 .263 OSMETEFI OF PAROCLEs 04 MILIJACIU07Gamma ,1:3=21=12=L mrn 12,8 GRAVEL 76 % UODUD LIMIT % SAMPLE OF' Sandy Gravel wilts Cobbles SAND 22 % SILT AND CLAY 2 % PLASTLCfY INDEX % FROM: PLl 3 at d Feet GRADATION TEST RESULTS 20 10 0 iFigur° HEPWORTH-PAWLAK GEOTECHNICAL., INC. TABLE 1 SUMMARY OF LABORATORY TEST RESULTS 300 No. 105 0943 S.MPLE LOCAflNATURAE. NATURAL ` . ON maga MCIS9URE CRY GRAVEL SAND1N 5 C PIT CUMCOMMIT 4B15i11r CV(%) LIMIT INCE( STM 1 l%1 PS R % I Silt and Sand 1 1 21 I 5.2 93 1.1111MEMMIIII Profile 3 to 4 M 11.1111MMEMili°11111111111.111111 IM MIIIIIMIIIIIIIIIIIIII MIIIIININIMMINIIIIMMINIIII 1111•Mimumil......M.1.11.11.....iiiiiimilimm111111MIMIA UNCONFINED COMPRESSIVE sori OR NORCO:TYPE Sandy Gravel with Cobbles