HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT-6509
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 9/30/2020 Expiration Date 9/30/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address TBD Fisher Creek Lane (Lot 8)
Owner Name Harry & Kathryn Peisach
Designed By CBO, Inc.
Contractor WRW Log Works
Parcel No. 239301401008
Owner Phone 970-920-7554
Designer Phone 970-309-5259
Contractor Phone 970-274-8412
Number of Bedrooms 4 Minimum Tank Capacity 1500-gallon Minimum Absorption 588 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated January 8, 2020. Changes to the design and permit must be approved
by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new four -bedroom residence. The system will consist of a new, two -
compartment precast concrete 1,550-gallon septic tank set level with access to grade and a pump in
the second compartment. A control panel for the pump will be placed within sight of the pump.
Effluent will be pumped to an automatic distributing valve set level with access to grade distributing
effluent to 600 ft2 of STA. The STA will consist of five trenches, each with 10 `Quick 4' chambers for a
total of 50 chambers. Inspection ports are to be installed at the beginning and end of each trench.
Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
AA, (0d —
cil301(90
Issued By: arfield County Environmental Health
Department
Date