HomeMy WebLinkAboutPermitPublic Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT-6505
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 10/15/2020 Expiration Date 10/15/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 30239 Highway 6 & 24, Rifle, CO 81650 Parcel No.: 2179-072-00-637
Owner Name: Jeff and Cody Nelson Owner Phone: (970) 319-4845
Designed By: Carla Ostberg Designer Phone: (970) 309-5259
Number of Bedrooms: 2 Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 960 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the application and design
documents as submitted by CBO, Inc. dated September 7, 2020. Changes must be approved by
Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a two -bedroom residence and domestic wastewater from future
commercial use. The system will consist of a 1,500-gallon, two -compartment septic tank set level
with access to grade with a high -head pump in the second compartment followed by an automatic
distribution valve to distribute effluent to 960 ftzof Soil Treatment Area (STA). The STA will consist of
five trenches of 16 Infiltrator Quick 4 chambers per trench for a total of 80 chambers. Effluent lines
from the pump to the ADV and from the ADV through the trenches will consist of 1.5-inch PVC.
Orifice sizing and spacing will be 5/32-inch and 3 feet on -center, respectively. Inspection ports are to
be installed at each end of the trenches. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
/."
10 15 2020
4�
Issued By: Garfield County Environmental Health
Department
Date