HomeMy WebLinkAboutEngineer's Letter 07.09.2020HERITAGE BUILDING SYSTEMS:, Established 1979 A Cornerstone Building Brands Company July 09, 2020 TRIDENT STEEL 3002 NORTH 1-70 FRONTAGE ROAD GRAND JUNCTION, CO 81504 17-B-69333 TRIDENT STEEL 160 GEMAT CIRCLE RIFLE,CO 81650 US 60'-0" x 80'-0" x 16'-0" To Whom It May Concern: This is to certify that materials for the subject structure have been designed in accordance with the order documents, specifically as shown per the attached Engineering Design Criteria Sheet. Aspects of code compliance as related to use or occupancy, such as sprinkler requirements, are not addressed by these documents. These materials, when properly erected on an adequate foundation in accordance with the erection drawings as supplied and using the components as furnished, will meet the attached loading requirements. This certification does not cover field modifications or the design of materials not furnished by Heritage Building Systems. The attached design criteria information is to remain with and form part of this Letter of Certification. The calculations and the metal building they represent are the product of Heritage Building Systems or a division of its affiliate Cornerstone Building Brands. The engineer whose seal appears hereon is employed by either Heritage Building Systems or a division of its affiliate Cornerstone Building Brands and is not the engineer of record for this project. Cordially, Heritage Building Systems Materials for Metal Buildings A Cornerstone Building Brands Company Ke Hu, P.E. Design Engineer This document has been digitally signed. 17-B-69333 Page 1 of 2 HERITAGE BUILDING SYSTEMS: Established 1979 A Cornerstone Building Brands Company Building Code IBC 15 Risk Category II - Normal Roof Dead Load Superimposed 2 150 psf Collateral 1 000 psf (Total) (0.00 psf Ceiling, 1 psf Other) Roof Live Load 20.00 psf Yes reduction Snow Ground Snow Load (Pg) 57.00 psf Snow Load Importance Factor (Is) 1.00 Snow Exposure Factor (Ce) 1.00 Thermal Factor (Ct) 1.00 Flat Roof Snow Load (Pf) 40.00 psf Minimum Roof Snow Load (Pm) 40.00 psf Wind Ultimate Wind Speed (Vult) 115 mph Nominal Wind Speed (Vasd) 89 mph (IBC Section 1609.3.1) Serviceability Wind Speed 76 mph Wind Exposure Category C Internal Pressure Coef (GCpi) 0.18/-0.18 Loads for components not provided by building manufacturer Wall Edge Zones 30.48 psf pressure -40.73 psf suction Other Wall Zones 30.48 psf pressure -33.06 psf suction These values are the maximum values required based on a 10 sq ft area. Components with larger areas may have lower wind loads. Seismic Seismic Importance Factor (Ie) 1.00 Seismic Design Category B Soil Site Class D Ss 0.303 g Sds 0.315 g S1 0.079 g Shc 0.126 g Analysis Procedure Equivalent Lateral Force Location...Int RF Front SW Back SW Left EW Right EW System H H H H H R 3 3 3 3 3 Cs 0.105 0.105 0.105 0.105 0.105 Design Base Shear in kips (V) Transverse 7.44 Longitudinal 7.40 Basic Structural System (from ASCE 7-10 Table 12.2-1) System - Basic Force Resisting System H - Steel System not Specifically Detailed for Seismic Resistance R - Response Modification Coefficient Cs - Seismic Response Coefficient 17-B-69333 Page 2 of 2