Loading...
HomeMy WebLinkAboutAs-built Report 10.12.20205020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado October 12, 2020 Mike Ruiz 775 Fir Avenue Rifle, Colorado 81650 (mike.unicorp@gmail.com) Project No. 17-7-798.02 Subject: Certification of Onsite Wastewater Treatment System, Proposed Residence, Lot 7, Native Springs, 19 Native Springs Drive, Garfield County, Colorado Dear Mike: A representative of Kumar & Associates observed the installation of the Onsite Wastewater Treatment System (OWTS) for the residence at the subject site as required by the Garfield County Environmental Health Department. Our observations and recommendations are presented in this report. The services are supplemental to Kumar & Associates agreement for professional services to you dated October 24, 2017. We previously designed the OWTS for the residence as submitted in our report dated September 17, 2020, Project No. 17-7-798.02. The system was designed for three bedrooms. We performed our evaluation on September 28, 2020. The OWTS components observed included: sewer line, cleanout, septic tank, effluent line, distribution box and soil treatment area (STA) and the locations of these components. The installation and locations of the system components were verified as shown on Figure 1. Pictures of the OWTS components made during the site visit are included with this report. The distance locations to the septic tank shown on Figure 1 were made by taping. The designed Tuf-tite 6-hole distribution box was changed to a precast concrete 8-hole distribution box. The designed Infiltrator Quick4 Plus Standard chambers (75 total chambers) were changed to Arc36 chambers and the size of the field adjusted to be similar to the design (60 chambers total). These changes are acceptable to us. It is our opinion that the OWTS was installed in general conformance with the above referenced design. The observations and recommendations presented above are based on our site observations and our experience in the area. We make no warranty either express or implied. Alterations to the system or improper backfill and site grading could affect the operation and effectiveness of the OWTS. Mike Ruiz October 12, 2020 Page 2 Please feel free to contact us if you have any questions regarding this letter. Sincerely, Kumar & Associates, Inc. `7K, -;_/1 400,e/Z, Shane M. Mello, Staff Engineer Reviewed by: David A. Young, P.E. SMM/kac attachments: Figure 1 - OWTS Photo cc: Jim Gornick (jgornick1988(a�gmail.com) Kumar & Associates, Inc. Project No. 17-7-798.02 PER SPIT PROF LE PIT 1 NORWESCO 1,000 GALLON TWO CHAMBER LOW PROFILE SEPTIC TANK PERC PIT 3 ROFILE / C-)1 PIT 2 . CONCRETE 8-HOLE DISTRIBUTION BOX SOIL TREATMENT AREA (STA) CONSISTING OF 5 TRENCHES WITH 12 ARC36 CHAMBERS IN EACH TRENCH. 60 CHAMBERS TOTAL. 17-7-798.02 Kumar & Associates E : RI►GS / 3 DROOM SIDENCE FF=5394.75' RECORD DRAWING Fig. 1 OWTS PHOTOGRAPH LOG PROPOSED RESIDENCE LOT 7, NATIVE SPRINGS 19 NATIVE SPRINGS DRIVE GARFIELD COUNTY, COLORADO Photograph 1: Cleanout and sewer line exiting residence. Photograph 2: Norwesco 1,000 gallon, two -chamber septic tank. Project No. 17-7-798.02 OWTS PHOTOGRAPH LOG PROPOSED RESIDENCE LOT 7, NATIVE SPRINGS 19 NATIVE SPRINGS DRIVE GARFIELD COUNTY, COLORADO Photograph 3: Inlet tee in septic tank. Photograph 4: Outlet tee and effluent filter. Project No. 17-7-798.02 OWTS PHOTOGRAPH LOG PROPOSED RESIDENCE LOT 7, NATIVE SPRINGS 19 NATIVE SPRINGS DRIVE GARFIELD COUNTY, COLORADO Photograph 5: Effluent line exiting septic tank to distribution box and to soil treatment area (STA). Photograph 6: 8-hole concrete distribution box with levelers in outlet effluent lines. Project No. 17-7-798.02 OWTS PHOTOGRAPH LOG PROPOSED RESIDENCE LOT 7, NATIVE SPRINGS 19 NATIVE SPRINGS DRIVE GARFIELD COUNTY, COLORADO Photograph 7: Typical STA trench, partially backfilled, consisting of 12 Arc36 chambers. Photograph 8: Observation ports and STA. Project No. 17-7-798.02