SUBSOIL STUDY
FOR FOUNDATION DESIGN
PROPOSED RESIDENCE
LOT 42, FILING 3, IRONBRIDGE
BLUE HERON DRIVE
GARFIELD COUNTY, COLORADO
PROJECT NO. 20-7-663
DECEMBER 4, 2020
PREPARED FOR:
E & L REAL ESTATE DEVELOPMENT, LLC
ATTN: LEO CARMICHAEL
0766 RIVER BEND WAY
GLENWOOD SPRINGS, COLORADO 81601
(1c945@outlook.com)
TABLE OF CONTENTS
PURPOSE AND SCOPE OF STUDY - 1 -
PROPOSED CONSTRUCTION - 1 -
SITE CONDITIONS - 1 -
GEOLOGY -2-
FIELD EXPLORATION - 2 -
SUBSURFACE CONDITIONS - 3 -
FOUNDATION BEARING CONDITIONS - 3 -
DESIGN RECOMMENDATIONS - 4 -
FOUNDATIONS - 4 -
FLOOR SLABS - 5 -
UNDERDRAIN SYSTEM - 5 -
SURFACE DRAINAGE - 6 -
LIMITATIONS - 6 -
FIGURE 1 - LOCATION OF EXPLORATORY BORINGS
FIGURE 2 - LOGS OF EXPLORATORY BORINGS
FIGURE 3 - LEGEND AND NOTES
FIGURE 4 - SWELL -CONSOLIDATION TEST RESULTS
TABLE 1- SUMMARY OF LABORATORY TEST RESULTS
Kumar & Associates, Inc. ° Project No. 20-7-663
PURPOSE AND SCOPE OF STUDY
This report presents the results of a subsoil study for a proposed residence to be located on
Lot 42, Filing 3, Ironbridge, Blue Heron Drive, Garfield County, Colorado. The project site is
shown on Figure 1. The purpose of the study was to develop recommendations for the
foundation design. The study was conducted in accordance with our agreement for geotechnical
engineering services to Red Dear Realty dated October 30, 2020.
Exploratory borings were drilled to obtain information on the subsurface conditions. Samples of
the subsoils obtained during the field exploration were tested in the laboratory to determine their
classification, compressibility or swell and other engineering characteristics. The results of the
field exploration and laboratory testing were analyzed to develop recommendations for
foundation types, depths and allowable pressures for the proposed building foundation. This
report summarizes the data obtained during this study and presents our conclusions, design
recommendations and other geotechnical engineering considerations based on the proposed
construction and the subsurface conditions encountered.
PROPOSED CONSTRUCTION
Development plans were preliminary at the time of our study. In general, the proposed residence
will be single -story, 2,000 square feet in size with an attached 3 car garage. Ground floors will
be structural over crawlspace in the living area with a slab -on -grade garage floor. Grading for
the structure will be relatively minor with cut depths between about 2 to 3 feet. We assume
relatively light foundation loadings, typical of the proposed type of construction.
If building loadings, location or grading plans change significantly from those described above,
we should be notified to re-evaluate the recommendations contained in this report.
SITE CONDITIONS
The site was vacant at the time of our field exploration. The lot slopes gently down to the north
across the building area then drops moderately down about 5 feet to gently sloping, relatively
natural terrain. Vegetation consists of sparse weeds. The downhill side of Blue Heron Drive
Kumar & Associates, Inc. ° Project No. 20-7-663
-2 -
appears to be a fill bench for residence construction placed during the subdivision development.
The Roaring Fork River is located downhill about 1/4 mile to the north.
GEOLOGY
The geologic conditions were described in a previous report conducted for planning and
preliminary design of the overall subdivision development by Hepworth-Pawlak Geotechnical
(now Kumar & Associates) dated October 29, 1997, Job No. 197 327. The natural soils on the
lot mainly consist of sandy silt and clay alluvial fan deposits overlying gravel terrace alluvium of
the Roaring Fork River. The river alluvium is mainly a clast-supported deposit of rounded
gravel, cobbles and boulders typically up to about 2 to 3 feet in size in a silty sand matrix and
overlies siltstone/claystone bedrock.
Bedrock of the Pennsylvanian age Eagle Valley Evaporite underlies the Ironbridge subdivision.
These rocks are a sequence of gypsiferous shale, fine-grained sandstone and siltstone with some
massive beds of gypsum and limestone. Dissolution of the gypsum under certain conditions can
cause sinkholes to develop and can produce areas of localized subsidence. A sinkhole occurred
in the parking lot adjoining the golf cart storage tent in January, 2005 located about '/4 mile to the
southeast of Lot 42 which was backfilled and compaction grouted. To our knowledge, that
sinkhole has not shown signs of reactivation such as ground subsidence since the remediation.
Sinkholes possibly related to the Evaporite were not observed in the immediate area of the
subject lot. Based on our present knowledge of the subsurface conditions at the site, it cannot be
said for certain that sinkholes related to the underlying Evaporite will not develop. The risk of
future ground subsidence on Lot 42 throughout the service life of the proposed building, in our
opinion, is low; however, the owner should be made aware of the potential for sinkhole
development. If further investigation of possible cavities in the bedrock below the site is desired,
we should be contacted.
FIELD EXPLORATION
The field exploration for the project was conducted on November 10, 2020. Two exploratory
borings were drilled at the locations shown on Figure 1 to evaluate the subsurface conditions.
The borings were advanced with 4 -inch diameter continuous flight augers powered by a truck -
Kumar & Associates, Inc. ° Project No. 20-7-663
-3 -
mounted CME -45B drill rig. The borings were logged by a representative of Kumar &
Associates.
Samples of the subsoils were taken with 1% inch and 2 -inch I.D. spoon samplers. The samplers
were driven into the subsoils at various depths with blows from a 140 pound hammer falling 30
inches. This test is similar to the standard penetration test described by ASTM Method D-1586.
The penetration resistance values are an indication of the relative density or consistency of the
subsoils. Depths at which the samples were taken and the penetration resistance values are
shown on the Logs of Exploratory Borings, Figure 2. The samples were returned to our
laboratory for review by the project engineer and testing.
SUBSURFACE CONDITIONS
Graphic logs of the subsurface conditions encountered at the site are shown on Figure 2. The
subsoils consist of about 6 feet of relatively dense, mixed clay, silt, sand and gravel fill overlying
about 5 to 10 feet of stiff, sandy silty and clay. Dense, slightly silty sandy gravel with cobbles
was encountered below the silt and clay soils at depths of 10'/2 to 16 feet down to the bottom of
the borings of 15 to 21 feet. Drilling in the dense granular soils with auger equipment was
difficult due to the cobbles and possible boulders.
Laboratory testing performed on samples obtained from the borings included natural moisture
content and density and finer than sand size gradation analyses. Results of swell -consolidation
testing performed on a relatively undisturbed drive sample of the silt and clay soils, presented on
Figure 4, indicate low compressibility under light loading and a minor expansion potential when
wetted under light loading. The laboratory test results are summarized in Table 1.
No free water was encountered in the borings at the time of drilling the subsoils were slightly
moist.
FOUNDATION BEARING CONDITIONS
Spread footing foundations placed on the relatively dense fill soil above the natural silt and clay
soils should be adequate for support of the proposed residence. Although the silt and clay soil
sample showed a minor expansion potential when tested, our experience in this area is that
Kumar & Associates, Inc. ° Project No. 20-7-663
-4 -
expansion shown in the test is not indicative of the typical behavior of the silt and clay soils in
this area. The bearing condition of the soils exposed in the excavation should be further
evaluated at the time of construction.
DESIGN RECOMMENDATIONS
FOUNDATIONS
Considering the subsurface conditions encountered in the exploratory borings and the nature of
the proposed construction, we recommend the building be founded with spread footings bearing
on the relatively dense fill soils above the natural silt and clay soils.
The design and construction criteria presented below should be observed for a spread footing
foundation system.
1) Footings placed on the relatively dense fill soils should be designed for an
allowable bearing pressure of 1,500 psf. Based on experience, we expect initial
settlement of footings designed and constructed as discussed in this section will
be about 1 inch or less. Post -construction settlement could be around 1/2 to 1 inch
mainly if the bearing soils are wetted.
2) The footings should have a minimum width of 18 inches for continuous walls and
2 feet for isolated pads.
3) Exterior footings and footings beneath unheated areas should be provided with
adequate soil cover above their bearing elevation for frost protection. Placement
of foundations at least 36 inches below exterior grade is typically used in this
area.
4) Continuous foundation walls should be heavily reinforced top and bottom to span
local anomalies such as by assuming an unsupported length of at least 12 feet.
Foundation walls acting as retaining structures should also be designed to resist a
lateral earth pressure corresponding to an equivalent fluid unit weight of at least
55 pcf for the onsite soils as backfill.
5) Any topsoil and loose disturbed soils should be removed and the footing bearing
level extended down to the relatively dense fill soils. The exposed soils in footing
area should then be moistened and compacted. Additional structural fill can
Kumar & Associates, Inc. ° Project No. 20-7-663
-5 -
consist of the onsite soils compacted to at least 98% of standard Proctor density at
near optimum moisture content. New structural fill should extend laterally
beyond the footing edges a distance equal to at least one-half the fill depth below
the footing.
6) A representative of the geotechnical engineer should observe all footing
excavations prior to concrete placement to evaluate bearing conditions.
FLOOR SLABS
The on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade
construction. To reduce the effects of some differential movement, floor slabs should be
separated from all bearing walls and columns with expansion joints which allow unrestrained
vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage
cracking. The requirements for joint spacing and slab reinforcement should be established by the
designer based on experience and the intended slab use. A minimum 4 -inch layer of road base
gravel should be placed beneath garage level slabs. This material should consist of minus 2 -inch
aggregate with at least 50% retained on the No. 4 sieve and less than 12% passing the No. 200
sieve.
All fill materials for support of floor slabs should be compacted to at least 95% of maximum
standard Proctor density at a moisture content near optimum. Required fill can consist of the
onsite soils devoid of vegetation, topsoil and oversized rock.
UNDERDRAIN SYSTEM
The proposed shallow (less than 4 feet) crawlspace and slab -on -grade garage should not require a
perimeter underdrain system provided that the site grading recommendations contained in this
report are followed. We recommend that below -grade construction, such as retaining walls, deep
crawlspace and basement areas, be protected from wetting and hydrostatic pressure buildup by
an underdrain system.
If installed, the drains should consist of drainpipe placed in the bottom of the wall backfill
surrounded above the invert level with free -draining granular material. The drain should be
placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and
Kumar & Associates, Inc. ° Project No. 20-7-663
-6 -
sloped at a minimum 1% to a suitable gravity outlet or drywell. Free -draining granular material
used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than
50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill
should be at least 11/2 feet deep. An impervious membrane such as 30 mil PVC should be placed
beneath the drain gravel in a trough shape and attached to the foundation wall with mastic to
prevent wetting of the bearing soils.
SURFACE DRAINAGE
Proper surface grading and drainage will be critical to prevent wetting of the bearing soils and
satisfactory performance of the foundation. The following drainage precautions should be
observed during construction and maintained at all times after the residence has been completed:
1) Inundation of the foundation excavations and underslab areas should be avoided
during construction.
2) Exterior backfill should be adjusted to near optimum moisture and compacted to
at least 95% of the maximum standard Proctor density in pavement and slab areas
and to at least 90% of the maximum standard Proctor density in landscape areas.
3) The ground surface surrounding the exterior of the building should be sloped to
drain away from the foundation in all directions. We recommend a minimum
slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of
3 inches in the first 10 feet in paved areas. Free -draining wall backfill (if any)
should be capped with about 2 feet of the on-site soils to reduce surface water
infiltration. Graded swales should have a minimum slope of 3%.
4) Roof downspouts and drains should discharge well beyond the limits of all
backfill.
5) Landscaping which requires regular heavy irrigation should be located at least
10 feet from foundation walls. Consideration should be given to use of xeriscape
to reduce the potential for wetting of soils below the building caused by irrigation.
LIMITATIONS
This study has been conducted in accordance with generally accepted geotechnical engineering
principles and practices in this area at this time. We make no warranty either express or implied.
Kumar & Associates, Inc. ° Project No. 20-7-663
-7 -
The conclusions and recommendations submitted in this report are based upon the data obtained
from the exploratory borings drilled at the locations indicated on Figure 1, the proposed type of
construction and our experience in the area. Our services do not include determining the
presence, prevention or possibility of mold or other biological contaminants (MOBC) developing
in the future. If the client is concerned about MOBC, then a professional in this special field of
practice should be consulted. Our findings include interpolation and extrapolation of the
subsurface conditions identified at the exploratory borings and variations in the subsurface
conditions may not become evident until excavation is performed. If conditions encountered
during construction appear different from those described in this report, we should be notified so
that re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes. We are not
responsible for technical interpretations by others of our information. As the project evolves, we
should provide continued consultation and field services during construction to review and
monitor the implementation of our recommendations, and to verify that the recommendations
have been appropriately interpreted. Significant design changes may require additional analysis
or modifications to the recommendations presented herein. We recommend on-site observation
of excavations and foundation bearing strata and testing of structural fill by a representative of
the geotechnical engineer.
Respectfully Submitted,
Kumar & Associates, Inc.
Steven L. Pawlak. P.
Reviewed by:
11,0
Daniel E. Hardin, P.E.
SLP/kac
Kumar & Associates, Inc.
Project No. 20-7-663
Blue Heron Drive\Drafting\20]
10 0 10 20
APPROXIMATE SCALE -FEET
20-7-663
Kumar & Associates
LOCATION OF EXPLORATORY BORINGS
Fig. 1
DEPTH -FEET
0
5
10
15
20
BORING 1
EL. 102'
•
•
♦I
•
•
36/12
39/12
WC=10.1
DD=122
-200=84
13/12
WC=1 1 .3
/ DD=100
/
26/12
1 54/12
BORING 2
EL. 100'
•
•
♦I
••
49/12
WC=5.0
DD=125
-200=46
17/12
29/6, 50/4
BORING 3
EL. 102'
•
•
•
•
•
/
/
//
0
5
10
15
20
25 25
DEPTH -FEET
20-7-663
Kumar & Associates
LOGS OF EXPLORATORY BORINGS
Fig. 2
—Blue Heron Drive\ Drafting\ 2076
LEGEND
11
I
FILL: MIXED SILT, CLAY, SAND, AND GRAVEL, MEDIUM DENSE TO DENSE, SLIGHTLY MOIST,
MIXED BROWN.
SILT AND CLAY (ML—CL); SANDY, STIFF, SLIGHTLY MOIST, BROWN.
SAND, GRAVEL AND COBBLES (GM—GP); SLIGHTLY SILTY, PROBABLE SMALL BOULDERS, DENSE,
SLIGHTLY MOIST, BROWN, ROUNDED ROCKS.
DRIVE SAMPLE, 2—INCH I.D. CALIFORNIA LINER SAMPLE.
DRIVE SAMPLE, 1 3/8—INCH I.D. SPLIT SPOON STANDARD PENETRATION TEST.
36/12 DRIVE SAMPLE BLOW COUNT. INDICATES THAT 36 BLOWS OF A 140—POUND HAMMER
FALLING 30 INCHES WERE REQUIRED TO DRIVE THE SAMPLER 12 INCHES.
NOTES
1. THE EXPLORATORY BORINGS WERE DRILLED ON NOVEMBER 10, 2020 WITH A 4—INCH—DIAMETER
CONTINUOUS—FLIGHT POWER AUGER.
2. THE LOCATIONS OF THE EXPLORATORY BORINGS WERE MEASURED APPROXIMATELY BY PACING
FROM FEATURES SHOWN ON THE SITE PLAN PROVIDED.
3. THE ELEVATIONS OF THE EXPLORATORY BORINGS WERE OBTAINED BY INTERPOLATION BETWEEN
CONTOURS ON THE SITE PLAN PROVIDED.
4. THE EXPLORATORY BORING LOCATIONS AND ELEVATIONS SHOULD BE CONSIDERED ACCURATE
ONLY TO THE DEGREE IMPLIED BY THE METHOD USED.
5. THE LINES BETWEEN MATERIALS SHOWN ON THE EXPLORATORY BORING LOGS REPRESENT THE
APPROXIMATE BOUNDARIES BETWEEN MATERIAL TYPES AND THE TRANSITIONS MAY BE GRADUAL.
6. GROUNDWATER WAS NOT ENCOUNTERED IN THE BORINGS AT THE TIME OF DRILLING.
7. LABORATORY TEST RESULTS:
WC = WATER CONTENT (%) (ASTM D2216);
DD = DRY DENSITY (pcf) (ASTM D2216);
—200= PERCENTAGE PASSING NO. 200 SIEVE (ASTM D1140).
20-7-663
Kumar & Associates
LEGEND AND NOTES
Fig. 3
1
0
—1
N
—2
Z
O
—4
These test results apply only to the
samples tested. The testing report
shall not be reproduced, except in
full, without the written approval of
Kumar and Associates, Inc. Swell
Consolidation testing performed in
accordance with ASTM D-4546.
SAMPLE OF: Sandy Silt and Clay
FROM: Boring 1 CO 10'
WC = 11.3 %, DD = 100 pcf
EXPANSION UNDER CONSTANT
PRESSURE UPON WETTING
1.0 APPLIED PRESSURE — KSF
10
100
20-7-663
Kumar & Associates
SWELL—CONSOLIDATION TEST RESULTS
Fig. 4
K±A
Kumar & Associates, Inc. ®
Geotechnical and Materials Engineers
and Environmental Scientists
TABLE 1
SUMMARY OF LABORATORY TEST RESULTS
Project No. 20-7-663
SAMPLE LOCATION
NATURAL
MOISTURE
CONTENT
(%)
NATURAL
DRY
DENSITY
(pcf)
GRADATION
PERCENT
200 SIEVE PASSING NO.
ATTERBERG LIMITS
UNCONFINED
COMPRESSIVE
STRENGTH
(psf)
SOIL TYPE
BORING
DEPTH
(ft)
GRAVEL
o)
(/o
SAND
�o
(o)
LIQUID LIMIT
(%)
PLASTIC
INDEX
(%)
1
5
10.1
122
84
Sandy Silt and Clay (Fill)
10
11.3
100
Sandy Silt and Clay
2
21/2
5.0
125
46
Clayey Sand and Silt with
Gravel (Fill)