Loading...
HomeMy WebLinkAboutPermitGarfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT -6664 Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 02/18/2021 Expiration Date 02/18/2022 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 41 County Road 221 Rifle, CO 81650 Parcel No.: 217711200495 Owner Name: Felipe and Cristina Venzor Owner Phone: (970) 379-9155 Designer Phone: (970) 945-1004 Number of Bedrooms: 4 Minimum Tank Capacity: 1,250 -gallon Minimum Absorption: 1 838 ft2 Designed By: SGM, INC. Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by SGM, Inc. dated November 23, 2020. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new four-bedroom residence. The system will consist of a new, two- compartment 1,250 -gallon septic tank set level with access to grade with an effluent filter in the outlet tee of the tank. Effluent will gravity flow to a distribution box set level with access to grade distributing effluent to 1,838 ft2 of STA. The STA will consist of eight chamber trenches, each with 22 'Quick 4' Standard Infiltrator chambers for a total of 176 'Quick 4' chambers (2,112 ft2). Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 4S hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. ... ....,. ,;_, ...., ......„ --,_ . z ' firS r_ 02/18/2021 i Issued By: Garfield County Environmental Health Department Date