HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6664
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 02/18/2021 Expiration Date 02/18/2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 41 County Road 221 Rifle, CO 81650 Parcel No.: 217711200495
Owner Name: Felipe and Cristina Venzor Owner Phone: (970) 379-9155
Designer Phone: (970) 945-1004
Number of Bedrooms: 4 Minimum Tank Capacity: 1,250 -gallon Minimum Absorption: 1 838 ft2
Designed By: SGM, INC.
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by SGM, Inc. dated November 23, 2020. Changes to the design and permit must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new four-bedroom residence. The system will consist of a new, two-
compartment 1,250 -gallon septic tank set level with access to grade with an effluent filter in the
outlet tee of the tank. Effluent will gravity flow to a distribution box set level with access to grade
distributing effluent to 1,838 ft2 of STA. The STA will consist of eight chamber trenches, each with 22
'Quick 4' Standard Infiltrator chambers for a total of 176 'Quick 4' chambers (2,112 ft2). Inspection
ports are to be installed at each end of each trench. Maintain all setbacks and elevations as
designed.
Contact the designer and Garfield County Public Health at least 4S hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
...
....,. ,;_, ...., ......„
--,_ . z ' firS r_
02/18/2021
i
Issued By: Garfield County Environmental Health
Department
Date