HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
Permit Number SEPT-6691
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Type X New X Repair X Remodel/addition'X Tank only
Issue Date 03/01/2021 Expiration Date 03 01 2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: Lot 5, Wooden Deer Subd ivision 81623 Parcel No.: 239324304005
Owner Name: Jason and Jamie Olden Owner Phone: (303) 817-9080
Designed By: High Country Engineering, Inc. Designer Phone: (970) 945-8676
Contractor: Crawford Design Build LLC. Contractor Phone: (970) 309-9151
Number of Bedrooms: 4 Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 656.3 ftZ
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by High Country Engineering, Inc. dated February 4, 2021. Changes to the design and
permit must be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new four -bedroom residence. The system will consist of a new, two -
compartment 1,250-gallon septic tank set level with access to grade with an effluent filter in the
outlet tee of the tank, followed by a 500-gallon single -compartment pump tank with a 52.5 GPD
minimum pump. Effluent will be pumped to an automatic distributing valve set at the high point of
the system that will distribute effluent to 675 ft2 of STA. The STA will consist of three chamber
trenches placed on three -feet of secondary sand media with 1/8-inch orifices 4-feet on center.
Distribution laterals are to be 1 % inch Schedule 40 PVC, with the laterals ending in flushing valves at
the distal end of the laterals. Inspection ports are to be installed at both ends of each trench.
Maintain all setbacks and elevations as designed.
Contact the designer and' Garfield County Public Health at Fast 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
�.
03/01/2021
Issued By: Garfield County Environmental Health
Department
Date