HomeMy WebLinkAboutAs-Built OWTS Plan 03.08.20211__�' Well 20 $-A GRAD ZI_ E C GraveI ` ,e},� is as Driveway ® s LAV cdbin 1 1 ( IN FEET ) 1 inch = 20 ft. r � • 2.0t f y Driveway Z Gravel Driveway so / �e $Lim / ' aiibOlX • y r f '" '` - _r /• ABSORPTION REATMENT FIELD PRESSURE DOSED CHAMBER TRENCHES z-.....• O-, INSTALLED 72 QUICK-4 CHAMBERS IN (4) 74' LENGTH TRENCHES WITH 1$ �z.. Wood1� sr.. f CHAMBERS PER TRENCH PLUS END CAPS FOR A TOTAL ABSORPTION"` IMIP -; R7 AREA OF 840 S.F. MAXIMUM AVERAGE TRENCH EXCAVATED DEPTH OF ;::; v>i _ ....: Y �aulder's Lo 30"INCHES BELOW EXISTING SURFACE GRADES WITH A MINIMUM EXISTING 12-INCHES OF COVER OVER THE CHAMBERS '-,...:.�..:. + ° CLEANOUTS j EXISTING = j 1 f 4-BEDROOM - ` 0 1.5" SCHD-40 DISTRIBUTION PiPES / t HOUSE I .5"PVC 5CI-1D-40 CUSTOM PERFORATED PIPE DISTRIBUTION LATERALS t a INSTALLED AT MIN. 2% TO END CAP LATERAL WITH 5/32-INCH DiA. ORIFICES EVERY 2.0-FEETALONG THE LATERAL PIPE & t .e : ! va Story `2. w PIPE CONNECTION FROM HP ADLI MP) PLACED ON THE TOP OF THE ABSORPTIVE SURFACE. WIRE STAPLES USED Home : �-+ TO SECURE PRESSURE PIPE TO SURFACE. ORIENTED ORIFICES BETWEEN THE 9 Q AUTOMATIC DISTRIBUTING VALVE FIRST& LAST TO SPRAY UPWARD (12 O'CLOCK} TOWARD TOP INTERIOR OF 4 PORT 1.5" {Vb404} ORENCO IN CHAMBERS, FIRST& LAST S/32" ORIFICES ORIENTED DOWNWARD WITH 6.7 1,3+ " l 30" DIA, 24" TALL RIBBED PVC SNAP ON SPRAYSHiELDS AT BOTH ENDS OF DISTRIBUTION LATERAL RISER W/ LID. INLET SET AT HP. t EXISTING 4" PVC GRAVITY SEWER PIPE 74' 4 r ;.:.: , : •' y ^• � � . ,. T.5"SCHD-40 TRANSPORT W/ 2.0' MIN. DEPTH OF BURY_ 4' INSTALL AT MIN. 2.596 FOR DRAWBACK ZTC f ' EXISTING ELECTRIC SERVICE PANEL Erc ere 24 f INSTALLED 4" RISER PIPE INSPECTION PORT AT 19.5EACH END CHAMISER W/CAP12"ABOVE \ INSTALLED UNDERGROUND ELECTRICAL WIRES IN \ SURFACE (TYP. ) INSTALLED 1.5" FLUSH BALL VALUE CONDUIT FROM HOUSE EXTERIOR ELECTRIC INSTALLED 2-COMPARTMENT I,000-GALLON REINFORCED PLASTIC ON END OF EACH DISTRIBUTION LATERAL BELOW SfRViC€ BOX TO POST MOUNT CONTROL PANEL SEPTIC DOSING TANK EACH INSPECTION PORT TYP. END EA. ROW) ) ' INSTALLED WiTH (2124" DIA. BY 30" DEEP RIBBED PVC RISERS W/ LID AT E L 2-COMPARTMENT X 1 ,0g0 GAL, COMPARTM NT �THE SURFACE. INSTALLED ORENCO BIOTUBE SIMPLEX EFFLUENT PUMP � CONCRETE SEPTIC TANK INSTALLED DICK-4 PLUS CHAMBER END CAP ASSEMBLY. PVU57-1819-L W P300511 PUMP W 1.5" DISCHARGE Q � l 1 I 1, I INSTALLED ORENCO PUMA CONTROL PANEL ASSEMBLY iN SECOND COMPARTMENT ON ALL END CHAMBERS ......... . 5X6 POST MOUNTED ELECTRICAL/CONTROL WIRES FROM POSTMOUNT CONTROL PANEL TO EXTERIOR SPICE BOX ON RISER. INSTALLED 14 GAUGE WIRES IN 1" CONDUIT 54{. 9' 1 lino what's below. II before you dig. CALL 2 LJSINESS DAYS IN ADVANCE BEFORE Y DIG, GRADE, OR EXCAVATE FOR7HEM KING ❑FLINDERGROLZI-0- 1000 Gallon Top Seam - 2CP Item ff with High Head Pump ZLLP-HH -tit' ...r. ... ''-'•-`�- +• .. TOP DESIGN NOTES • Design per performance test per ■►I �.� •�' ■Lew ,'�- ASTM C1227 , • Top turbot area 48.25 ft'� .� 4 • fa O 28 days: concrete = 8,000 PSI min. or CE: Inlnstallatlan; ` • Tank to be set on 5' min. sand bed or pea grove Ll J • Tonk to be backfllled unlfarmly on dII sides In lifts less than 24" and .•.-r. -+qr- Tti > ,,••s.T•. ; mechanically compacted - • Excavated material may be used for backfIll, provided large stones are W Illlrriniu 0 removed i IM HOW • Excovotlan should be dewatered and tank Tilled with water prior to being put ,r Service far inetollatmn with tbid dteon'•Led wafer table less than 2' below grade We - Meets C1644-06 for reslllent Connectors Dled - Inlet and Outlet idenflfied above pipe B00i ti • Delivered complete with lntarnal _ p1pin9 I11wobw • Control Panel to be mounted in eight Sti0 lne of tank • 4' Maximum bury depth 7 t or ALLOWABLE BURY - {Based on Water Table) WATER TAME111 _ . - - ..• _ �7v�uOl� • low VIGIN l'-a• S• -O" 2'-0" S•-0' 3' - a' 4' - a• • LOYr�1ST9SS>AdWlprlfllesiaDwk ORY +' - a•�� �x`i/VICY Ct1f16�Ctd 8NiSAdf9 itorrrle�nanca• � �"••�� plgging Specs Invst Dimensions Net Popoeity Net W"t Mtn, 11' Long x T' wlae nls! C1sUet Lenglh "to rioight Inl•! Side Wklat Total Lid I Tonk I Total 56' below In lei 56' 54"or73" 111" 60' 02" 687 gal 325 ga f010 got: 2e20 lbs 9380 be 2200 be Phone: 719395-6764 o VALLEY Fax: 719-395-37z7 PRECAST, inc. websrte: www.valleyprecastcom Buena Vlata, COlomdto Enull: Fran desk lwypracastaon't DOSING TANK PUMP ASSEMBLY DETAIL ALTERNATIVE: USE PLASTIC ROTH TANK N.T.S. Cayneron Wtkawr Book 1585 page 222 nfFTS DE'IS'ICEN PLAN PVC Enclosure in 30" Diameter only Stainless Steel Bolts and Urethane Gasket Transport Line Dosing Tan k euuu 5enee 1.5" Inlet & outlet 15 -100 gpm flowrate Height Varies 0E � m® Valve Assarnbly Discharge Laterals igure 4: 6000 SERIES AUTOMATIC DISTRIBUTION VALVE N.T.S. i L�lN. f 6" MIN. It 4" MIN. NATIVE, YARD OR LANDSCAPED SURFACE EXCAVATED MATERIAL COMPACTED TO 90% STANDARD PROCTOR CROWN FIELD TRENCH TO DIVERT SURFACE WATER REVEGATATION TOPSOIL LAYER BACKFILL LAYER NATIVE ONSiTE SOILS�mill -SUITABLE NATIVE BACKFILL FILTER FABRIC 4 COMPACTED SUBGRADE BACKFILL WITH SCREENED TRENCH CROSS-SECTION FOR ONSITE SOILS FREE OF ROCKS SDR-35 9R nP SCHD-An PIPES GENERAL NOTES: 1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERINq 1.5" SCHD-40 PERFORATED PVC 2• THE PROPOSED LOT CONDITIONS BYSOPRiS ENGINEERING AND OWNERS. DISTRIBUTION LATERAL PIPE W/ BALLVALVE @ CAP TERMINAL END 3. THE EXISITNG LOT CONDITIONS PER COUNTY GIS DATA BASE, AERIAL MAPPING, LIDAR TOPOGRAPHY AND SURVEY INFORMATION BY BOOK CLIFFS 5URVEY SERVICES, INC. 4. PRIMARY OWNER NAME & ADDRESS- CRAIG WILCOX 3' MIN 4' MIN 0188 COUNTY RD 226 S. RIFLE CO 8I650 6. LEGAL SUMMARY: A PARCEL IN SEC 9 & 11 T55 R92W 6TH PM, M/B 12" MIN.-24" MAX. 7. SITE ADDRES5: 0188 COUNTY RD 226, RIFLE, CO 81650 !! S. PARCEL NUMBER: 212709100018 LEACHING CHAMBER 9. GARFIEL❑ COUNTY PERMIT #:SEPT-6617, issued 1210212020 CONTRACTOR: KURTIS GEENMAN, KEG ENTERPRISES PREVIOL15 CURRENT 1505 PERMIT NUMBER 4419 155UED 10-09-08 PREVIOUS CONTRACTOR WALT€RS EXCAVATION 6" N.T.S. CONNECT 1,5 TRANSPORT PIPE FROM ADV �� �\ \� 3" CONCRETE IND TO INDIVIDUAL 1.5" PRESSURE DISTRIBUTION PiPE. TRANS PORT LEVELING COURSE NPE INVERT A MIN. 2" HiGHER THAN INVERT OF PRESSURE SCARIFY/TiLL BOTTOM SURFACE DI5TR1 BUTTON LATERAL CONNECTION. TO 3 ' DEPTH, PLACE 3 SAND & END PLATE INLET PORT RAKE LEVEL 1.5" SCHD-40 PVC PRESSURE DISTRIBUTION PIPE TO 1.5" LEACHING CHAMBER TRENCH (TYP.) UNDISTURBED EARTH CUSTOM PERFORATED DISTRIBUTION LATERAL PIPE CLAY LOAM CHAMBER TRENCH CROSS SECTION DETAIL fIr CHAMBER END CAP N.T.S. CHAMBER END CAP CONNECTION DETAIL N.T.S. 'P�1111■11111111111111111111111111111 '' ' '- 1111►IIIII►®11111111111111111111111 • r 11 � _ - IIIIil111111iI11111111111111111111I 1 - - - :" :' �' _ �I :� 11111111111111111111111111111111111 •• -,IIIIIIIIIIIIIIIIIiI1111111111111111 III111IIIIIII1111111111111III11111 IIII 1111111111111111111111111111111 r � ' ®II11 111 11111111IIIIIIIIIIIiIIIIII - II�i111II I11111 11I11111I 1111 1 1 _ �1 ��1111111111111111111I111111111 ' ' •®111111111111111111111�11111111 _ -�11 III I11 II�iIiIIIIIIIIIIIIIIa1111111 11 1111lI111111�l111111111111 III - i111111111111i11111iIIIl11I11111 111 III 111111111111i1II111f1111111►1111 i �1 I11 III IIIIII II I iIi IIIII►. III il� IIII�II I � - 11MI1 I111111111111111111I111►111111 1 III 111 III MINE III MINES 111�11111 IIIIIIIIIIIIIIIi111i111111I11I111►IIIII - 111111111111111111111IIIiIIiM111 111 11111111111111111111111111111111 '111 111111111111i1I1111i1111iI11111 ,111 ■ 1111111111111111111111111111��11� LIII IIIIIIIIIIIIi11I11111111111111i31INN 11 �11�s111111111I111®111lIIIIIIIIIIIIi� - - II111i11111111111111111111.Ii iii iii ii IIIII iii ii IIIII iw� _ IIM-902:0iiiiIIIIIIIIIIIIIIIIII _ �oil I ' EXISTING CONDITIONS S UR VE Y PREVIOUS SURVEY PLAT CRAPH'C SCALE PROPERTYaESC'ItIF7TON A PaRTIOM nr N'RLYS iPlF:.i FAfI.S RAC Nores r.J wrs w sr�xvar wAs rnxr_x s, a�oe 21 C WfrrWrr la7Pjj1L'AL aY]R i 1}R .•i[IRVF.Y rS rYR} ,fF2T. 9JPLEi<a170N3 raR rfffSSIJa YAiPE 3ASSA 0,1'WCSEf CP3 EL8YA7f(M' or sue.. o• ov rr>a srxnNe .s2• oaaxcu oP secrrcN s, n rev.: AwacMr.•r aw car 4.J i/"c XC.',Vcrc.'.VO WArSk lfx'nTF.aHY an+eas. 5.l Rp5 •g Tp Mf;�nptiAm o0ls"AaMESbril Ttl ALYSPlr f! r[VxMe.Vr[LYNIfPtiaTAxt]DOkS HOTMEM'&'iEA'rA 7RL8 &E.ViCX Ir9 71m=sr,-R�E�CY+nR xy �i¢'LfRF SLM2Y ^ ✓xem. i�rc ar RSE rxafTXrl' Sm nSTpMlfnf6 a%�YRRSM? (ZYffAIrBE[IPT' wfflf An e�mxc rwxrARGZ� ae ss�'.�,rracw m�rrr�.a�s aFFacnen F!£l.'riML ills. P.aRC£:. w A€aaenfMo ro ow-0RAtt. uw. Ywr naarm"vureA r+nu ACnUY LQOHAM•DHABCTX n aS.`YJel'aY R'rlMx niFES Y8RP5 A Y r rIR.4rLY9CY_VSA 5LY3Y a91E . IN NO SYRAaNAY AMYACrKM Li43M U t-rmAN-iH I A-RAPVr.Y- r.YW,I@Jk1F11 Nf)M!! - M.YYEARS FkGN. RA M 0 F CERITFK.1M.N S�rQW'/+fR• V SURVE roR•S srasPwsnrr f. FafNAE.', U �TF, 4 MSEA UNt ,1,ZLAW90r7MffA1EOF f(EIPFPY(1177r➢Y 11fATTHS Snx LEY 4R,111N M REQM WAS DAY. Hr ae•-v Mr nrR BKiMAxn vr£r'RMV rryAr rrf6J[AP r A revs MIRESSIRAPW? .WAM C. BOOKCL ,rnMwL#� E G3,4CL YS6nwgS fMG c -2 < d 3 VINCINITY AERIAL MAP Design Calculations OWTS The design flow is calculated as follows for the total waste flows of the from the existing single family residence. The waste flow from the existing residence has been served by an OWTS permitted at the time of county permit in 2008, under County ISDS permit No. 4419 to serve the existing 2-bedroom residence. This design is for the replacement of the older chamber trench system that is currently compromised due to assumed partially clogged soils. The system is exhibiting slower infiltrative capacity and reduced recovery, therefore in need of replacement. The existing functioning 1000 gallon two compartment concrete septic tank has been pumped a few times in recent years and is equipped with sanitary tees and concrete risers with lids installed at the surface. The upgrade design utifizes the existing tank with the addition of new 1000 gallon septic/dosing tank with high head pump biotube vault assembly to discharge to new full pressure dosed chamber trenches sized for 4-bedroom capacity usage. The two existing chamber trenches were installed approximately 6 feet below the surface and will be abandoned in place. The treatment capacity for the repiacement system is designed for a minimum 3-bedroom residence adequate for the existing 2-bedroom single family home that will provide additional �] capacity for additional usage as needed. From the Regulation 43 usage table: f� Minimum population based on 2 person per bedroom for the first 3 bedrooms = 6 persons for a total of 6 persons usage. Gallons per day per person =75 gai/person/day, No peaking factor co Max. Design flaw (Qd)gallons/day = (# of people} x (avg. flow)gal/person/day. CO w� r Design flow Qd = 6*75=450 gpd LU p CD w = U o Septic / Dosing Tank Design: w [I] L CD z The septic tank capacity required for a minimum 48 hour retention time is calculated as follows: f--I < r- CD Q ❑ V = 450 gal/day * 2 = 900 ga llons. Continue use of the 1,000 gallon, two compartment concrete z r- septic tank with an inlet/outlet sanitary tees and existing riser/lids, Install an effluent filter In CD M the outlet sanitary tee in the second chamber. intal! a 500-gallon effluent dosing in series r� Li adjacent to the existing septic tank and set with inlet approximately 4" lower then existing tank 1 g p pP Y g I < U outlet pipe invert. Tank shall be installed with with a PVC ribbed riser and fiber !id a the finish r--I � g rode surface. � � III 5ub Surface Conditions and Testing: A subsurface soil investigation and site assessment was performed by Sopris Engineering in on November 19, 2020. The sails in the proposed field envelope area were sampled and characterized by application of the USDA visual/tactile s0 texture method analysis. The SOILS below 12 inches of topsoil/fill material consist of medium dense clay loam soil with less than 2% scattered gravel or rock content to 7 feet below the surface grades. The soils appear to be consistent across the site from observations in the excavated profile pits. The native soils sampled from 2-3 feet below the surface are characterized as a soil type 3 Q ❑ CV a o consisting of clay loam texture with fine granular structure. This soil has an effective loading r rate for conventional soil treatment of 0,35 Gal/S.F./day for a levei 1 conventional treatment } system. The equivalent percolation rate is assumed to be 40-60 minutes per inch. No free water o7 � was encountered in excavations on site. Seasonal high Groundwater levels are expected to be below 10 feet from the existing surface grades. The soils are suitable for a conventional shallow absorption field consisting of pressure dosed gravelless infiltration chamber units in a trench configuration. Treatment -Soil Treatment Unit/Absorption System Design- The treatment/absorption field is designed based an utilizing the effectiveLong Term rm Acceptance Rate (LTAR) for the native soils and the application of appropriate loading factors for a soil treatment unit system utilizing pressure distribution to full pressure dosed gravelless chamber trenches. The new treatment system and absorption field will consist of pressure dosed distribution of septic tank effluent via a high head pump assembly to individual chamber, trench custom perforated distribution laterals with treatment across the native coif absorptive surface below the placed leaching chambers. z 0 Long Term Acceptance Rate (LTAR) Considering the application of the state regulation 43: W Receiving Wastewater Treatment Level 1; Soil type 3 loading rate for a clay loam is (0.35 iY gal./5.F.jday).; Loading factors; (Table 10-2, pressured dosed trenches = 0.8) and (Table 10-3, Chambers Category 3 = 0.7) A(sf) = Qd x L.F,1 x L.F.2 .: A = Area; LIAR LTAR = 0.35 Gal/S.F./day for clay loam Qd = flow (gal/day) = 450 gpd L.F.1=0.8 full pressure dosed trenches Distribution L.F.2=0.7 Chambers Category 23 A(sf) = 525 gpd x 0.8 x 0.7 = 840 S.F. 0.35 Gal/S.F./day Number of Quick-4 Infiltrator chambers 4'x3'x12"chambers: 840 S,F = 70 infiltrator Quick-4 chambers; Use 72 chambers z 12 S.E./Chamber LU Number of 5'x3' Bio-Diffuser chambers: 700 S.F = 48 chambers; Use 48 chambers Z 15 S.F./Chamber Use 72 Quick-4 Infiltrator chambers in four trenches 74' long by 3' wide with 18 chambers 0units per trench plus two end caps as delineated on the plan or equivalent Bio-Diffuser chamber trenches. The septic tank effluent will be pressure distributed to the head of each chamber row Fn via individual distribution pipes roman ADU pressurized bya head head pump biotube w discharge assembiy in a the dosing comparment of the 1000 gallon tank. ry LL � w (D Z X a QU o [�i) 0 JW d o J IL O J :z w N LL w d N Z w Q o 0 Z N ❑ � PQ �� U LLJ 1- • L A� 22l837�7 J LJ - • V . 1 1 L< LLJ ��/,� • NAL V1� � I- E_ 0 w 0 U) CO p H J J o DATE: 03 - 08 - 2021 JOB NO. 30211.01 �tE�sEE ur Es ,.: 2020y30211-WILCOX1,CNIL\CIVIL DWGS\DE�30211-DE-OWTS PLAN DWe5W Marlu2s, 2Q21-10:55art SHEET C-1