HomeMy WebLinkAboutMechanical Engineer Calculationsr%eáazroo-/
RËscheck Software Version 4.7.L fu7ne%S âL*/ot4àn
Compliance Cert¡f¡cate,%úe./<
Project Anderson Residence
Energy Code:
Location:
Construction Type:
Project Type:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Perm¡t Number:
Construction Site:
278 Ronce Lane
Carbondale, CO 81623
2009 rEcc
Carbondale, Colorado
Single-family
New Construction
5,488 ft2
23o/o
s (7313 HDD)
Owner/Agent:Designer/Contractor:
Kelleigh Condon
Michael Fuller Architects
23400 Two River Road, Suite 41
Basalt, CO 81621
9709276620
kcond on@mful lera rch itects.com
0
t2 I27 1
30290
Cornpliance: Passes r,rsing UÂ trede-off
Compliance: 2,¿7o BetterThan Code Maximum UA: 1282 Your UA: 1251
The 0/6 Better or Worse Than Code lndex reflects how close to compliance the house ¡s based on code trade-off rules.
It DOES NOT prov¡de an estimate of energy usê or cost relative to a minimum-code home,
Envelope Assemblies
ABOVE GRADE WALL: Wood Frame, 16" o,c,
GLASS WINDOWS: Metal Frame:Double Pane with Low-E
GLASS DOORS: Glass
SOLID DOORS: Solid
BELOW GRADE WALL: Solid Concrete or Masonry
Wall height: 1L.0'
Depth below grade: LL,0'
lnsulat¡on depth: 1L.0'
SLAB ON GRADE: Slab-On-GraderHeated
lnsulation depth: 6.0'
FLOOR OVER CRAWL: All-Wood Joist/Truss:Over Unconditioned Space
SLOPED ROOF: Cathedral Ceiling
FLAT ROOF: Flat Ceiling or Scissor Truss
6,082
L,234
t72
274
732
260
432
60
96
35
20.0 0.0
13.0 0.0
0.059
0.350
0.3s0
0.3s0
0.048
0.684
0.033
0.027
0.030
r50
84
rt7
t7
220
2,536
4,347
s80
30.0
38.0
38.0
10.0
0.0
0.0
0.0
Project Title: Anderson Residence Report date: }].DLDT
Data filename: J:\Jobs\2020 -Jobs\20042.0O - Anderson Residence\Mechanical\Calculations\20042 Page 1 of 8
Anderson Residence REScheck.rck
gØrt t'^+o lqsw+;chu
Cavity
R-Value
Coñt.
R-Value
Gross Area
Per¡meter
orAssembly U-Factor UA
Compliance Staternent' The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in
REScheckVersion 4.7.1 and to comply with the mandatory requirements listed in the REscheck lnspection Checklist.
Signature Date
Project Title: Anderson Residence Report date: 0u2ll2l
Data filename: J:\Jobs\2020 -Jobs\20042.00 - Anderson Residence\Mechanical\Calculations\20042 Page 2 of 8
Anderson Residence REScheck.rck
RËScf¡eck Softwêre Version 4.7.L
lnspection Checklist
Energy Code: 2009 IECC
Requirements; 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Add itional Com ments/Assum ptions:
Project Title: Anderson Residence Report date: 0]-l2]..l21,
Data filename:jr\Jobs\2020 -Jobs\20042.00 'Anderson Residence\Mechanical\Calculations\20042 Page 3 of 8
Anderson Residence REScheck, rck
Section*
& ies,llt Pre-l nspection/Plan ßeview Plans Veriñed
Value
Fleld Verlfied
Value
103.2
lPRr.ll
v
; Construction drawings and
; documentat¡on demonstrate
;energy code compliance for the
:building envelope.
res
N ot
Not Observable
Not icable
; Construction drawings and
i documentation demonstrate
ienergy code compliance for
;lighting and mechanical systems.
i Systems serving multiple
:dwelling units must demonstrate
;compliance with the commercial
i code.
103.2,
403.7
lPR3l1
#
Complies
Does Not
Not Observable
Not Applicable
;Heating and cooling equipment is I Heating:
sized per ACCA Manual S based ; Btu/hr_
on loads per ACCA ManualJ or j Cooling:other approved methods. i etunr]_
Heati ng:
Btu/hr
Cooling
Btu/h r
403.6
IPRzl2
si ENot Observable
[JNot Applicable
1 High lmpact (Tier r)2 Medium lmpact (Tier 2)3 Low lm act (Tier 3)
Sect¡on
#
& Reo.lD
For¡ndatisn lnspection Plans Verified
Value Complies?Fleld Verified
Val¡¡e Comments/Assumptions
402.t.1
lFollr
.*
flComplies
EDoes Not
ENot Observable
ENot applicable
Slab edge insulation R-value R-R-
n Unheated
! Heated
n Unheated
! Heated
See the Envelope Assemblies
table for values.
303.2,
402,2.8
lF02l1
&)
Slab edge insulation installed per
ma nufacturer's ¡nstruct¡ons,
Complies
Does Not
Not Observable
Not Applicable
402.t.t
IF03]1
'&.
iEComplies
'Eoo"s
ruot
,Elrlot Observable
:ENot Applicable
ft ftSlab edge insulation
depth/length.
see the Envelope Assemblies
table for values.
Conditioned basement wall
insulation R-value. Where interior
insulation is used, verification
may need to occur dur¡ng
lnsulation lnspection. Not
required in warm-humid locations
in Climate Zone 3.
R-R-402.1.r
lF04l1
tt'
IComplies
ÜDoes Not
!Not Observable
ENot Applicable
See the Envelope Assemblies
table for values.
303.2
lFo5l1
*
Conditioned basement wall
insulation installed per
man ufacturer's ¡nstruct¡ons.
Complies
Does Not
Not Observable
Not Applicable
402.2.7
lF06l1
.*'
i Condit¡oned basement wall
iinsulation depth of burial or
:distance from top of wall,
ft ft
:nNot Observable
Eruot cableAppl
plies
Not
see the Envelope Assemblies
table for values.
A protective covering is installed
to protect exposed exter¡or
insulation and extends a
minimum of 6 in, below grade.ENot Observable
ENot Applicable
Not
tes
Complies
Does Not
Not Observable
Not Applicable
Additional Com ments/Assum ptions:
Project Title: Anderson Residence Report date: 0Ll21,l2L
Data filename: J;Vobs\2020 - Jobs\20O42.OO - Anderson Residence\Mechanical\Calculations\20042 Page 4 of 8
Anderson Residence REScheck.rck
1 h lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low I (Tier 3)
Se(tloã:,. * :,.
É ReoJD
402.1.1
402.3.4
lFRll1'*
Door U-factor U.U-
Does Not
Not Observable
Not Applicable
See the Envelope Assembl¡es
table for values.
plies
402.r.L,
402.3.L,
402.3.3,
402.5
lFR2li
,e
u-_U-plies
Not
ENot Observable
Applicable
Glazin g U-factor.(area-weighted
average).
See the Envelope Assemblies
table for vâlues.
303.1.3
lFR4ll
.b
U-factors of fenestration products
are determined in accordance
w¡th the NFRC test procedure or
taken from the default table.
EComplies
EDoes Not
ENot Observable
ENot Applicable
402.4,4
lFR2oll
'&
Fenestration that is not site built
is listed and labeled as meeting
AAMA /VDMA/CSA 1 0 1/1.S.2/4440
or has infiltration rates per NFRC
400 that do not exceed code
limits,
Complies
Does Not
Not Observable
Not Applicable
lC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate <2,0 cfm
leakage at 75 Pa.ENot Applicable
plies
Does Not
Observable
403.2.t
lFR12l1
.&
Supply ducts in attics are I
insulated to >R-8. All other ducts ;
in unconditioned spaces or :
outside the building envelope are i
insulated to >R-6, t
EDoes Not
ENot Observable
ENot Applicable
R-R-
R-
plies
R-
403.2.2
lFR13l1
'&
All joints and seams of air ducts,
air handlers, filter boxes, and
building cavities used as return
ducts are sealed.
EComplies
EDoes Not
ENot Observable
Not Applicable
403.2.3 ;Building cavities are not used for
lFR1513 ìsupply ducts.
Complies
Does Not
Not Observable
Not Applicable
HVAC piping conveying fluids
above 105 qF or chilled fluids
below 55 oF are insulated to >R-
3.
,EComplies
:EDoes Not
lENot observable
:ENot Applicable
R-R-
.[JComplies
,f]ooes Not
iElttot observabte
:ENot Applicable
R-R-Circulating service hot water
pipes are insulated to R-2.
, Automatic or gravity dampers are
, installed on all outdoor air
. intakes and exhausts,
EComplies
EDoes Not
üNot Observable
Not Applicable
Add itional Comments/Assumptions:
Project Title: Anderson Residence Report date: ü,l2ll2l
Data filename:J:\Jobs\2020 -Jobs\20042.00 - Anderson Residence\Mechanical\Calculations\20042 Page 5 of 8
Anderson Residence REScheck. rck
1 hlm (Tier 1)Medium lm (Tier 2)3 Low lm (ïier 3)
Section
#
& ieo.lD
Plans Verified
Value Co$rmsnts/Ãssumptions
303.1. :All ¡nstalled insulation is labeled
{lN:.3J2 ,or the installed R-values
.V; :Provided'
Complies
Does Not
Not Observable
Not Applicable
402.r.1,
402.2.5,
402.2.6
llN111
.#
Floor insulation R-value.R-R-;EComplies
,EOo". Itlot
jEruot Observable
:Eruot npplicanle
! Wood
fl Steel
! Wood
fl Steel
See the Envelope Assemblies
table for values.
303,2,
402.2.6
lrN211
$þ
Floor insulation installed per
manufacturer's instructions, and
in substantial contact with the
underside of the subfloor,
mplies
EDoes Not
f]Not Observable
Ettot icable
402.t.I,
402.2.4,
402.2.5
ilN3lr
'e,
Wall insulation R-value. lf this is a
mass wall with at least % of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies.
R-_
! Wood
I Mass
! Steel
R-Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.! Wood
! Mass
! Steel
303.2
llN4l1
&
Wall insulation is installed per
manufacturer's instructions.
Additional Comments/Assumptions:
Project Title: Anderson Residence Report date: OLl2Ll2I
Data filename: J:\Jobs\2020 -Jobs\20042.O0 - Anderson Residence\Mechanical\Calculations\20042 Page 6 of 8
Anderson Residence REScheck. rck
1 Hi h lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low I (Tier 3)
402.t.L,
402.2.t,
402.2.2
IFti.]1
*
Ceiling insulation R-value. Where
> R-30 is required, R-30 can be
used if insulation is not
compressed at eaves. R-30 may
be used for 50Q ft2 or 20o/o
(whichever is less) where
sufficient space is not available,
lEComplies
,EIDoes lrlot
iElrlot Observable
iENot Applicable
t
R-R-:_
! Wood
! Steel
Wood
Steel
See the Envelope Assembl¡es
table for valuei.
303.1.1,1",
303.2
lFt2l1
*
Ceiling insulation installed per
manufacturer's instructions.
Blown insulation marked every
300 ftr.ENot Observable
Eruot Applicable
lies
Not
402.2.3
lFt3ll
*
Attic access hatch and door
insulation >R-value of the
adjacent assembly.
R.R-
;tr:¡
:EComplies
¡EDoes Irlot
Not Observable
Not Applicable
lverified by blower door test result
iof <7 ACH at 50 Pa. Th¡s
;requirement may instead be met
jvia visual inspection, in which
jcase verification may need to
I occur during lnsulation
ACH 50 =ACH 50 plies
Not
2, ;Building envelope tightness
402.4.2.t
lFl].7]1
*Observable
Applicable
or sL2 cfm across syStems. Or,
rough-in test result of <6 cfm
across systems or <4 cfm
without air handler. Rough-in test
verification may need to occur
during Framing lnspection.
cfm cfm
;ENot applicable
Post construction duct tightness
result of s8 cfm to outdoors,
403.2.2
lFt4l1
ü
EComplies
EDoes Not
ENot Observable
plies
Not
Programmable thermostats
installed on forced air furnaces
Observable
Applicable
ElComplies
ElDoes Not
ENot Observable
ENot npplicable
Heat pump thermostat installed
on heat pumps.
Circulating service hot water
systems have automatic or
accessible manual controls,
Does Not
Not Observable
Not Applicable
plies
404.!
lFl6l1
*
plies
Not
50o/o of lamps in permanent
fixtures are high efficacy lamps.
Observable
Applicable
EComplies
EDoes Not
ENot Observable
Etrtot Applicable
Compliance certificate posted
Manufacturer manuals for
mechanical and water heating
equipment have been provided,
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumpt¡ons:
Project Title: Anderson Residence Report date: 0rt2]-t2L
Data filename:J:\Jobs\2020.Jobs\20042.OO - Anderson Residence\Mechanical\Calculations\20042 Page 7 of 8
Anderson Residence REScheck.rck
1 hlm (Tier 1)Medium lm ct Low lm ct (Tier 3)
1 hlm ct fiier ].)Medium lm (Tier 2)Low lm (Tier 3)
Project Title: Anderson Residence Report date: 0Ll2Ll2l
Data filename: J:\Jobs\2020 - Jobs\20042.0O - Anderson Residence\Mechanical\Calculations\20042 Page 8 of 8
Anderson Residence REScheck.rck
2009 IECC Energy
Eff¡cien cy Cert¡f¡cate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating System:_
Cooling System:_
Water Heaterr
Name:
Comments
20.00
13.O0
30.oo
38.OO
o.35
o.35
Date:
lnsulation Rating R-Value
Glass & Ðoor Rating U.Factor SHÊC
Heating & Cooling Equipment Efficiency