HomeMy WebLinkAboutHigh Strength Bolt Inspection Report 03.02.2021West Slope Testing & Inspection LLC Report # 1
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Date: 3-2-21
Project: Lot 8 Coulter Creek Ranch
Address: 176 Fisher Creek Ln. Carbondale, CO
Building Permit No: BLRE-09-20-6508
General Contractor: WRW Log Works
Contractor that Performed Work: Black Magic Welding
Inspection of shop fabrication or field work at job site: Field
Report: Inspected the high strength A325 bolting at the steel beam & column
connections for the structural steel framing on the project except for one steel
beam & column that was not yet installed close to grid line 3 between grids B &
D. Visual weld inspection was also performed at the field welded column cap &
base plate connection welds.
The onsite welding & high strength bolting inspected above appeared to be in
substantial conformance with the plans, and the quality requirements of the AWS
D1.1 Structural Welding Code & the AISC/RCSC Specification for high strength
bolting.