HomeMy WebLinkAboutOWTS Installation Observations 03.25.202133 Four Wheel Drive Road Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com March 25, 2021 Project No. C1544 Uriel Payan payanbuilders@hotmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations – Septic Tank Only 332 Meadow Lane Garfield County, Colorado Permit Number SEPT-08-20-6455 Uriel, CBO Inc. observed the installation of the septic tank on October 29, 2020 for the subject property. You, the property owner, installed the system. The original OWTS, documented by Garfield County Individual Sewage Disposal Permit Number 1526, was designed to accommodate 3 bedrooms and received final approval on November 10, 1986. A shop with a bathroom (toilet and sink) has been constructed and is an auxiliary use to the residence. A remodel to the residence changing the footprint and construction of the shop necessitated installation of a new septic tank. The existing septic tank was pumped and removed. New, 4-inch diameter SDR-35 sewer lines with double-sweep clean outs were installed from the residence and from the shop with a minimum 2% fall to the new septic tank. The installation included a new, 1000-gallon, two-compartment Roth® poly septic tank with an effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. A new 4-inch diameter SDR-35 sewer line ties the new septic tank to the existing STA. At the time of connection, the existing sewer line to the STA was found and was broken. With the new connection to the STA, the system has been working property with no sign of saturation or ponding. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, CBO Inc. Carla Ostberg, MPH, REHS Inlet pipes entering septic tank. Outlet pipe with effluent filter. Handle extension must be added if more than 1-foot of riser is installed on the tank. Effluent filter must be cleaned annually, or as needed. GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 8th Street Suite 309 Glenwood Springs, Colorado 81801 Phone (903) 945 -8212 This does not constituteINDIVIDUALSEWAGEDISPOSALPERMIT ,$q,1526 a building or use permit. Owner TJwro Inc. System Location 0332 N1 allow Lane, Glenwood .Springs, Licensed Installer Self Conditional Construction approval is hereby granted for a OO C) gallon L_ Septic Tank or —Aerated treatment unit. Absorption area (or dispersal areal computed as follows: Pere rate of one inch in 6 minutes requires a minimum of 4 / sq. ft. of absorption area per bedroom. Therefore the no. of bedrooms 7 x / 6 / sq. ft. minimum requirement = a total of reU'q. fL of absorption area. May we suggest: 2,_ K 4- / X 3 2 f f$ or- 3 27 K 3 'c - / ,e, t.., T - Date r 7 /c, : ( 4:'Inspector yi 2 c6 % G4 4 ,I i FINAL APPROVAL OF SYSTEM:i No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to cover•ing any part. cr)i< Septic Tank access for inspection and cleaning within 12" of ground surface or aerated access ports above ground OK surface. Az. , Proper materials and asse / /pl y.....b Trade name of septi tank or aerated tfeatmntt unit ) p 'ILL. 0 44 c ' V/ Ve 6 ' Jiil 0 /, fr Adequate absorption (or dispel sal) area. 0 ' ` Adequate compliance with permit requirements. S2 Adequate cornpliance with County and State regulations /requirements, Other Date h 0 Inspector __ yi? RETAIN WITH RECEIPT RECORD 'CONSTRUCTION SITE CONDITIONS: 1. All Installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit Is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or Installs an Individual sewage disposal system In a manner which involves a knowing and material variation from the terms or specifications contained In the application of permit commits a Class I, Petty Offense500.00 fine — 6 months in jail or both.). Applicant: Green Copy Department: Pink Copy INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION Approval by OWNER L County Official: A DDRESS wofi", PHONE y6 3 - 3,5 • CONTRACTOR7 pADDRESS, /3o ( c $ o/ (?/64C4. PHONE b3-0,n7 PERMIT REQUEST FOR: New Installation Alteration Repair Attach separate sheets or report showing entire area with respect to surrounding areas,topography of area, habitable building, location of potable water wells, soil percolationtestholes, soil profiles in test holes. See page 4.) LOCATION OF PROPOSED FACILITY: County (g, f4?iZ Near what City of Town 67AFnJec arr2D, ,4.Lot Size ticet' Legal Description 4 023 A2I 3 l Jsr13/l.U WASTES TYPE:x) Dwelling Transient Use Commercial or Institutional Non- domestic Wastes Other - Describe BUILDING OR SERVICE TYPE: Pe%F_,UTjy( Number of bedrooms Number of persons Garbage grinder c Automatic washer dishwasher SOURCE AND TYPE OF WATER SUPPLY: well spring stream or creek Give depth of all wells within 180 feet of system: If supplied by community water, give name or supplier:djl(iev------,91,J.01;ce GROUND CONDITIONS: Depth to bedrock:o? yyDepthtofirstGroundWaterTable: C'.,l/jy,{/ Percent ground slope: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:44J(— Was an effort made to connect to community system? TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: X) Septic Tank Aeration Plant Vault Vault Privy Composting Toilet Recycling, potable use Pit Privy Incineration Toilet Recycling, other use Chemical Toilet Other - Describe: FINAL DISPOSAL BY: Absorption Trench, Bed or Pit Evapotranspiration Underground Dispersal Sand Filter Above Ground Dispersal Wastewater Pond Other - Describe: WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? Page 2 t. PERCOLATION TEST RESULTS: To be completed by Registered Professional Engineer.) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No._Name, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon suchfurthermandatoryandadditionaltestsandreportsasmayberequiredbythelocalhealthdepartmenttobemadeandfurnishedbytheapplicantorbythelocalhealthdepartmentfor purposes of the evaluation of the application; and the issuance of the permit is subject tosuchtermsandconditionsasdeemednecessarytoinsurecompliancewithrulesandregulationsadoptedunderArticle10, Title 25, C.R.S. 1973, as amended. The undersigned hereby certifiesthatallstatementsmade, information and reports submitted herewith and required to besubmittedbytheapplicantareorwillberepresentedtobetrueandcorrecttothebestofmyknowledgeandbeliefandaredesignedtobereliedonbythelocaldepartmentofhealthinevaluatingthesameforpurposesofissuingthepermitappliedforherein. I further under- stand that any falsification or misrepresentation may result in the denial of the applicationorrevocationofanypermitgrantedbaseduponsaidapplicationandinlegalactionforper-jury as provided by law. l gDatej6 6 Signed 2 -07( PLEASE DRAW AND ACCURATE MAP TO YOUR PROPERTY 0 2 Goy i.0 d ge . cp Qs,n Page 3 or PLOT PLAN AND DESIGN FEATURES: Include by measured distance location of wells, springs, potable water supply .lines, cisterns, buildings, property lines, subsoil drains, lake, water course, stream, dry gulch and show location of proposed system by direction and distance from dwelling or other fixed reference object, and additional submissions in support of this application such as data, plans, specifications, statements andcommitments. 1 V 2134 air. /5 b0 t 40# 199 Fail 3Wad- 8a44,11 8g Page 4 Garfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT-6455 Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 9/21/2020 Expiration Date 9/21/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address 332 Meadow Ln. Glenwood Springs, CO Parcel No. 218535403023 Owner Name Uriel Payan Designed By Carla Ostberg of CBO Inc. Contractor Payan Builders Inc. Owner Phone (970)319-4101 Designer Phone (970)309-5259 Contractor Phone (970)319-4101 Number of Bedrooms 3 Minimum Tank Capacity 1,000 Minimum Absorption (Existing) Permit Conditions: This OWTS Permit is approved on the condition of compliance with the application and design documents as submitted by CBO, Inc. dated September 4, 2020. Changes must be approved by Garfield County Public Health and the designer prior to construction. The existing septic tank at the property will be replaced with a new 1,000-gallon, two -compartment septic tank with an effluent filter on the outlet tee. A new auxiliary building with a bathroom will connect into the OWTS. A remodel is also proposed that will extend the residence 20-feet to the north and will not add any bedrooms. The existing system was permitted as ISDS 1526 on 11/10/86. The existing system was designed to accommodate 3 bedrooms, and continues to serve the existing 3-bedroom, single-family residence. Based on information provided, the proposed use is not determined to increase flow under current regulations. This permit approves connection to the existing soil treatment area with the understanding that the system is in working order and that the existing system is adequately designed and constructed for the same permitted residential use. If at a future date repairs are needed, the system demonstrates signs of failure, or if use is increased (such as an additional bedroom in the residence or commercial use), the system must be upgraded or replaced according to Garfield County OWTS Regulations applicable at the time of permitting. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. r`1 n i'Y\V_, September 21, 2020 Issued By: Garaield County Environmental Health Department Date 832‐R‐13‐002