Onsite Wastewater Treatment System Design
4-BR Single Family Residence
February 2021
Prepared for:
Marcelino Holguin
County Road 218 Address TBD
silt, co 81652
Proposed 4-BR Single-Family Residence
County Road 218 Address TBD
silt, co 81652
Parcel No. 2l 79-023-01 -003
Prepared by:
WestWater Engineering
Dean Goebel
2516 Foresight Circle #1
Grantl Junction, CO I1505
p7ar241"1076 * FAX (e7o) 241-7097
1,0 Site Conditioqs
The onsite wastewater treatment system (OV/TS) will serve a proposed 4-BR single-family
residence on a vacant 2"9-acre parcel located north of Silt, Colorado at CR 218 address TBD
(FigureAl). The new OWTS will use atotal of 72 Quick4& Plus Standard Infiltrators
configured in a single bed using four (4) rows each with eighteen ( l8) Q4 units for a minimum
12' x 751 footprint including chamber endcaps (Figure A2). Proposed soil treatment areas
(STA)ileachfield are located west and north of proposed residçnce adjacent to the soils and
percolation test sites" These proposed STA/leachfield sites are relatively flat lying areas
(approximately 5,560 feet ele¡ation) on an upper bench where the house will be located. The
west STA/leachfield site was chosen to meet the 1Oû-foot minimum setback to the water supply
well proposed for the northern area of parcel.
Soils and percolation data wers collected February 9,2021 by TVestV/ater Engineering iu
accordance with Garfield County On-Site Wastewater Treatment Regulations (Reguiations).
Soil profile in the north percolation test site shows 0-0.9 feet dark yellowish brown sand with silt
overlying 0.9-8.0 feet of brownish yellow sand with thin clays sand lenses at maximum depth of
excavation. The west test site shows a unifonn profile of alluvium with yellowish red sandy
matrix supporting well-rounded pebble- to small bounder-sized clasts from the surface down to
8.0 feet. Groundwater wâs not encountered in either of the 8.0-foot soils observation pits. Based
on hending antecedent sail moisture conditions with depth'and the laok of redoxirnorphic
features indicative of prolonged saturation, estimated high seasonal water table is greater than
8.0 feet. Percolation testing results for test holes completed in the sand with silt and lenses of
clayey sand range from 14 to 46 minutes per inch (min/in) and the alluvium 7 to 48 minlin
{Appendix A).
Based on soil texture, structure and percolation rates, site soils slated to be used as infiltrative
surface {2- to 4.foot depth interval) for received rvastewater are classified as Soil Type 2 in
accordance with the Regulations. Long-temr acceptance rate (LTAR) used to design the OWTS
(Table l0-1 Regulations) is 0.60 gallons per day per square foot area (Wdl#).
2.0 V/astewater Flows
Averaqe flow
Maximum Daily Wastervater Flow (gpd): 4 bedroom roorn dwelling
4 x 150 gptl/betln.rom = 600 gpd
Septic Tank
Septic tank capacity (Table 9-1 Regqlations) requires a 1,25t gallon miniurum septic tank to
serve proposed 4-BR dwelling. Septic tank capacity also comesponds with a 48-hour
rletention tirne fur design wâstewater flolv (2 days x 600 gpd = 1,2AA gallons). The proposed
1,250 gallon septic tank meets these sizing requirements.
1
For 4-BR dwelling septic tank capacity must be > 1,250 gallons; use a two*
compartment sepfic tank approved for use in Garfield County.
3.0 OWTS Desisn
Sa¡d with silt or alluvium occurring at the 2.0 to 4.û-foot depth interval will be used for upper
infilhative surface for proposed STA (Figure A3). The maximum 4.0-foot soil depth promotes
optimal secondary effluent treatment using oxygen, bacteria and fungi processes. Bed
excavation will remove any sparuo vegetation and root mass to prepare level su¡face f'or
installing infiltrators on receiving soil surface providing secondary treahnent of discharged
wastewater. Soil should not be wet at time of excavâtion. Sand with silt or alluvium (try to
segregate out clasts larger than gravel size) used'to cover STA tnust be slightly crowned over
proposed bed to pfomote water runoff and prohibitponding over aüy area of STAlleach{ield.
Prior to backfilling, cover in{iltrator units with woven geotextile fabric or similar material to
prohibit soil intrusion.
All setback distances in accordance with the Regulations are applicable to septic system
installation. The new 1,250 gallon septic tank rnust be at least 5 feet and STA 20 feet from the
proposed residence. STA's must be outside any easements and at least l0 feet from property
lines and at least 25 feet from potable water lines and furrow irrigation. The STAlleachfield,
including proposed repair leacåfield âreas, must be at least 100 feet from proposed water supply
well in the northeln portion of parcel and 50 feet Ílom surface water including the lake located in
the nor"thwest parcel corner.
The proposed new 1,250 gallon septic tank will provide at least 48 hours detention time for
influent wastewater flow from the proposed 4'BR dwelling. Internal septic tank inlet and outlet
tees must be installed per Regulations. An optional effluent filter may be installed instead of tee
on ths septic tank outlet. Use the Orenco Systems Biotube Effluent Filter OSI Model FTW0444-
36, Effluent filters typically require cleaning asd maintenance every 6 months.
The following design calcu-lations propose to discharge septic tank effluent to one (1) Quick a
Infiltrator Bed comprised of four {4) rows each with eighteen {18) units for a minimum disturbed
ârea approximately 12 feetby 75 feet. A total of 72 Quick 4 Standard Plus Infilhator units will
be installed in a single bed conüguration.
$,-çil.Absorptiqn Area Calculations
,Absorptian Area {A) = Design Flow {Q)/LTAR
Field percolation rate {t): 7 to 48 midin
Absorption Field Area: 6: Q/LTAR,
2
Where:
A: Drainfield area square feet
Q = Design Flodmaximum daily wastewater Ílow
= maximum daily wastewater flow of 4*BR dwelling
* 4 x i50 gpdrbedroorn:600 {gpd)
LTAR * Long Term Aceeptance Rate (max. hydraulic loading rate)
= û.6û gallons per day/ftz
A = 600 gpd/0.60 g¡rd/ft2 : 1,000 ft2
Ouich4 Bed Configuration:
1,000 ft2 x 1.2 (appl. method adjustmentl) x 0.7 {distribution media adjusfmentz) : 840 ft2;
840 ftz /12 ft7 :7t Q4 units; Use 72 units.
I Regulations Table T0-2 size adjustrnent f¿ctor for Methods of Application il STA
2 Regulations Table 10-3 size adjustrnent factor for Types of Media in STA
Note: County ând State approved bottom chamber area fo¡ Quick 4 Plus Standard hrfiltrator Unit
* 12#.
The one (1) Quick 4Infiltrator Bed will use a total of seventy-two (72) units, The bed will have
four (4) rows each with eighteen (18) Q4 charnber units. V/astewater flow into the proposed
single infiltrator bed system will equally split using a distribution box.
4.0 $ystem Itstallation Requirement
Minimum sêtback requirements must be in accordance with the Regulations. All sewer pipe
couplings must be completed withprimed and glued or bell and spigot joints using 4-inch SDR
35 PVC pipe. Schedçle 40 PVC 4-inch pipe with a minirnum 1-foat soil cover must be used if
pipe is installed in a vehicular traffic crossing. Drain-waste-vent (DWV) Schedule 40 PVC pipe
is specified f.or crossings but may also be used instead of SDR 35 PVC pipe.
Building sewer pípe must bc set al a slope between %-inch and 7¿-inch per foot slope (1 to ZYo),
preferably using the t/¿-inehpor foot slope as recommelded by the International Plurnbing Cocle
(lPC) as adninistered by the County. Fittings should use sweep 90-degee curves or twc (2) 45-
degree elbows at all influerrt pipe turns. Fittings must be DWV for Scl¡edule 4û PVC pipe,
Clean-outs (2-way) are required between dwelling and septic tank and beyond septic tank where
pipe lengths exceed i00 feet from septic tank to STA/leachfield.
3
Installer must adhere to minimum depth requirements for leachfield to ensure gravity flow into
proposed infiltrator bed. OWTS components must be placed on native soils or re-stabilized soils
ín excavated areas. STA/leachfield must be sxcavated level to ensure prepared infiltrative
surface is level along entire length of STA.
The owner will ultimately be responsible for septic system maintenance including pumping
septic tank once every 3-4 years and cleaning effluent filter (if opted) every 6 months.
5. 0 Svste. _{n. Inspecti on
WestWater Engineering is responsible for inspecting OV/TS to ensure construction confoms to
design plan and meets all aspects of County Regulations to include:
r Inspect system prior to backfilling including piping and septic system components.
¡ Complete as-built drawing of system.
6.0 Desien Limitations
The OWTS design is based on site specific soil investigation collected in vicinity of proposed
drainfield and local experience of designing O'WTS's in Colorado. The design is only valid for
proposed new OV/TS serving the single-farnily residence at referenced location provided in this
report. West'Water Engineering assumes no liability for inaccurate information or conditions that
vary from design assumptions listed above. Notiff West'Water Engineering and/or the County
regulatory official immediately if actual site conditions differ from those assumed herein.
Please do not hesitate to contact us if you have any questions regarding this report.
Respectfull¡
;"'.. r"t ; ii
| "..", "-tr."*c-
Dean Goebel, M.S., P.G. Hydrogeologist
Reviewed By:
Jeremy Gilliam, P,E
Project Engineer
4
APPËNDIX A
Percolation Data
5
Q\N estlilater En g i neeri n g
4 Consulting Engineers & Scientists
251 6 FOßES|GHT CtRCtE, #1 GRAND JUNCT|ON, COLORADO 8l 505
SOILS AND PERCOLATION REPORT
197or241-7076* FAX (970) 241-7097
Date:
Consultant:
Client:
Land Parcel:
February 9,2021
Dean Goebel, M.S., P.G. Hydrogeologist
WestWater Engineering
251ó Foresight Circle #l
Grand Junction, CO 81505
(e70) 241-7076
Marcelino Holguin
County Road 218 Address TBD
silt, co 81652
Address TBD, Silt, CO 81652
2r79-0n-al-003
SOILS LOG
Site soils were investigaled to collect site-specific data on the vacant Z.9-acre lot immediately
no:1h of East Ballard Avenue, Silt, Colorado. The parcel has not been assignsd an address at this
time by Gar{ield County. Soils and percolation testing was conducted to collect site specific
soils data for a proposed single-farnily dwelling onsite wastewater treatment system (OWTS).
Percolation testing procedures were conducted in açcordance with Garfield County On-Site
Wastewater Treatment System Regulations (Regulations).
The two Percolation Test Sites are located on fhe flat-lying bench north and west of proposed
house site. The north soils and percolation site shows a uniform soil profìle cornprised of sand
and west test site alluvium from surface down to 8.0 feet. The nortli test site is located
approxirnately I 1 5 feet south of the north property line and 1 95 feet east of the west property
line. The west test site is approximately 250 feet soutli of the north property line and I95 east of
the west property line (Figure Al). Although both of these sites are equal distance from the west
property line, the west site is further west than the north site as the west property line is oriented
northeast to southwest.
A-1
Site soils were described and percolation tested in both areas with negligible slope. The west site
is on a crest that slopes approximately l7-l3Yt west towards the west property line. 'fhe location
of this drop offlcut-bank near Cit 218 will require a 25-foot setback in accordance with the
Regulations. The north site is of sufficient area but enoroaches on the 1O0-foot setback from
proposed water supply well in north area of parcel. Setback to the existing lake in the northwest
comÊr of property exceeds the S0-foot minimum for both west and north percolation test sites.
Croundwater \ryas not encountered in either 8-foot soils observation pit; high seasonal
groundwater is estimated to be greater than 8.0 feet,
The soil profile logs are summarized below and in Tables I and lA. Dark yellowish brown
(1OYR 4/4) clayey sand loam with granular structure oçcurs *om 0.0,9 feet overlyìrg dark
yellowish b¡own (1OYR 4/4) clayey sand loam with lenses of sandy clay with granular structure
frorn 0.9-8.0 feet maximum depth of excavation. The west site consists of a unifonn profile of
alluvium with yellowish red (5YR 5/6) sandy matrix supporting well-rounded pebble- to small
boulder-sized clasts. The high seasonal water table estimate of 8.0 feet is based on low
antecedenf soil rnoisture content and the lack of soil colorinfredoximorphic features indicative
of prolonged soil saturation via groundwater.
Table l North Pit Soil Log Description
vf= very fine; f:m: medium and; crs: soarse for sand
Table lA. 1ü9est Fit Soil Log Description
Percolation râtes summarize<l in Tables 2 and 2A. rângc fi'r:rn I4 to 46 niinutes per inch {minlin}
ior the nofih tesf site and 7 to 48 minlin for the west site. A.verage percolation rates for the north
and west percolation test sites are 22 and 26 mirfin, respectively. Basecl on percolation data,
macroscopic tactile soil analysis and estimated depth of the high seasonal water table, the
infiltrative surface of the soil treatment area STA/leachfield can occur along a soil depth interval
Depth Interval (ft)Soil Description
0-0,9 Dark yellowish brown (10YR 4/4) sand {f-vf)' witir silt; low OM;
granular; dry; sage vegetation
0.9-8.0 Brownish yellow 80% (1OYR 6/6) and 20% (10YR 6/8) sand (f-vf) with
Z-inch thick lens at 2' interval of clayey sand {Èvfl; low OM; granular
laminar structure; dry
Ðepth lnterval (ft)Soil Description
0-8.û Alluviurn with yellcwish red {5YR 516} sandy {vÊcrs) sandy matrix
supporting well-rounded pebble- to small boulder-sized clasts; low OM;
granular with laminar clast struch;re; dry; sage vegetatior
A-2
ranging from 2.û to 4.0 feet depth, Site soils are categorizeð asType 2 Soils based on sand
textureso granular laminar structure, and percolation rates predominantly within the l6-25 min/in
percolation rate range. At the time of installing the O'WTS, soils should not be exçavated under
wet conditions to avoid cornpaction and smearing leading to reduction in permeability.
Table 2. North Pit Percolation Test Results
Table 2A,. TVest Pit Percolation Test Results
ID Depth
{ft)
Time Final
Drop
(in)
Percolation
Rate
(min/in)
12:54
(start)
l:09 l:39 2:t9 2:54
(end)
1 2.t-3.0 3.9*3.75*4"375*5.û'5.625"2.62s 46
2 0.0-1.0 4.625"6.0"8.5"10.0"dry 5.3?s t4
J 2.2-3.2 5.0"6.5'o 8.5"1A"25*dry 5.25 14
4 5.0-6.0 3.875"5.0"6.s"',8.0'9-375"5.5 22
5 3.û*4.0 6.75"8.125"10.0-dry dry 3,25 14
ID Depth
(ft)
Time Final
Ðrop
(in)
Percolation
Rate
(min/in)
'10:12
{start)
It:27 10:5:f ll:27 12:12
(end)
6 2.t-3.0 3.25"3.75"4.5"6.0"6.8?5"3.62s JJ
7 û.0-1.û 4. ?5*5.25"6.0"6.5"7,25*?5 48
I 2.Ð,3.0 4.0"4.75"5.5"6.7s',r dry 2.75 27
9 4.0-5.û 5.0u'6.0"dry dry dry 1.0 15
rû 3.5-4.5 4.5"6.75"dry dry dry 2.25 7
Ä-3
FIGURES
FIGURE A3OWTS CROSS SECTIONCR 218 Address TBDNest]{oterEngineering2516 Foresight Circle,Grond Junction, C0 81(s7o) 241-7076#1505.T=USE TOP FACEPLATE PORTCOVER INFILTRATORS WITH WOVEN GEOTEXTILE FABRICCROWN BACKFILLOVER INFiLTRATOR BEDWESTSOILSEXISTINGGROUNDNORTHSOILSSITE3.5'I8'MAXIMUM DEPTH 4.0 FEETMINIMUM DEPTH 2.0 FETTInstollotion Notes:1) Follow Monufocturers Instructionwww.infiltrotorsystems.com2) Screw Pipe Top Port Chomber Foceplote3) Screw Foceplotes ond Units Together4) Instoll Monitoring PortsSCALE1tt:S'50no\otıEorP5?gØa'trcofsì_à<coa
HOLGUIN RES.
COUNTY RD 218
ADDRESS TBD
SHEET:
1 .A
STUDIO M TNGINTTRS, LLC
9TRUCTU RAL CO N9 U LTANT9 DRATTTD tsY: MJB
DESIGNED BY; MJts
DATEr 3.2.2O21
9CALE; A9 Sl-lOWN
25O TRIPP DRIVE
RIFLE
COLORADO BI650
970-366-8690
WOOD
?o91
PLAN
lll lll
10'DlA.
CONC. PIER
CLR,
W/ #4 VERT DWLg
@ QUARTER POINTg
T,A.F
5/8' DIA, EPOfr
RD. (4 EY|BED TO CONC.
10' EÞI|øED 1O COL)
BIÎCH àÊ?era¡ïON
ll
WOOD/ CONCRETE
INTERFACE
3f4"= l'-O"
?AD ?ER,
9CHEDULÊ
T.O.PIER
98|9"
7C'-1C 1/2"
23'-1/4"
¿
tn
Â
Y
I#
96'*1"
29'-Q"8'-C"
T.O.W
:\t
f-
r-
rl.
96'-7"
98'-9.7/8',
aà\h\JI¡sþ(.f¡\fìxl'-'sôâ-,poo0 |*--+þþoIJa6t'wail,a\^Þ\d "ìtÞS çlcno tvç\/3