HomeMy WebLinkAboutConditions of PermitCONDITION o FP ERMIT
BLRE-02 -21-6686
Daniel Daou
Deck & Covered Patio Veranda
1690 High Aspen Dr, Glenwood Springs, Colorado
Lol21, High Aspen Ranch
1) ALL WORK SHALL COMply W|TH THE 2015 INTERNATIONAL RESIDENTIAL CODE
(t.R.c.)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED
IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER
REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) OPEN-HOLE SOTLS REPORT REOUTRED AT FOOTING INSPECTION TO VERIFY 2,000
P.S,F, SOIL BEARING CAPACITY. PROVIDE COPY OF ENGINEER'S REPORT FOR
BUILDING INSPECTOR REVIEW AT FOOTING INSPECTION.
4) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC
BOARD. ELECTRICAL ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION
ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION &
CERTI FICATE OF OCCUPANCY.
5) CONTRACTOR MUST NOT EXTEND CONSTRUCTION PARKING/STAGING OVER THE
SEPTIC TANK/LEACHFIELD. FIELD VERIFY NO IMPACTS.
ó) pRovt D E FU EL-F|RED MAN U FACTU RER',S I NSTALLATION I NSTRUCTIONS, VERIFY
CLEARANCES TO COMBUSTIBLES PER LISTING INSTRUCTIONS; SHALL PROVIDE
GAS SHUT OFF VALVES PER CODE.
7) CAUTION NON-VENTED HEATERS MATNOT BE ALLOWED PURSUANT
MANUFACTURER LISTING SPECIFICATIONS AT ELEVATIONS OVER 5,OOO FT
8) UNVENTED ROOM HEATERS PROHIBITED UNDER GARFIELD COUNry BUILDING
RESOLUTION SECTION G2445, SHOULD PROPOSED VERANDA AREA BE
CONVERTED TO FUTURE ENCLOSED LIVING SPACE, SAID CEILING MOUNTED
PROPANE HEATERS MAY BE SUBJECT TO REMOVAL AND/OR COMPLIANCE WITH
CODES IN EFFECT ATTIME OF FUTURE WORK.