Permit Number SEPT-6758
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 04/13/2021 Expiration Date 04/13/2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 335 Willow Lane, Carbondale, CO 81623 Parcel No.: 239335100009
Owner Name: Sarah Moore Simpson 2001 Trust Owner Phone: (970) 379-6558
Designed By: CBO, Inc. Designer Phone: (970) 309-5259
Contractor: Tim Ha ist Excavation Contractor Phone: (970) 379-9726
Number of Bedrooms: 5 Minimum Tank Capacity: 1,750-gallon Minimum Absorption: 844 ftZ
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated February 13, 2021. Changes to the design and permit must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve an existing four -bedroom residence and a new 1-bedroom ADU. The
system will consist of a new, two -compartment 2,000-gallon septic tank set level with access to
grade with a high -head pump in the second compartment of the new tank. Effluent will be pumped
to an automatic distributing valve set at the high point of the system that will distribute effluent to
850 ftZ of STA. The new STA will consist of two 10' x 42.5' 3-feet deep unlined sand filters, utilizing
secondary sand media. Distribution laterals will be placed on Geomat distribution mats placed
directly on the sand. Distribution laterals are to be 1 % inch Schedule 40 PVC, with 5/32-inch orifices
3-feet on center and the laterals ending in flushing valves at the distal end of the laterals. Inspection
ports are to be installed at each corner of each mound. Maintain all setbacks and elevations as
designed.
Contact the designer and' Garfield County Public Health, at least 43 hours prior to requesting final
inspection of the invstailled system prior to ba•ckfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation, This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.