HomeMy WebLinkAboutOWTS Materials ListItem # llul-í530-2cP l53O Gallon Two Gompartment lnfiltratol@ Poly Tank TANKTOP HALF CONTINUOUS ELASTOMETRIC 175.6"TANK ,NTFR'OR SEAM CLIP (86)TOP VIEW AIJGI{IÆNT DO,YET(a6)TA¡IK BOTTOM HALF 24'ACCESSPORT Tr/cHrträ¡ wfTH LOCKTNG LtO (3)€) up-nelonr SEAM sEcroN DETAIL 4 OUTLETTEE 2f3 TOTAL VOL TOTALVOL ,5" SIDE VIEW SEAM CLIP ¡ Compliont wíth CSA ond IAPMO Stondords¡ PVC risers ovoiloble¡ Secondory sofety screen ovoiloble with PVC riser¡ Moximum buriol depth is 48"¡ Minumum buriol depth is 6"o Tonk is not roted for vehiculor troffic loodingo Exterior of monhole cover includes the following worning: "DANGER ÐO NOT ENTER: PO|SON GASES" LIFT|NGSTRAP GYPTCAT-) END VIEW ffir,n**Ign" I;TTANffiIG, Digging Specs ln vert Dimensions Net Weight Net 16' Long x 7' Wide 43" below inlet :O-à o o èoÊè o o o o èOE' FIBERGLASS SUPPORT f"f' SLOT WALL 1 lst Comp.2nd Comp Totol Outlet Length 44"175.6" width 61.7" Height 54.5"501 lbs.1006 9ol 50J 9ol 1509 9ol lnlet 47" Wetôr & Wa¡üeurúr ¡ SystemE ¡ Prcducils Frot s956zo4 æooRd3l7 P.O.Bo(æ5 Fu: (7fg) itr}g1n B^sE\ßb'æ81ã-1 Web.lb: rYrwv.udleyprcætæm Eml[ fonüæl@allEpr€æt@mffi PRECASI¡Inc. ¡serulæ Residential Biotube' Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifedme warranty. They prevent large solids from leaving the tank, dramatically improving wastewater qualiq¡ and extending the life of residential drainfields. 4-in. (100-mm) Biotube EfiIuent Fìher 4-in. ( 1 00-mrn) Biotube Jr. (4-in. Biotube cartridge øuail- a[tle sepørateþ as Insert Fiher) 9-in. (200-mm) Base Inlet Fiber 4-in. (100-mm) Insert Fiher t ilt- :, { t ¡ I : ¡ Ii lll Orenco's superior effluentf.lters resist clogging better than all other bmnds. Our stl¿n- d'zrd, futt sized 4-in. (100-mm) Biotube Effluent Filter prouides maximunt. long-term ?rltection in a complete pachage, with housing. Our 4-in. (100-mm) BiotubeJr., at hatf the size of our standard model, has more f.ltering capacity than the full-sized fibers sold. by otber manufacturers. For tønþs utith existing outlet tees, the Biotube Insert Fiber is ideal. Andþr low-profle tanþs, there's the Base Inlet Fiber. * Covere<l by patent numbers 5,492,635 and 4,439,323 To Order Call your neârest Orenco Systems@, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco'com and click on "Distributor Locator." APS-FT-1 Rev.3.4 @ 11/10 0renco Systems@, lnc. Standard Features & Benefits . Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner sat¡sfaction . lnstalls in min- utes inside new or existing tanks; extendible tee handle for easy removal 0ptional Features & Benefits . Alarm available, to signal the need for cleaning ' Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time . Custom and commercial sizes available Easyto clean by simply hosing off whenever the tank needs pumping Removes about two-thirds of sus- pended solids, on average, extending drainfield life Corrosion-proof construction, to ensure long life Lifetime warranty a a a a Biotube Filteting Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes'entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. **-zñ*r € 0rencoSystems'' lncorporatecl Clnnging tfu \Yhy tlte WÌo rld D oes lVa¡ t eu"t ter'i' www.ofenGo.com Nomenclatures ¿l-in. Biotube Filter (standard) lo¿FT Cartridge height: 28" and 36" are standard H0usino he¡ght:36" and 44" are standard Filter diameter (inches) W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = .1/S" filtrationP = 1/1 6" filtration Biotube effluent f¡lter ser¡es f-in. Biotube Filter {base intet modet} --r- I Options: Blank - no optionsM : flow modulation plate installedA = float bracket attached 0pt¡ons:A = float bracket FS = 2" outlet orifice FSO = 2' outlet orifice and 0verflow plate* FTI0S 22-148 Base inlet model Carlridge heiqht: 1 4" standard Housing heighlr 22" standard Filter diameter (ìnches) " Also available with coupl¡ng and sleeve as a "kit": FI-0VERFLOWKIT &in. Biotub€ Jf. (incluoes cartidge and housing) FT J nlo¿ rs tl 08 =8" Blank = 1/8" filtrationP = 1/1 6" filtrat¡on Biotube effluent filter series Blank = 1/S" filtrationP = 1/1 6" f¡ltr'âtion Junior series Biotube effluenl filter series Cartridqe height (inches) Filter diameter (¡nches) P lnsert = 1/8" filtration = 1/l6" filtration no opt¡ons = flow modulation plate installed - float bracket attached -Toooonr, Blank = t\4 A Cartridqe height (inches) Filter diameter (inches) W = f¡ts Type 3034 oullet teeS = fits Schedule 40 outlet tee &in. Biotube Fiher Insert (cartridse only) FT¡f04 ls-I ---T-- I For customized options (e.9,, NC indicales Nodh Carolina reg¡ons) r¡ = fits S = fits Type 3034 oullet tee Schedule 40 outlet tee Blank Biotube effluent filter series Distributed By: tl-in. Biotube Effluent Filter Extendible PVC handle inless steel set screws Top seal plate Air vents Biotube@ filter cartridge Solid base Filter housing ¿l-in. Biotube Jr. Tank wall Riser wall V Double Walled PVG Riser & L¡d Options Poly Lid (Static load tested to 5(100 lbs)o Skid rcsistance surfaceo Available in grcen. Highest level of UV Proþction indudedo lncludes a bam gasket fur airüght and waterd ght applications. lncludes squar€ drive scm,vs b disoourage unauthorized entyo lnsulation panels achieve R-10 insulation raüng 2'ol lnsulation Standald Orenco @ DuraFibern Access Lids (FLD) Not rmmmended fur vehicr¡lar ffic 24'and 3O Diamebßo Solid, resin-infused fiberglass consüuc'tiono 20,00G1b breaking sü€ngüto Standard gr€en or brcwn oolorso Available with or without ureffiane lid gasket. Available with carbm filüation. 4 stainless steel f,athead socket cap scr€uys & hel( key wrendr. lnsulated lids availaHe-T o¡4i Double Walled PVC Riser . Available in 24' and 30' Diametor. Cut to lengür. Sold in +l-2'incremenûs. Must bo cr¡t betu,€en ribg w PREC/ISr, Waüer & Warbwûr ¡ Systems r Ploduds InG. o Senrlæ (zrsl ssoúzot æco'm'317 P.O.Bo(æ5 Fu: flrg) tg5411ín H'unVlda'æ$1z11 Webslb: wrnv.vallryrætæm Eml[ fionüæk@allryrcætæm POLYLOK DISTRTBUTION BOX, RlsERS, AND LID UD€OXO&UD€OXE *-- - 12.451L--D.BOX SEAL (E/BYDÐ(OdCrWm{ 48Eflr) 16'SIDE CUT OUT TOACCEPT POLYLOK SEAL NO.300l TEAROUT FOR 4" SDR-35 0R scHD-40 NOTTOSCAI-E UD.BOX 6'RISER ROTOfLOW4' + 6 t I-Il*-4'-J UD-BOX t2'HSER NOTIOSCAIE POLYLOCK EQUATIZER II.NOTCH'WETR 1 8}IIPEF 8E.F lEì/EJirO R|BSPROì f)EFRtCftOt FfTFMAtl-¡l, PFEID I.TEEEËiTt¡ 20'GOVER FOR RISER & D€OX iror70ff/uE GASKETED SEAL ON LID & RISER ------î \/ Watcr& Wa¡ûewür I SYstems o PrcdudE InG. ¡ Seryloe (z'19) 395€764 2flxFco ru'317 P.O.Bo(æ5 Fu: firg) g#g'nn RHEVISa' æ81211 Webrlb: wrwv.vdlryprcætærn Emal[ fionüeok@dlepecast omffi PRECASI, oQut'Ck4' cHAt40Efr Svsr.t4S IN FI LTRATOR' water technologies The Ouick4'Plus Standard Chamber The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch-wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connection'" which permits turns up to 1S-degrees, right or left. lt is also available in four-foot lengths to provide optimal installation flexibility ïhe Quick4 Plus All-in-One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength Ouick4 Plus" Series Ouick4 PIus Standard Ghamber Benefits: . Two center structural columns offer increased stability and superior strength . Advanced contouring connections . Latching mechanism allows for quick installation . Four-foot chamber lengths are easy to handle and install . Supports wheel loads of 16,000 lbs/axle with 12" of cover Ouick4 Plus All-in-0ne 12 Endcap Benefits: . May be used at the end of chamber row for an inleVoutlet or can be installed mid-trench . Mid{rench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows . Center-feed connection allows for easy installation of serial distribution systems . Pipe connection options include sides, ends or top Ouick4 Plus All-in-0ne Periscope Benefits: . Allows for raised invert installations . 180" directional inletting . 12" raised invert is idealfor serial applications Certified by the lnternational Association of Plumbing and Mechanical Officials (IAPMO) Size 34"Wx53"Lx12"H (864 mm x 1346 mm x 305 mm) Effective Length 48" (1219 mm) Louver Height B" (203 mm) Storage Capacity 47 sat (178 L) lnvert Height 0.6" (15 mm),5.3" (135 mm), 8.0" (203 mm),12.7" (323 mm) Quick4 Plus Standard Ghamber Specifications APPROVED in @ Quick4 PIus''' Series qr4i,F,,f,#i"' Quick4 Plus Standard Ghamber 12', 34',48" EFFECTIVE LENGTH Ouick4 Plus All-in-0ne 12 Endcap PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PTACES) .13" 18" 8" INVERT SIDE VIEW INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY (a) The structural ¡nlegr¡iy of each chamber, endcap and other accessory manufactured by lnfiltrator ('Units"), when installed and operated in a leachfield of an ons¡te septic system in accordance with lnfiltrator's instructions, ¡s waÍranted to the original purchaser ("Holdef) against defective materials and workmanship for one year from ihe date that the sepl¡c permit is issued for the septic syslem containing the Units; provided, however, that if a septic permit is not required by applicable law, the wananty period will begin upon the date that installation of the septic system commences. To exercise its warranty righis, Holder must notify lnfiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifleen (1 5) days of the alleged defect. lnfiltraior will supply replacement Units for Units determined by lnfiltrator to be covered by this Limited Warranty. lnfiltrator's liability spec¡f¡cally excludes ths cost of removd and/or installation of the Units. (b)THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (A) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WTH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PAHTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than lnfiltrator. The Limiled Wananty does not extend to incidental, consequential, special or indirect damages. lnfiltrator shall not be liable for penalties or liquidated damages, ¡nclud¡ng loss of production and prof¡ts, labor and materials, overfìead costs, or other losses or expenses incuned by the Holder or any third party. Specifically excluded from Lim¡ted Wafianty coverage are damage to the Units due to ordinary wear and tear, aheration, accident, misuse, abuse or neglect of lhe Units; the Un¡ts being subiected to vehicle traflic or other condit¡ons which are not perm¡tted by the installation instructions; failure to maintain thê m¡nimum ground covsrs set forth in the ¡nslallation instructions; the placement of improper materials ¡nto the system containing the Units; failure of the Units or the seplìc sysiem due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by lnfiltrator. This Limited Wananty shall be void if the Holder fails to comply w¡th all of thê terms set forth in this Limited Wananty. Further, in no event shall lnf¡ltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulling from installation or shipment, or from any product liability claims of Holder or any third party. For this Umited Warranty to apply, the Units must be installed in accordance with all site conditions requhed by state and local codes; all other applicable laws; and lnf¡ltrator's installat¡on instructions. (d) No representative of lnfiltrator has the adhority to change or extend this Limited Waranty. No wananty appl¡es to any party other ihan the original Holder. The above represents the Standard Limited Wananty offered by lnfiltrator. A limiled number of states and counties have different warranty requirements. Any purchaser of Units should contact lnfiltrator's Corporate Headquarters in Old Saybrook, Connectìcut, prior to such purchase, to obtain a copy of the applicable warranty, and should carêfully read that warranty prior to the purchase of Unils. FRONT VIEW Ouick4 Plus All-in-0ne Per¡scope OUICK4 PLUS ALL-IN-ONE (360'SWTVEt) 12.7" INVERT l5"l I I N FILTRATOR' water technologies 4 Business Park Road P.O. Box 768 Old Saybrook, cT 06475 860-577-7000. Fax 860-577-7001 1-800-221-4436 wì¡vw. i nf ¡ ltratonñrater,com Contour, MicroLeaching, PolyTuff, Chamberspacer, MultiPort, Posilæk, Quickcut, QuickP¡ay, Snaplock and SlEightLock are trademarks of Inf¡llmtor WaterTæhnologies. PolyLok is a tradêmark of Polylok, lnc. TUF-TITE is a registered trademark of TUF-TITE, lNC. Ultra-8ib is a trademark of IPEX lnc. @ 2013 lnf¡ltrator WaterTechnologies, LLC. All r¡ghts reserued. Printed ¡n U.S.A. PLUSos 0713 4\l Contact f nfiltrator Water Technologies' Technical Services Department for assistance at 1-8OO'221'4436