HomeMy WebLinkAboutOWTS ReportMOUNTåIN CROSS ENGINEERINC. INE. Civil and Environmental Consulting ãnd Dês¡gn June 17,2021 Mr. Bruce Barth Red House Architecture 815 Blake Avenue Glenwood Springs, CO 81601 RE: McCarty Residenceo 280 Lariat Lane, Garfield Counfyo CO - OWTS Report Dear Bruce: The purpose of this correspondence is to inform you about the onsite wastewater treatment system (OWTS) designed for the construction of the McCarty Residence. The project proposes to construct a new residence. An existing residence exists on the site with its own OWTS. No modification is proposed to that residence or system. The project is located in Garfield County at 280 Lariat Lane. The main and upper floors of the residence will be a gravity system to a conventional septic tank where a pump will pressure dose to a leach field comprised of a sand filter. The plumbing of the lower level will need a sewer ejector pump to lift into the gravity system. The residence will be served by an existing well. The OWTS is not within a 1O0-year flood plain boundary. There are practical constraints that you should be aware of when considering the proper design, construction, and operation. Subsurface The soil was determined to be R0 soils with an LTAR value approximated as 0.80 gallons per day per square foot (GPD/sq.ft.) based on using secondary sand media and a soil evaluation performed by Kumar and Associates. A profile hole was excavated and an inspection revealed that no bedrock or high groundwater table is within an 8' depth of the leaching area. A copy of the soils report is attached. Design Calculations The residence is proposed to be 5 bedroonrs. Using Garfield County Table 6-l for a 5-bedroom residence, this yields 600 gallons per day (GPD) total. The design calculations for sizing of the septic system and the leach field follow: o McCarty Residence: 5 bedrooms: 600 GPD o Based on soil evaluation and sand media, LTAR: 0.80 GPD/sq.ft. o Minimum absorption area: 600 GPD / 0.80 : 750 sq. ft. o No reductions are allowed for rocky soils. o Required septic tank volume : 1,500 gallons per Garfield County Table 9- I o Dosing frequency : 4 doses per day; dose volume : 600 GPD / 4 doses : 150 gal./dose . Pump(s) should provide 30 gpm at35' of Total Dynamic Head o PVC lateral supply should be Schedule 40, l-l/2" in diameter. o PVC lateral distribution pipes should be Schedule 40, 1" in diameter. o Each lateral pipe should have ten /¿" diameter holes drilled in the lateral aL 6' spacing with the first hole located at 51" from the start of the bed. 826"/zGrand Avenue, Glenwood Springs, CO 81601 P: 970.945.5544 F: 970.945.5558 www.mountaincross-eng.com McCarty Residence June,2021 Page 2 of3 The component manufacturers are typical for the area. Alternatives may be considered by contacting this office. Construction must be in accordance with the speciÏications of Gartield County Environmental Health, the OWTS permit, and this design. Topsoil should be placed over the OWTS and planted with native grasses. No large vegetation and/or plants with taproots should be planted over the absorption area nor grasses that require excessive irrigation. Calculations are attached. Setbacks The location for the septic and dosing tanks are limited by setback requirements per Garfield County and the State of Colorado. These include: o 50' FROM WELL e 50' FROM WATER BODY o l0'FROM WATER SLIPPLY LINE o l0' FROM PROPERTY LINE o l0' FROM LINED POND, DITCH, OR STREAM o l0' FROM CREST OF BANK ¡ 5, FROM BUILDING WITH BASEMENT o 5,FROM LEACH FIELD The leach field setback requirements are o 100'FROM WELL o 50' FROM WATER BODY o 25, FROM WATER SUPPLY LINE o ZS'FROM CREST OF BANK o 20' FROM BUILDING WITH BASEMENT o l0' FROM PROPERTY LINE r 10' FROM LINED POND, DITCH, OR STREAM o 5,FROM SEPTIC TANK The setback requirements deal primarily with buildings and potential contamination from the septic tank, dosittg tank, and leach field to either culinary water or surlace water. These seibauks have been included on the plans for reference. There is an existing waterline that will need to be crossed. The pressurized sewer line will need to be encased for 25' each side of the crossing. Contractor will need to pothole the water lirie to determine its location so that the encasement can be centered on the water line. Operation Information and Maintenance The Owner will need to be responsible for the operation and management of the OWTS. Geo- fabrics or plastics should not be used over the absorption area. No heavy equipment, parking of machinery, or materials should be placed on the absorption area. Livestock should not graze on Mountain Cross Engineering. lnc. Civll and Envlronmental Consulting and Deslgn 826"/zGrand Averfue, Glenwood Springs, CO 81 601 P: 970.945.5544 F: 970.945. 5558 www.mountaincross-eng.com McCarty Residence June,2027 Page 3 of3 the absorption area. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS; for example, running toilets or leaky faucets can discharge hundreds of gallons of water a day and harm the absorption area. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OïVTS. Grease should not be placed in drains and grease traps should be installed upstream of the septic tank but downstream from any kitchen. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. The OWTS is engineered for domestic waste only. The Owner will likely need to contract with a septic system cleaner to clean the septic tank every two years, or as needed gauged by measurement of solids in the tank. The standards of performance for the septic system cleaner are recommended to be the following, at a minimum: l. The Systems Cleaner shall be licensed. 2. The Systems Cleaner, when cleaning a septic tank, shall remove the liquid, sludge, and scum, leaving no more than three (3) inches depth of sewage in a septic tank. 3. The Systems Cleaner shall maintain his equipment so as to ensure that no spillage of sewage will occur during transportation, and that its employees are not subject to undue health hazards. 4. The Systems Cleaner shall dispose of the collected sewage only at a designated site recognized by the Board of Health. Construction Observation Prior to being backfilled, the construction of the OWTS and all of the components will need to be observed by representatives of Mountain Cross Engineering, Inc. The conclusions and opinions that are expressed above are based on the inforrnation available at the time of preparation of this report. Any additional information presented afterward may require that these opinions and the design be modified. Thank you for the opportunity to provide this report. Feel free to call if you have any questions, concerns, or comments. Sincerely, Mountain Cross Engineering, Inc. Chris Hale, PE, Mountain Cross Engineering. lnc. Civil and EnvironmentalConsulting and Design 826 1/, Grand Avenue, Glenwood Springs, CO B'! 601 P: 970.945.5544 F: 970.945.5558 www.mountaincross-eng.com MOUNT¡IIN EROSS ENGINEERING, INE. Oívil and Env¡ronmêñtal Oonlulting and Dcsigrr 8?6 1f? Gr¿nd Avenlle clanwood SÞrtntr, CO 81601 ph S70.9415544 f¡ 970,945.5ı58 M,meunta¡narosHn0.com 5 Bedrooms 600 gallons per day 4 doses perday 150 gallons per dose DOSING DESIGN CALCULATIONS, for 280 Lariat Lane, Garfield County, CO 6t11t20?1 gallons: average day Table 6-1 Step l: Flows Step 2: BODS 75 gpd/person 8 persons 600 gpd used by residence BODS for domestic uses: 0.2 lb/person/day from CDPHE Step 3: Dosing Basin 4 foot diameter manhole depth of dose volume = lnvert in from septic tank SumP = bottom of manhole Pump "Off' Pump On "Lead" Float Pump On "Lag" Float High LevelAlarm 12" from High Level to lnv ln 94.0 gallons per foot of depth 1.ô0 feet of depth in manhole -3.35 -7.92 -6.92 -5.32 -4.82 -4.32 -3.32 5.0 1 2.60 3.10 3.ô0 4.60 minutes of run time per dose = Step 4: Elevations, Orifices, and Head loss Rim Elevation = High Point Elevation = lnvert ln at Manhole = Sump = Elev Diff = 1.4 feet Length of 1-112" = 100 feet Length of 1" = 260 feet 1-112" fittings in equivalent pipe length: check 90 90 check 90 13.44413.44 Equivalent 1-1l2" Length from pump = -0.5 -'1.5 -3.35 -7.92 to Leach field ln Leach field 30 gpm gate tee 1.1 8.1 171.6 feet tee 8.1 tee 8.1 64.2 feel from Fig F, using 8.27 flof friction head per 100'of 1-112" plastic pipe = 14.2 head loss @ 30 gpm from Fig F, using 3.3 ft of friction head per 100' of '1" plastic pipe = 8.6 head loss @ 7.5 gpm Plus operating head at end 5.0 feet Dynamic Head (TDH) 35.2 system condition use TDH of 35 feet Per Table 7-13 in OWTS Design Manual, 114 " dia. orifice @ I'of Head yields 0.75 gpm 4 Laterals 10.0 orifices per lateral 30 gpm Step 5: Velocity verification 30 gpm in 1.5 inch pipe 0.012 = area 0.067 = flow in cfs 5.447 = velocity in feet per second, must be greater than 2.0 feet per second but less than 10 feet per second 7.5 gpm in 1 inch pipe 0.005 = area 0.017 = flow in cfs 3.064 = velocity in feet per second Step 6: Pipe Volume & Drain Back assume only drainback from manifold 1.5 inch pipe 0.012 = cross sectional area 107 .4 = feet in length 1.3'18 = cubic feet 9.96 = gallons 1.26 = inches of drainback into dosing tank