Loading...
HomeMy WebLinkAboutPermitGarfield County Publ c Heo Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 Permit Number SEPT-6929 Permít Type X New X Repair X Remodel/addition X Tank only lssue Date A6125/202I Expiration DateA6/25/2A22 For inspections, call: 970-945-66!4 ext. 8150 and call the Design Engineer, if applicable Project Address: 41 5. Pine Street. Carbondale. CO 81623 Parcel No.: 23932831.30L6 Owner Name: Steven and Bailev Haines Owner Phone: (970) 903-3892 Designer: Sopris Eneineerine, LLC. Designer Phone: ß70\7A4-031.1. Number of Bedrooms 4 Minimum Tank Capacity 1,250 eal Minimum Absorption 612,5 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permít Conditions: This OWTS Permit is approved on the condition of compliance with the application as submitted and plans dated June 23, 2O2t, as well as design changes discussed via telephone WITH Sopris Engineering, LLC. Changes must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve an existing 4-bedroom residence that is currently on the site. The new OWTS will utilize the existing 1,500-gallon tank that is on-site, adding a new 300 to 500-gallon pump chamber set level w¡th risers to br¡ng access to grade with a high-head pump in the new pump chamber to distribute effluent to 650 ftz of STA. The STA will consist of two GeoMat beds 13-feet wide by 25-feet long placed on 6-inches of secondary sand media with four-feet between each bed. Laterals will consist of 1.5-inch diameter Schedule 40 PVC with 5132-inch orifice holes spaced 3-feet on-center (O.C,). lnspection ports are to be installed at each the end of each lateral, as well as the beginning corners of each bed. An impervious liner will be placed in an excavation for the existing septic tank that the installer indicated they would make to better bed the tank on the side of the excavation nearest the STA. Maintain setbacks as indicated above and on the plans. Contact Garfield County Public Èlealth at least 48 hours prbr to request¡ng final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. ln consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void' The issuance of a permit and specifications of terms and conditions there¡n will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system' Permit issuance will not const¡tute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit APProval plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. permission is hereby given to the property owner(s) to perform the work indicated in accordance w¡h the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approvalof the system willbe issued. @;ty'Environmãnta I Health Department 06/2s/2021 Date