Loading...
HomeMy WebLinkAboutCorrespondenceColleen W¡Éh /¿¿¿nf Ua¿l*eaø From: Sent: To: Subject: tawson, brenda <brenda.lawson@judicial.state.co.us> /ø//rl1a L/ g f- Tuesday, luly 27,2021 8:53 AM / ffll"i;,îJiir detached sarasel shop steer projecr lnfu/þr €/aætk Hello Colleen- Chris Whíte forwarded this to me to verify and forward to you. thanks! Brenda Lawson From: Chris White <aasteelinfo@gmail.com> Sent: Tuesday, July 27,202L 8:47 AM To: Rob Lawson <robbrenlawson@gmail.com>; lawson, brenda <brenda.lawson@judicial.state.co.us> Subject: Fwd: detached garage / shop steel project RE: Rob and Brenda Lawson, 1514 Mineota Dr, Silt - permit a ppl ¡catio n BLRE-07 -2L-6977 Message for Owner, Chris White and Alliance Engineering: On behalf of Garfield County, I have started the building and zoníng compliance review for the new detached garage/ steel shop and have a few questíons: 1. ls the proposed building intended for use as a private garage / shop by the owners? And, nof for a place of employment or commercial business operation? With the Rural zone dístrict, I assume the detached garage is accessory to the adjacent private residential use, but ask to confirm with the property owners for the file record. (yeS ) 2. The proposed foundation plan appears to show a shallow foundation / slab design? 2.a Will this be a heated conditíoned buildine? lf so, how will the structure be heated? lnfloor radiant heat tubing? Ceiling mounted unit heaters? Other? (Looking for an 18"-24" mono w¡th foam board if needed.) 2.b Will there be insulation installed to protect the shallow foundation slab from frost heave? (if needed) 2.c. What ís the approximate elevation of the building sitel (51600) 2.d. Will insulation be installed in the exterior walls and/or ceiling system? lf so, provide a detail, 3. Will the detached garage / shop have any plumbing, mechanícal or electrical installed? (NO) ft so, provide a description as this will help us "redline" any comments for elevated protection from spark hazards, vehicle barrier protection and/or other required life safety clearances. 3. lf the building is to unheated and unconditioned cold storage - and the Engineer of Record specifíes the structure is to be below frost per note (see Sheet 3 of 3) - the foundation frost depth must match the site elevation (36 inch minimum). lf however, the owners intends it to be unheated unconditioned building and theír Engíneer of Record specifies the structure is NOt required to be below frost, then we shall ask the Engineer of Record to amend notes on structural plan (sheet 3 of 3) allowing for an unprotected shallow foundation design. (NOn Heated) Questions being brought forth now, to avoid delays and / or changes during actual constructíon. Many thanks in advance for your response, Colleen Wirth Plans Examiner Garfield County Building Divisíon 108 8th Street, Suite 40L Glenwood Springs, CO 81601 cwirthlôsarfí ntv.com office {970) 945-1377 ext. l-610 2