Loading...
HomeMy WebLinkAboutOWTS Design1 r w2.0 N xI PERTY LINE -BEDROOM PROPOSE CABIN SCALE: 1 = 50'=0" 4-BEDROOM ADDITION tr t GARAGE WITH BATHROOM , t SEPTIC TANK TP2 STA , = 55'1 R = 188.71' L = 116.19' C8= N 5658'5f E C - f14.36'- 169.65' - ff5.3C TP1 CB- S 03'43'37' lV C = î15.13' THE LOCATION OF PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVÊY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS'DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENT LOCATIONS ARE ACCURATE. PROPERTY LINES AND SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. SCALED FOR PRINTING ON 11" X 17'PAPER, $ DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 07 I 17 12021 t a. \ 477 CR112 Garfield County, Colorado Project Number: C1631 Thompson Residence Date: 0711212021 Designed by:CBO Drawn by: DD w1 .0 Sheet 1 0F 4 CBO lnc. 129.Cains Lane Carbondale, Colorado 81623 Phone 970.309.5259 carla.ostberg@gmail.com d'" N 4'DIA SDR-35 SEWER PIPE WITH CLEANOUT MIN 2% FALL TO TANK ONE SEWER LINE INTO THE OTHER WITH WYE SCALE: 1" = 20'-0" FITTING I sOO-GALLON, TWO-COMPARTMENT SEPTIC TANK WITH EFFLUENT SCREEN 4" DIA SDR-35 SEWER LINE TO STA (MrN. 1% FALL TO STA) 7 "ô"6" DIA SCH-40 ENCASEMENT PIPE ING STA TO BE ABANDONED BURIED IRRIGATION LINE "e" 4" DIA SDR-35 INSPECTION PORT AT BEGINNING AND END OF EACH TRENCH ' 1i"À -./ 'QUICK-4' CHAMBER TRENCHES. 4 TRENCHES WITH 15 CHAMBERS PER TRENCH FOR A TOTAL OF 60 CHAMBERS AND 720 SF.A: R: t_ CB: ^t¡ 38"57 1 69.65' 115 .3+' DISTRIBUTION BOX WITH ACCESS AT GRADE s 03'+3'37" 11 3.1i' / 4'DIA SDR-35 DISTRIBUTION LINE TO EACH TRENCH (MrN. 1% SLOPE TO TRENCH)PROPOSED OWTS CBO lnc. 129 Cains Lane Carbondale, Colorado 81623 Phone 970.309.5259 carla.ostberg@g mail.com Thompson Residence 477 CR 112 Garfield County, Colorado Project Number: C1631 Date: 0711212021 Designed by: CBO Drawn by: DD w2.0 Sheet 20F 4 15 CHAMBERS PER TRENCH IITIIII ITTIIT III I IIIIIIII INFILTRATOR END PLATE GRAVELLESS 'QUICK4' CHAMBER (4'x 3') 4' DIA SDR-35 DISTRIBUTION LINE TO EACH TRENCH (MrN. 1% SLOPE TO TRENCH) 4" DtA SDR-35 EFFLUENT PIPE FROM SEPTIC TANK 4'DIA SDR-35 INSPECTION PORT DISTRIBUTION BOXWITH 4'max L AT GRADE SOIL PLACED IN 2'min 4',TOP PORT OF CHAMBER END PLATES lLIMIT EXCAVATION SCARIFY GRAVELLESS 'QUICK-4' CHAMBER (4'x 3') rÀ CHAMBER TRENCH SECTION S/ Nor To scÁr.E DIA SDR-35 INSPECTION PORT AT BEGINNING AND END OF EACH TRENCH SMALL VALVE COVER BOX OR IRRIGATION VALVE BOX AT GRADE FINISHED GRADE BOX AND COVER BROUGHT TO GRADE CONCRETE LID ATTACH CAP OR THREADED CLEANOUT ASSEMBLY 24'MtN. FINSHED GRADE COMPACT 4" DIA SDR-35 SEWER LINE (MtN 2olo SLOPE TO TANK, MrN. 1% TO STA)BASE TO SUPPORT BOX 4" PVC PIPE CUT TO FIT -.+ USE HOLE SAWTO CUT THRUTOPOF SCREENED OR SAND FOR BEDD¡NG 3" MtN.BAFFLE OR ANGLED PIPE TO BE USEDEND PLATE 8" MlN.AT INLET TION BOX BOX L BACKFILL OUTLETS oooo CBO lnc. 129 Cains Lane Carbondale, Colorado 81 623 Phone 970.309.5259 carla.ostberg@gmail.com 477 CR112 Garfield County, Colorado Project Number: C1631 Thompson Residence : 0711212021 ned by: CBO by: DD w3.0 Sheet 3 0F 4 OWTS COMPONENTS AND PHYSICAL FEATURES MINIMUM REQUIRED SETBACK APPROXIMATE PROPOSED SETBACK HOUSE TO SEPTIC TANK 5'39' SEPTIC TANK TO WELL 50'139', SEPTIC TANK TO WATER COURSE 50'N/A STA TO HOUSE 20'85' STA TO WELL 100'182' STA TO WATER COURSE 50'N/A DESIGN EDULE 40 END GAP MUST BE GLUED OR SECURED IN AWATERTIGHT FASHION WITH UNDERGROUND SEALANT s-BEDROOM RESIDENCE 75 GPD X 2 PERSONS/BEDROOM X 3 BEDROOMS + 150 GPD (4th ANd sth BEDROOMS) = 600 GPD WASTEWATER FLOW = 600 GPD ENCASEMENT PIPE 40 RIGID END CAP AT EACH END OF PIPE TANK: MIN. 15OO GALLONS HOLE DRILLED IN END CAP MUST ONLY BE LARGE ENOUGH TO ALLOW SEWER LINE TO FIT THROUGH SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAUSF CALCULATED STA = Q/LTAR = 600 / 0.6 = 1000 SF GRAVlry, TRENCHES = 1000 SF X 1.0 = 1000 SF CHAMBERS = 1000 SF X 0.7 = 700 SF I 12SF / CHAMBER = 59 CHAMBERS FOUR GRAVELLESS CHAMBER TRENCHES 15'QUICK4'CHAMBERS IN EACH TRENCH TOTAL 60'QUICK 4' CHAMBERS DIA SDR-35 SEWER LINE. MUST REST ON BOTTOM OF ENCASEMENT PIPE ENCASEMENT DETAIL SOIL PROFILE TEST PIT NO.1 SOIL PROFILE TEST PIT NO.2 -0 DARK BROWN TOPSOIL DARK BROWN TOPSOIL -2 -3 TAN CALCAREOUS CLAY MATRIX TAN CALCAREOUS CLAY MATRIX t-ululIL ;l-ù lrJ -4 SLIP-ON PVC DO NOT GLUE -5 INSULATED TRACERWIRE FINISHED GRADE -6 LEGEND Fl topsoil F,l calcareous clay matrix 4" DIA SEWER LINE -8 NO GROUNDWATER OR BEDROCK ENCOUNTERED DURING EXCAVATION -9 TO TANK TO HOUSE --10 ì ì CBO lnc. 129 Cains Lane Carbondale, Colorado 81 623 Phone 970.309.5259 carla.ostberg@gmail.comI I lÈx¡ Thompson Residence 477 CR112 Garfield County, Colorado Project Number: C1631 Date: 0711212021 Designed by: CBO Drawn by: DD w4.0 Sheet 4 0F 4