HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT
BLRE-08-21 -7 05ó
SCIB LLC
New S/F Dwelling w/ attached garage
59 River Vista, GWS
lron bridge, PH 2, FLG 1 ,2&3, Lor 263
1) ALL WORK SHALL COMply W|TH THE 2015 INTERNATIONAL RESIDENTIAL CODE
(t.R.c.)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED
IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER
REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST,
3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC
BOARD, ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION
ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION &
CERT¡FICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGAÏION
AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE
AND LOCAL FIRE DISTRICT.
s) opEN-HoLE SOTLS REPORT REOUTRED AT FOOTING INSPECTION TO VERIFY 1.50O
PSF SO¡L BEARING CAPACIry. PROVIDE COPY OF ENGINEER'S REPORT FOR
BUILDING INSPECTOR REVIEW AT FOOTING INSPECTION. VERIFY IF APPLICABLE
ANY COMPACTION REPORTS FOR FILL MATERIAL,
ó) A LOT IMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED
SURVEYOR, IS REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE -
INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS -- IS WHOLLY
CONTAINED WITHIN LOT 2ó3 PROPERry BOUNDARIES.
7) pRE-ENctNEERED ROOF TRUSSES, HAVE ENGINEERING FOR INSPECTOR AT TIME
OF FRAME INSPECTION.
S) PER CONDITION OF GRAD-08-21-7057: DRAINAGE SWALE BETWEEN LOT 2ó3
AND LOT 26415 MAINTAINED AS'BOUNDARY LINE'BETWEEN LOT(S)FOR FIRE-
RESISTANCE BETWEEEN STRUCTURES,