HomeMy WebLinkAboutCorrespondence Regarding Plan Review Correction NoticesBUILDING DEPARTMENT 708 E¡ghth Street, Suite 407, Glenwood Springs, CO 87607 Tel: (970) 945-8212 5T+ hn4Lrtrà fup57vø4 PLAN REVIEW CORRECTION NOTICE TT"I4 Garfield County CBUILDING PERMIT NO: OWNER: PROJECT DESCRIPÏION: DATE: ISSUED BY: BLCO-11-20-6588 Aspen Polo Partners, LLP Equestrian Pavilion + Observation Deck December 3L,2020 Dave Argo - Plans Examiner fr..: /o-13-ts) / Plans submitted to our office are incomplete and include several outstanding issues which must be first addressed before we can continue our plan review and issue building permits, including the following: (L) Buildine Footprint Outside of Platted Buildins Envelope - As illustrated on the Site Plan the building footprint (covered porch + roof above) encroach beyond the Building Envelope by approximately five feet on east side - see attached redlines. Encroachments beyond the extents of the Bu¡ld¡ng Envelope are not allowed as per Garfield County's Land Use & Development Code. All building structural elements must be fully contained within the Building Envelope. Please revise and resubmit the Site Plan to comply with these requirements. (2) Restroom Lavouts Not Compliant with Accessibilitv Requirements - As shown on Main Level Floor Plan (Sheet 1) plans do not comply with LB.C. Chapter 1L & ICC/ANSI-2009 Accessibility Standards. Restroom layout plans also do not match up with Plumbing/Mechanical Plans included in submitted drawings (Sheets M-1- and M-2). Revise Architectural and Plumbing/Mechanical plans to match each other and to comply with ADA/accessibility requirements. (3) Plumbine Fixture Count - Total occupancy of this building = l-62 people (including covered patio areas) and this occupancy count requires a minimum of (3) WC in each of the restrooms (see Table 2902.1l'Also, provide drinking fountain and service sink. (4) Commercial Kitchen - Kitchen & food prep areas shown on the main level constitute a commercial kitchen and this must be permitted and approved through Garfield County's Public Health Dept. Please contact Nettie Mojarro to discuss application requirements and approval process. (5) Means of Eeress from Upper Level Observation Deck - Upper Level Floor Plan items to be revised include the following: A. Number of Exíts - Two Exits are required from upper level Observation Deck (not one as' currently shown on plans). Total No. Occupants = 450 S.t./7 = 65 people (see Table 1006.2.1) Provide a second means of egress from upper level. Amend plans and resubmit. B. Stair Landing - Upper level stair landing does not comply with Section 1011 as door in open position reduces landing depth by more than half of stairway width. Revise stairway layout, provide dimensions & details at stairway/landing and resubmit. (6) Wood-Burnine Fireplace - This wood-burning fireplace may not be allowed per PUD requirements. lf allowed by the PUD, it shall comply with Colorado State Statutes for wood-burning devices (EPA - Phase 3 standa rds/requirements). (7) Architectural Sheet 3 - Not included in submitted set of plans. (8) Roof Plan - Not submitted as required. (9) Buildine/wall sections, construction details, and/or insulation specifications - Not submitted as required. Clearly illustrate insulated thermal envelope and insulation values complying with 2009 l.E,C.C. Provide wood to concrete waterproofing details as referenced on Structural detail notes. 8.12'PONDEROSA :D BY CONDITION OF oF THE 2020 MCCLURE ) AMENDMENT EXISTING VÊGETATION YAND HYDRANT DRAIN DRÀIN YARO IIYDRANT [x, lRn vALVF 80x çX, IRß VALVË BOX ASPEN CO 8161"1 tonstruntion llotss {Contractor to verifY all 1) Constructed lmPro a) Horse Paddocksl Shall be 16" from ground to bottom I exercise track and Horse Pat b) Horse Washes: Shall have pavers w¡th center drain to ( connected to overhead rota c) Fencing & Gates: Fences: height steel ranch gates, dar d) Flagstone Patios & Walkt¡ 6" risers and 16" treads inclt e) Horse Paths: Shall be san lrrigation Verify clock locâtion, Po\ Drip or bubbler{YPe irrig c) Spray irrigation is require not be spray irrigated, d) Spray heads located with fences) to protect from dan e) lrrigation shall be Providr components shall be comPi f) All drip ¡rrigat¡on shall usr Rain Bird Xeri-Bug i (1) Per Perennial (2) PerShrub (3"4) Per Deciduou g) Contractor shall Provide 3) Topsoil and Soil I a) Contractor shall remove and/or amendments. b) Topsoil shall be Placed ir c) Topsoil shall be Placed ir installing sod, d) All planting beds and tut specified by the manufactt e) All planting beds shall bt hardwood mulch. Mulch r 4) Revegetation a) lnstall sod in areas Per P b) lnstall seed mix in areas c) A viable seedbed shall b d) Seed shall be broadcast e) All seeded areas shall br g) SEEÞ MIX: Rivendell 25% Blue 20% Blue 15% ldahr IlYo Arizc I0% AlPir 10% lndia 5% Sandt 2r/z% Bott 21'/to/u ?rai Source: Rivendell Distribu --,{ts-ú--" )rg,W'-: ì ':! .l-l -PAODOC(PADDOCK 3 HORSE HORSE r: cRr,si[ ¡tNÊ5 foR 6ATÉ PAfH t_ +h o l{¡ t{ o oa- HONSE PA-fH B0x IRR Vg ]AND {TYP.) "-*- HoRSE\- PATH 0 o gA i PÀOOOCK 2 Ç PAÓDOC(t Ç PÀÞDOCI( 6 "É,- ) ORSE + +++ + + +-f+ +++ + + + + ++ + l" I 1È t- *E=' :Êl ++ ++++ ++ +++ +++ên¡sb +a++ +o: -å ++ + + + + {r==-, ++ l- + ++t + .l + + + + + t. PAVILLION 4 i iì.CONY ENCROACIIMENl ÂLLOWED PTR PUÛ GUIOE SecTroN 5.2 + + + +{. + HORSE tarE MtN. 10' 5€PARATION IIEQ. PTR PUÐ GUIDË s€0toN:t.x.1 .u*::J PADDOCK 1.l {. ,f If ++ t. + t ++l. + .I + + l,-o: + t¡¡rts. n . "+++fl_+l .|++++t .:\ ô PAOOOCKIôPAOll0cRIÕPAÞDÙCRItIPAODÔCK 11PADOOCN 12 *la{ 6',CONC, B^NO (rYp ) IX. IRR VALVE OOX ûtMìFFiz$-l \T'sI-*s-t\êñ=J I xsIiI',.1¿-. I''T lIl l I J, .ì ,ìii 715 rrl t-': îq Kj> +{ .l-- Nl TL \-+. ¡r. 6: til l-i- ji f+- * l+- - \A/AR.Þ ancJ ASS()CTATES, ll{C,arcl-¡ itecture F nd trDlan'ni ng z8olzo'atrcêt, Souldet' cotorador 8oto4 Ë¡.3c,9.442.1?01 Job Þat, Rev '-7 M -rl¿tr*^ãlå l-lLn a-t'IIt--',tr"- - -'I4.{z+Å¿àù'q'.àt*¿ #4.i":iJ,v-$6\II$lË Garfi elcl County Building Departnrent RE: permit no. BL.CO-11-20-6588 lJquestrian Pavilion and Observation Deck The following are responses and corrections 1- îlq PUD has been clariñed/amended to allow lbl tlie liont porch ro exrend into the past the building envclope 2- The restrooms have been redesigned to Accessibility standards. The Mechanical plans have been revised to match the Architectural plans 3. Plurnbing fixture count...on page 5 *r, o""rpuncy load calculation has been prepared. It' demonstrates a total of 118 occupants, which will be 59 men and 59 *o**rr. f'tt* tixtur."* provide are in accordance with minimum fixttue required per 2902.3., also attache¿ on sheet 54. The prior kitchen design has been eliminatecl anct a simple wet bar iu no* shown in lieu of.5. a' IÌxits required. Sheet 5 shows arì uppcr level occupancy diagram for 380 nct Sq Ft. This equates to 25'3 oæupants fÌlr this level. Per tabfe 1015.1 there is not a requirement for a second exit ur*il there are 49 occupants. b' The stair landing at the top of the stairs has been rev,isecl so that the cloor does not encroach on the leuicling 6. Thc exterior woocl liurrring fireplace has been deletecl and replace with a gas fireplace.7. Sheet 3 is now included in the set 8. Ärchitectural sheet 3 is now included 9. A rool'plal has been preparecl, See sheet 4 l0- Sheet 3 specifies all thermal envelope requi¡ements ancl values. A note has been added to address watet?roofing of wood to concrete as r:eferenced on the structural notes at details 2/s3,l and 3/s2.1 Tha¡ìk you fbr your review and consideration, lVlark Ward Architect 20ol zoltt $TREET Booldêr, tolorado, SO3O4 í,Xí.4a242ç,¡