HomeMy WebLinkAboutCorrespondence Regarding SidingJim Wilson From: Sent: To: Subject: Jose Gonzalez <jose@jcaliberconstruction.com> Tuesday, October 19,2021 9:49 AM Andy Schwaller;Jim Wilson; Paige Haderlie lExternall Flashing To all, This email is to address the lack of flashing on the siding, regarding 690 Cattle Drive Silt, CO. We did not use flashing according to code, because the home owner felt it would greatly impact the architectural appearance of the home. JCC took extra precautions in this case to ensure materials would not be compromised. We used board and batten style siding. This consist of 4X8 sheets of rough sawn wood siding. We (JCC) used a solid stain on exterior, to ensure water proofing and protection of the siding, we applied two coats of solid stain to the back of each sheet. ln addition we caulked behind every seam to keep moisture from working its way behind the seams. We finished the front side by again caulking the seams and stapling the material every l-2" and then again when the battens were laid on top of 4X8 sheets. We applied 3 coats of solid stain to the exterior of siding. We understand that not using flashing voided the Manufacturer warranty on the siding material itself. Which only one year. JCC however is very confident in the precautions taken to waterproof and seal the siding, because of this JCC will warranty the siding for the home owners Paige and Zane Haderlie for the next 5 years. As long as the exterior stain is maintained properly. Regards, Jose Gonzalez J Caliber Construction (970) 314-0489 1 Jim Wilson From: Sent: To: Cc: Subject: Attachments: Andy Schwaller Thursday, April 15,2021 3:24 PM Matt Provost Jim Wilson; Colleen Wirth J Caliper-- LP SmartSide Siding 0972-001.pdf Josecalledandsaidtheownerdidnotwantthehorizontal buttjointflashingduetothelooks. Thesuppliersaidit voided the warranty not to have the flashing at the horizontaljoints. Jose is going to get a letter describing how they "waterproofed" the butt joint and a letter from the owner wanting the butt joint without the flashing. lf one looks at the application instructions and code, it appears the flashing should be in place. Also with multi-level structures, a "beltline horizontal joint" is required as an expansion joint incase the framing under the siding shrinks. lt is 2- 3/8-inch gap with flashing and a horizontal baton w¡th flash¡ng to cover the filler board behind and provide an overlap for the next piece of siding. Note the framing behind the expansion joint with the attached. I doubt we ever get that in the field. See attached info. This may have been the issues with more than a few other projects where they used the panel style siding and we should discuss once we are all back in the office. Thanks, Andy 1 APPLICATION INSTRUCTIONS LP TRIM & SIDING . At the tlme of manufacture, siding meets or exceeds the performance standards set forth in ICC-ES 4C321 and has achieved code recognition under E5R-l301' CCMC 11825-L' APA recognition under PR-N124, and HU0 recognition under HUD-MRf 1318t, For copies of Product Approvals go online at http:: //lpcorp,com/resources/product-litetatute/ or call LP Customer Support at 800-548-6893. . Strand Substrate panel sidlng with SilverTech or SmartFlnlsh is specifically for sheds and other outdoor 5tructures where the interior wall cavities will remain permanently exposed, . Minimum 6 inch clearance must be maintained between siding and finish grade (ground cover). . Slding applled adjacent to porthes, patios, walks, etc. must have a clearance of at least 1 inch above any surface. . Minimum 1 inch clearance at ¡ntersection with roof line . Applysidingin a mannetthat prevents moisture intrusion and weter buildup. . All wood substtate that ls exposed to the weether must be sealed in a manner that prevents moisture intrusion and water build up,- Seal ALL exposed cuts of siding and trim. Field spray applied coatings on cuts are not recommended. - Sealing can be accomplished by applying a coating or sealant according to the manufacturer's requirements' . All exposed wood subst¡ate must be sealed in a menner that prevents moisture intrusion and water buildup, . LP does not recommend LP SmartSide Panel for use in ICF assemblies, lf used, LPwill notwa¡rant for Buckling and Shrinkage. However, balance of warranty does remain intact, . Use nails to fasten LP SmartSide panel siding to structurel framing, The use of alternate fasteners such as staples is permissible only when allowed by l-Codes and where the size, embedment, placement, and number of alternate fasteners is designed by a licensed design professional and approved by local building offitial. The use of alterneté fasteners, however, is not recommended and LP will not warrant any damage ot performance failures to the extent caused by using any alternete fastenets. . SIDING MUST NOT BE IN I]ÍRECT CONTACT WITH MASONRY CONCRETE, BRICK, STONE, STUCCO OR MORTAR. . Store offthe ground well supported, on a flat surface, under a roof or separate waterproof covering . l(eep siding clean and dry. lnspect prior to application' STRAND SUBSTRATE 38,75 AND 190 SERIES PR,IMED PANEL 5ID¡NG INCLUDINC SILVERTECH Ê SIIARTFINISH Strand 5ubstrate 38 and 75 Series panel siding must be installed with the long dimension vertially on studs spaced max. 15 inch o.c. When installing on 24 inch o,c. framing' 190 Series panel siding is reguired, . Mo¡sture conttol and watervapor control are critical elements of proper housing design. Check your local building codes fot application procedures for handling moisture end watervapor in your area. . When using wet blown cellulose insulation, the insulation must not be in di¡ect contact with the siding and it must be allowed to dry a minimum of 24 hours or longer if specified by the ¡nsulation m anufa[turer. . As with all wood products, do not apply engineered wood slding to a structure having excessive moisture conditions such as drying concrete, plaster or wet blown cellulose insulation. lf such conditions ex¡5t, the building should be well ventilated to allow it to dry prlor to the applicatlon of the siding. . Siding must not be applied to green ot ctooked structural framing members. Do not apply siding over rain-soaked or buckled sheathing materials. . Gutters are recommended for control of roof water run off. . LP strongly recommends the use of a secondarywater-res¡stive barrier behind all LP 5martSide sidlng' A properly installed WRB provides a second line of defense to incident¡l moisture behind the siding. . The LP SmartSide limited warranty does not expressly or implicitly cover water penetration, LP does not assume responsibility for any water penetration. . Sheds and other accessory structures that are not heated or cooled do not requ¡re a secondaty WRB if exempt by applicable building codes, , Seal all gaps with a high-quality, non-hardening, paintable sealant. Follow the sealant manufacturer's instructions for application. ' Use an exterior-quality, non-hardening, paintable sealant. Use Class 25 or higher exterior sealant meeting the ASTM C920 Standard for Specification for Elastomeric Joint Sealants' Follow the seelant manufacturer's instructions for application, SmartSide' 1 GeNeRnL Sruo Spncltuc MoISTUR E Seco¡¡oanv Ware n-ReslsrlvE BnnRleR (WRB) Gnps ç Senla¡¡rs SroRacr Applicatlon instructlons (cont.l . Shear values for panels applied directly to studs shall be no greater than noted in Table 1 of the ICC-ES Report ESR-1301 or Table 1 ofAPA PR-N124. . Not w¡rrantrd for rppllcrtlon on ICF ¡sscmblhs. . 38 and 75 Series panels must be installed on 15 inch o'c, framing only, When installing on 24 inch o.c. framing, 190 Series panels are required. . Backside of panel must not come in contact with masonry or concrete foundation, . Do not force siding into place, Maintain the illustreted 118 inch gap behind the ioint to allow for expansion while the panel equilibrates with the local envlronment, . DO NOT INSTALL OVER ALIGNMENT BEAD' lnstall panels in light contact to the edge of alignment bead' (see Figure 1 and Figure 2) . Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. . Where siding butts window trim, door casings and masonry, etc' leeve a l/15 inch gap and seal, ln¡ul¡ted Sheathingr LP SmartSide Sidings may be installed over low-compression rigid foam or exterior gypsum. The following ptecautions must be followedr a) Adequate bracing of the wall in accordance with the lnternational Codes or other ruling building code is required' b) For rigid foam sheathing uP to 1 inch (25 mm) thicl(' siding may be nailed directly to the foam sheathing unless a drainage plane is required by the local building code. Nail length must be increased to ensure a minimum 1'ir12inch (38 mm) fastener penetration into the structurel framing. c) For rigid foam sheathing greater than 1 inch (25 mm), a minmum 1-l12inch(38 mm) thick bV 3-112 inch (89 mm) wide vertical strapping or furring strip must be installed over the sheathing to provide a solid, level nailing base forthe siding' The strapping must be securely fastened to structural framing spaced no greater than 15 inches o.c. (406 mm) with a minimum nail penetrationatl-112 inches (38 mm) and a maximum nail spacing no greater than the width of the siding, Louisiana-Patific Corporation will assume no responsibilityfor any damage ot condition arising from the use of rigld foam or exterior gyPsum. 'l2" max. field nailing 1"n, clearance from roofing Figure 4 HORIZONTAL WALL l0|NTS BUTT Ë FLASH idlng ng 1" min. overlap Figure 5A LAPPEO l{ORl ZONTAL WALL l0lNT 5lding truss 1" min. overlap COilDITION 5nug Flush Visible fiber Eountersunk r/16" -t 18" - Countersunlt mofe '- then r/8" 4" min. vertlcal flashing 3/8" min. gap CORRECTION 0l( or( Peint Apply sealant Apply realant and -re-nall LAP Siding ovef Prime and paint bottom drip' edges panel Figure 5B 6" max. perimeter nailing 6" max, perimeter nailing 6" min, ground clear¡nceDo not let panel contãct masonry 3 1 IN. ROOF Ê CHIMNEY CUENPNTUCE LP SunnrSrDE PANEL 5lo¡rvc f otrur Dernlls Figure 3 (see Figure 7A and 78) Figure 5C Wall Framing c' Figure 104 Shlptrp Edgr Prnrl panel Jolnt alternate inside corner details Vapor Retarder ll l¡aulred trv iodo Water-Re Barri Figure 108 sistive er 6 ln. F¡gure 10 bottom course detail ' 6 in. minlmum û pshl ground cleafance Figure 10C t I l', i Gap 3/16" and seal Gap 3/16" and seal I tigure 10E 5 Figure 10D LpzB0517 04/09/2020