Loading...
HomeMy WebLinkAboutPermit CardGarfield Coanty Pu c Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 Permit Number SEPT-6994 Permit Type X New X Repair X Remodel/addition X Tank only lssue Date o8/L1/202t Expiration Darc a811112o22 For inspections, call: 970-945-66L4 ext. 8150 and call the Design Engineer, if applicable Project Address: 1491 Huebinger Dr, Glenwood Sprinss, CO 81601 Parcel No.: 239502206050 Owner Name: Risoberto Hernandez Owner Phone: {970}618-9637 Designed By: CBO Septic Consultins, lnc. Designer Phone: (970) 309-5259 Contractor: Valenz Construction Contractor Phone: {970) 456-6483 Number of Bedrooms: 4 Mínimum Tank Capacity: 1.250-eallon Minimum Absorption: 735ftz OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Conditions This OWTS Permit is approved on the condition of compliance with the report and design as submitted by CBO Septic Consult¡ng, lnc. dated June 29,2021". Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new four-bedroom residence. The system will consist of a new, two- compartment L,500-gallon sept¡c tank set level with access to grade and an effluent filter in the outlet tee of the tank. Effluent will gravíty flow to a distribution box set level with access to grade that will distribute effluent to 768 ft2 of STA. The new STA will consíst of four gravelless chamber trenches, each trench consisting of 16 chambers per trench (64 chambers total). lnspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final ínspection of the installed system pr¡or to backfill. Agreement All installations must comply w¡th all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. ln consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liabilitç nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operat¡on will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit ApProval Plans and specificatíons for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval ofthe m will be issued. 08/n/2a2L Datelssued By: Garfield County Environmental kealth Department