Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 7315 County Road 312, New Castle, CO 81642_ Parcel No.: _218332200011
Owner Name: Matthew Ringer Owner Phone: (970) 618-5993
Designed By: CBO, Inc. Designer Phone: (970) 309-5259
Contractor: Future Company West Contractor Phone: (970) 987-1551
Number of Bedrooms: _4_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 1050 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7215_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _11/15/2021____________________ Expiration Date_11/15/2022_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated October 16, 2021. Changes to the design and permit must be approved
by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new four-bedroom residence. The system will consist of a new, two-
compartment 1,250-gallon septic tank set level with access to grade. Effluent will gravity flow to a
distribution box and then to six trenches, each 58.5-feet in length that will distribute effluent to
1,053 ft2 of STA. Each trench will be 36-inches wide and a minimum of 6-inches of sand filter
material. The new STA will consist of a total of 351 linear feet of 39-inch wide GeoMatâ„¢ including
geotextile fabric. Distribution laterals will be placed on GeoMatâ„¢ distribution mats placed directly
on the sand. Distribution laterals are to be 4-inch diameter perforated distribution pipe. Inspection
ports are to be installed at the beginning and end of each trench. Maintain all setbacks and
elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
11/15/2021
Issued By: Garfield County Environmental Health
Department
Date