Loading...
HomeMy WebLinkAboutConditions of PermitcoN DITIO NSO F PERMIT B LR E-10-21 -7 224 Michael & Barbara Gerber New S/F Dwelling w/ attached garage 170 M¡dland LooP, Carbondale Aspen Glen, FLG 3, Lot WP9 1) ALL WORK SHALL COMply wtTH THE 2015 INTERNATIONAL RESIDENTIAL CODE (t.R.c,)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l'E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS", NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNc AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WtLDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT, s) opEN-HoLE sotls REpoRT REOUTRED Ar FoorlNG INSPECTIoN ro v_Ellry sooo/zrø PsF SOIL BEARING CAPACITY. PROVIDE COPY OF ENGINEER'S REPORT FOR I ' BUILDINGINSPECTORREVIEWATFooTINGINSPECTION' ó) pRE-ENctNEERED ROOF TRUSSES, HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME INSPECTION. 7) A LOT IMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED SURVEYOR, IS REQUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE - INCLUDING OVERHANGS, DECK AND ROOF PROJECTIONS -- IS IN COMPLIANCE WITH MINIMUM SETBACKS AND/OR BUILDING ENVELOPE REOUIREMENTS. 8) AN ELEVATION SURVEY, SEALED BY A COLORADO LICENSED SURVEYOR, IS REOUIRED AT FRAMING INSPECTION TO VERIFY ACTUAL BUILDING HEIGHT,