HomeMy WebLinkAboutPermit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: _TBD Scutter Lane_____________ Parcel No.: _212728400389 Owner Name: Samuel Jurmu Owner Phone: (970) 987-0195 Designed By: CBO, Inc. Designer Phone: (970) 309-5259 Number of Bedrooms: _5_ Minimum Tank Capacity: 1,500-gallon Minimum Absorption: 1,440 ft 2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-7247_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _12/07/2021____________________ Expiration Date_12/07/2022_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by CBO, Inc. dated October 22, 2021. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new five-bedroom residence. The system will consist of a new, two- compartment 1,500-gallon septic tank set level with access to grade. Effluent will gravity flow to a distribution box and then to two beds that will distribute effluent to 1,440 ft2 of STA. Each bed will be 72-feet in length and 10-feet in width with a minimum of 6-inches of secondary sand filter material. The new STA will consist of a total of 432 linear feet of 39-inch wide GeoMatâ„¢, placed directly on sand, including geotextile fabric. Distribution laterals are to be 4-inch perforated distribution pipe, placed down the center of the GeoMatâ„¢ under the top layer of geotextile fabric. Inspection ports are to be installed at the front corners of each bed and at the end of each lateral. Maintain all setbacks and elevations as designed. Inspection ports are to be installed at the front corners of each bed and at the end of each lateral. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 12/07/2021 Issued By: Garfield County Environmental Health Department Date