HomeMy WebLinkAboutISDS Inspection 05.05.2021Down Valley Sept¡c & Drain, lnc. PO Box L967 Rifle, CO 81650 (e70)e30-0 r24 ISDS INSPECTION CUSTOMER NAME: BLAKE & ALISSA PILAND DATE: MAY 5,242L ADDRESS: 113 FOX RUN ROAD, RIFLE CO CLEANOUTS: YES, WEST SIDE OF HOUSE lN SIDEWALK TYPE OF TANK: 1000 GALLON CONCRETE TANK LOCATON OF TANK: 35' WEST OF CLEANOUT CONDITION OF TANK: GOOD, LIQUID SIDE OF TANK SETTLED CAUSING OUTLETTO BREAK # OF LIDS: 2 DEPTH OF LIDS: SURFACE CONDITION OF LIDS: GOOD # OF RISERS: NONE INLETT: OK OUTLET T: TWISTED DUE TO TANK SETTLED OUTLET FILTER: NONE BAFFLES: YES, GOOD LEACHFIELD LOCATION: WEST OF TANK LEACHFIELD TYPE: INFILTRATORS LEACHFIELD VENTS: NONE LEACHFIELD LOAD TEST: WAS NOT ABLE TO GET VOLUME OF WATER NEEDED TO REALLY TEST LEACHFIELD WORKINGI YES, BUT NEEDS HYDRO JETTED RECOMMENDATIONS: OUTLET NEEDS REPAIRED AND PVC T'S REPLACED OVER ALL cONDITION OF SYSTEM lS FAIR ***PLEASEBEAWARE: DownValleySeptic&Drainacceptsnoresponsibilityfortheproperoperationofth¡ssepticsystem. Thesystemisthe property of the homeowner who is responsible for the maintenance and operation of this system. This inspection does not constitute a guarantee nor is any warranty expressed or implied thdt the system will function properly in the future. Down Valley Septic can only make observation based on the condition of the septic system at the time of the inspection and will make no prediction on the future functionality of any part of the septic system.