Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-12-21-7 266 SGJ D, LLC Private Use Equipment Barn Only (includes no framed loft space) 1708 CR 121, GWS s.32, T.0ó, R.87, 218932200033 NOTICE ON WORK SCOPE: This structure has been reviewed as a private use, equípment barn only. Future changes in building use and/or constructing habitable living space(s) within the existing framed footprint, shall first require submission of a new building permit and plans for review to verify compliance with building codes and land use regulatíons ín effect at time of future work. Any change in land use or creation of another dwellíng unit may require a separate land use application & approval process. 1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATIONAL BUILDING CODE (r.B,c.)AND 2009 TNTERNATIONAL ENERGY CONSERVATION CODE (l,E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST, 3) ELECTRTCAL PERMtTTtNG AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY, 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. \sæ over conàihms + 5-8 5) OPEN-HOLE SOTLS AND COMPACTTON REPORT REQUTRED AT FOOTING INSPECTION TO VER¡FY 1.50O PSF SOII BEARING CAPACITY. PROVIDE COPY OF ENGINEER'S REPORT FOR BUILDING INSPECTOR REVIEW AT FOOTING INSPECTION. ó) ENGINEERED SEPTIC SYSTEM: ON.SITE WASTEWATER TREATMENT SYSTEM (OWTS)TO BE INSPECTED BY PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. PROVIDE ENGINEER'S FINAL REPORT PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 7) NO FUTURE BATHROOM PLUMB|NG F|XTURES ARE SHOWN ON THE RECEIVED DRAWINGS, FUTURE UNDERGROUND DWV OR WATER PIPING -- IF ANY PROPOSED FOR INSTALLATION UNDER SLAB -- SHALL BE PRESSURE TESTED PURSUANT TO CURRENT ADOPTED PLUMBING CODE AND SAFELY STUBBED OUT / CAPPED OFF before FRAMING INSPECTION. 8) SHEET 51 AND CONTRACTOR OF RECORD IND|CATE THIS BUILD|NG STRUCTURE WILL BE SERVED BY A FIRE SUPPRESSION SYSTEM, GENERAL CONTRACTOR OR THE SELECTED FIRE SPRINKLER INSTALLER SHALL CONTACT CARBONDALE & RURAL F|RE PROTECTTON D|STR|CT (BtLL GAVETTE) TO OBTATN FrRE SPRTNKLER PERMTTS AND ROUGH-tN / FTNAL TNSPECTTON APPROVALS. CONTACT (970)963- 2491 OR oavette@carbondal efire.oro.