HomeMy WebLinkAboutPermit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 152 Rusty Spur Trail, Rifle, CO 81650 Parcel No.: _212733100375
Owner Name: Humberto Murillo Owner Phone: (970) 379-1357
Designed By: Kumar and Associates Designer Phone: (970) 945-9788
Number of Bedrooms: 5 Minimum Tank Capacity: 1,500-gallon Minimum Absorption: 700 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7302_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _01/19/2022____________________ Expiration Date_01/19/2023_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by Kumar and Associates dated November 29, 2022. Changes to the design and permit
must be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new 3-bedroom residence, with future plans to expand the residence by
2-bedrooms. The system will consist of a new, two-compartment minimum 1,500-gallon septic tank
set level with access to grade and an effluent filter shall be installed in the outlet tee of the tank.
Effluent will gravity flow to a distribution box set level with access to grade that will distribute
effluent to 720 ft2 of STA. Due to shallow bedrock encountered in pit 2, an additional profile pit
should be excavated at the time of construction near the eastern end of the STA to verify the
required 4-feet of soil separation from the bottom of the trenches to the bedrock surface. The new
STA will consist of three gravelless chamber trenches, with each trench consisting of 20 Infiltrator
Quick4 chambers (60 chambers total). Inspection ports will be installed at each end of each trench.
Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
01/19/2022
Issued By: Garfield County Environmental Health
Department
Date