HomeMy WebLinkAboutFoundation Design ParametersRECEIVED JAN 2 0 ?02? GARFIELD COUNTY GOMÙIUN¡TY DEVËLOPMENT CAPSTONE E'V.rERPRTSES WEST,ü_il_c GEOTECHNICAL AND MINING ENGINEERITì¡G TESTTNG AND INSPECTTON SERVICES óI8 PARTEE DR¡VE 6RAND JUNCIION. CO 8150¿. PHONE (970) 250-5351 June 16,2021 JOB # 4573 Attn J Caliber Construction Rifle, CO Subject: Foundation Design Parameters This letter is to clarify the design parameters used for the foundation design for your residence in the Antlers Ranch SuOO¡vis¡on. The elevation at the site of the residence is approximately 5,715 feet above sea level. Requiring the residence to be designed for a 40 psf snow load and a 36 inch frost depth. For the foundation design, the truss loads were taken from the truss drawings supplied by TRUSSFAB. The truss drawings state that the loads were calculated based on 40 psf snow load a maximum wind speed of 115 mph in accordance with 2015 lnternational Building Code. The notes on the architectural plans should be disregarded. The foundation bearing capacity was limit to 1,250 psf, per the recommendations of the geotechnical repoñ preþared by Capstone Enterprises West, LLC (Capstone) in June of 2020' A f-rost depth of 36 incñes was iniorporated into the foundation details. Once again the notes on the architectural plans should be disregarded. Capstone betieves this foundation design complies with the requirements of Garfield County. Respectfully Submitted : CAPSTONE ENTERPRISES WEST, LLC Martin W. Chenoweth, PE Registered Professional Engineer 781 çf¿t MWC