HomeMy WebLinkAboutOWTS Equipment SpecsItem #
lM {o60-2GP
1060 Gallon Ttno GomPartment
lnflltratol@ PolY Tank
2¡l'AOCESSOPEI{II{G\
IT Top
Mew
TANKTOP
HALF
coNTtNUOUS
GASKET
TAÀIK
INTERIOR SEAM CLIP
(61)
*.7
Ð,ÍERIOR
HEIGI{T
&uE
I
1T
ilT
I
Sec.tion
TA¡IK BOTTC¡M
}IAIF
Mid-Height Seam
Section
Tmklndudæ 116
ALIGNMENT
DOWEL(ír4'
OUTLET
Mew
Æ
ET
o Compliont with CSA ond IAPMO Stondords
e PVC risers ovoilobleo Secondory sofety screen ovailoble with PVC riser
r Moximum buriol dePth ís 48"
r Minumum buriol dePth is 6"
o Tonk is not roted for vehiculor troffic loodíng
¡ Exterior of monhole cover includes the following
worning: "DANGER Do NoT ENTER: PolsoN
GASES"
SEAÂil CLIP
(rYPICAL}
LIFTING STRAP
(fYPrc¡r-)
End
View
Digging Specs
2' Long x 7' Wide lnlet ,Outlet
47" l, +4"
Dímensíons
Length: Width
127" :62.2"
Height¡
54.7"',1094 qot
ffir,rrnf¡gn'
¡ttâtClllË¡r,C.
:1
ln vert Net
itvoc
tWeigh
stb320
cop
t,
Bdlûsl
WÍü&
Wütcuilcr
¡SystorlE
¡ Prcduds
gre)les{zc4 ffipotz
Fæ Olg) tff.¡¡ïn BHE\ßb'@81ã1
W¡b¡lb: wrrw.wllqpmcast øn
Emd[M¡InG.oserulce
Residential Biotube' Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Fifters, and Biotube Base Inlet Filters a¡e ideal for residential septic
tanks and have a lifetime warranry. They prevent large solids from leaving
the tank, dramatically improving wasrewarer qualiry and extending the life
of residential drainfields.
4-in. (100-mm) Biotube Effluent Fiber
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartidge aaail-
able separateþ as Insert Filter)
B-in. (200-mm)
Base Inlet Fiber
4-in. (100-mtn)
Insert Fiher
,IG
Orenco\ superior effluent flters resist cloging better than all other branàs. Our statt-
dard, full-sized 4-in. (100-mm) Biotube Effluent Fiher p\uides maximum long-term
?rotection in a conxplete Package, with housing' Our 4-in. (100-mm) Biotube Jr'' at
hatf the size of our standard model, has more fltering capacily than the full-sized fhers
sold by other manufacturers. For tanþs with existing outlet tees, the Biotube Insert Fiher
is ideal. And for low-profle tanþs, there's the Base Inlet Fiher.
* Covcrcd by patent numl¡ers 5,492,635 aú 4,439'323
To 0rder
Call your nearest Orenco Systems@, Inc' distributor. For nearest distribu-
cor, call Orenco at 800-348-9843 or go to www.orenco'com and click on
"Distributor Locator."
APS-Ff-1
Reu 3.4 @ 11/10
Orenco Systoms@, lnc.
f 'i
,ìl
::;
i¡r
å
. Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfa ction
. lnstalls in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
Standard Features & Benefits
. Easyto clean by
simply hosing off
whenever the tank
needs pumping
. Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
. Corrosion-proof
construction, to
ensure long life
. Lifetime warranty
0ptional
Features &
Benefits
. Alarm available,to
signal the need for
cleaning
. Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
Biotube
Filtering
Process
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluenl
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes'entire
su rfa ce for filtering.
Particles larger than
the Biotube's mesh
are prevented from
leaving the tank.
. Custom and
commercial sizes
available
OrencoSy¡tems'
I r lr-:{.Jl l-:i-}ti?h:: Ll
t,lttn¡iiti.4 ¡fu \Y'it tlt,'
\l',i. rlt/ Í )ac ¡ \l') t t tc ¡ t u ! r r'
ìL.'t
*-:ãr
€
Nomenclatures
¡l-in. Biotube Filter {standard}
FT 04
4-in. Biotube
Effluent Filter
Distributed By:
Extendible PVC handle
inless steel set screws
Top seal plate
Air
Biotube@ filter cartridge
Solid base
Filter housing
¿l-in. Biotube Jr.
Tank wall
--T-
I Options:
Blank = no oPllonsM = flow modulation plate installedA = float bracket atlached
Cartridqe height: 28" and 36" are standard
Houslng helght 36" and 44" are standard
Filt€r diameter (inches)
W = fitsType 3034 outletplpe
S = lits Schedule 40 outlet pipe
Blank = liS" filtrationP = 1/16" liltration
Biotube effluent f¡lter serìes
f-in. Biotube Fifter {base inlet modell
Ff 0822-14 B
0ptions:A = float bracket
FS = 2" oullet orifice
FSO = 2" outlet orifice and overflow plate*
Riser
wall
Base iniet model
Cartridge heighl: I 4" standald
Hous¡ng helghl: 22" standard
Biotube effluent filter ser¡es
Filter diameter (inches)
08=8"
Blank = 1/S" filtrationP = 1/16" filtratlon
CartridgB he¡ght (inches)
tilter diameter (¡nches)
Blank = 1/S" filtrationP = 1/16" filtration
lnsert
For customized opt¡ons (e,9., NC
indicates N0rth Carolina reg¡ons)
fits Typ€ 3034 outlet tee
fits Schedule 40 outlet lee
. Also available wilh coupling and sleeve as a "kit"; FI-0VERFLoWKIT
4-in. BiOfub€ J[. fincludes carridge and housing)
FTJ fH 18 ---T--
I 0ptions:
Blank = no optionsM = flowmodulat¡onplatolnstalledA = float bracket attached
Cartridge height (inches)
Filter diameter (inches)
W = litsType 3034 outletteeS = fits Schedule 40 outlettee
Blank = 'llS" filtrationP = 1fi6" filtrat¡on
Junior series
Biotube effluent f¡¡ter series
¡þin. Biofube Fiher lnsert (cartidse only)
Fr ¡I04 ls -r-
s=
Biotube elfluent f¡ller series
Double Walled PVG Riser & L¡d Options
Poly Lid
(static load bsted to 5m0 bs)¡ Skid reeisûanco surfaæ. Available in greei. Higheot levd of UV Prúct¡m induded. lncludæ a fuam gasket br airtight and
wftrtight applicatione. lndudes squar€ drive scr€urs b disooumge
unauthorized enfy. lnsulation panels adrieve R-10 in$¡lation nating
2|ol
Standald
Orenco @ DuraFiberu Access Lids (FLD)
Not reønmended br vehict¡lar ffic
24'and 30'Diamsbæ. Sol¡d, rosln-infused fibeqlass oonsffi¡ctiono 20,üX)'|b breaking st€ngüt. Standardgf€enorbrcwnoolors. Available wlth or without urcffiane lid gasket
. Available with carbon filüationo 4 stainless steel flathead socket cap scrotils & hex
keywrencfi. lnsulabd lids available -! q 4'
Double Walled PVC Riser
. Available in24'and 30' Diamebr. Cutb lengüt. Sold in +l-2'incrernents. Must be cut bøturcen dbo
Mrlnc.oserulæ
Frq3o5{704 ffiotz
Fæ (f19) g'grn BãE\frb'æ8íãl
IUcË¡lb: wrrw.vdlqpmd.ært
Emll:
Wúcr&
We¡bwebr
cSygtems
¡Prcducis
POLYLOK DISTRTBUTION BOX,
RISER$, Al{D tID
UD€OX O E UD€OX8
-_,____12.45r!+D€OXSEAL
(trflDüOßWflll
.!ca.q
16'SIDE CUT OUT
TO ACCEPT
POLYLOK SEAL
NO.3001 TEAROUT FOR
4" SDR-35 0R
scHD40
NOTTOSCAIE
UD€OX 6'RISER
ROlofL(ilY4'
I
6u
t
@
UD€OX I2'RISER NOTTOSCAIE
POLYLOCK EQUAIJZER
ry.NOTCH'''/ETR
1
É
8Ef LEt/E"rß
Rß8FRf't/DE
F¡f FMAll.f PFED
# É
20' GOVER FOR RISER & DAOX ffor7t)sc/uE
GASKETED SEAL ON
LID & RISER
Wúü&
We¡bwrbr
¡Systems
o Pmducfs
Frol395a704 ãrF&'ru'fl7
P.O.Bo(æ5
Fu: (ft9) gg5€r27 Bm\frte @81211
Wobdb: rnrw.vdqpmd.æm
Emdl¡ tonUæk@mll€mteæ.ønffi¡IDG.¡serulce
Ouick4 Plus
All-in-One Periscope
Ouick4 Plus Standard Chamber Ouick4 Plus
All-in-One 12 Endcap
Center Structural Columns
The Ouick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This
chamber can be installed in a 36-inch-wide trench, Like the original line of Ouick4 chambers, it offers advanced
contouring capability with its Contour Swivel ConnectionrM which permits 1O-degree turns, right and left. lt is also
available in four-foot lengths to provide optimal installation flexibility. The Ouick4 Plus All-in-One 12 Endcap, and
the Ouick4 Periscope are available with this chamber, providing increased flexibility in system configurations.
Ouick4 Plus Standard Chamber
. Two center structural columns offer increased stability and
superior strength
o Advanced contouring connections
. Latching mechanism allows for quick installation
. Four-foot chamber lengths are easy to handle and install
. Supports wheel loads of 16,000 lbs/axle with 12" of cover
Quick4 Plus All-in-One 12 Endcap
o May be used at the end of chamber row for an inlet/
outlet or can be installed mid-trench
o Mid-trench connection feature allows construction of
chamber rows with center feed, as an alternative to
inletting at the ends of chamber rows
. Center-feed connection alfows for easy installation of
serial distribution systems
. Pipe connection options include sides, ends or top
Quick4 Plus All-in-One Periscope
. Allows for raised invert installations
. 1B0o directional inletting
. Twelve inch raised invert great for serial applications
t;
Tul.çß,#PLAS
t¡;;l/¡r il AU\lI{\l
,I
L
/Nt
,/l\
/¡
/N
,"1\.
THE QUICK4@ PLUS STANDARD CHAMBER
Ouick4 Plus Standard Chamber Side and End Views
48"
(EFFECTIVE LENGTH)
Quick4 Plus All-in-One 12 Encap Front, Side and End Views
11.2'
13"I'8" INVERT
12"
5.3" INVERTl_
33'
Quick4 Plus All-in-One Periscope
ûUICK4 PLUS
ÀLLIN{ñÊ
{3@'swvEl
o Eå
1,,-l
12.7" INVERT
representative
Holcler.
OUICK4 PLUS
ALL.IN¿NÊ 12
ENDCAP
5'
INFILTRATOR SYSTEMS, INC. STANDARD LIMITED WARRANTY
(a) The structural ¡ntegrily of each chamber, end plate, wedge and other accessory manufactured by lnfiltrator ( "Units"), when installed and
operated in a leachlield of an onsite septic system in accordance w¡th ¡nf¡ltratoas instructions, is warranted to the original purchaser ("Holde¡')
against defect¡ve materia¡s and workmanship for one year lrom lhe date that the septic permit is issued for lhe septic system contain¡ng the Units;
provided, however, that ¡f a septic perm¡t ¡s not required lly applicable law, the waranty period w¡ll begin upon the date thal installat¡on of the
seplic system commences. To exerc¡se ¡ts warranty r¡ghts, Holder must notìfy lnf¡ltrator ¡n wr¡t¡ng at ìts Co¡porate Headquarters in Old Saybræk,
Connecticut w¡thin fifteen (15) days of the alleged defect. lnf¡lftator will suppfy replacement Units for Units determined by lnliltrator to be covered
by thìs Limited Waranty. lnfiltrator's l¡abil¡ty specìf¡cally excludes the cost of removal and/or installat¡on of the Units.
(b)THF LIN,'IIIED WAFRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARF EXCLUSIVE, THERE ARE NO OTHEH WARRANIIES WITH RESPECI
TO THE UNIfS, INCLUDING NO IMPLIED WARRANTIES OF IVERCHANTABILIry OR FITNESS FOR A PARTICULAR PURPOSE
(c) This Limited Waranty shall be voìd if any part of the chamber system ¡s manutactured by anyone other than lnfiltrator. The Limìted Warranty
does not extend to incidental, consequential, special or indjrect damages. lnfiltrator shall not be liable for penalt¡es or ¡iquidated damages,
includ¡ng loss of production and profits, labor and mater¡als, overhead costs, or other losses or expenses incured by the Holder or any thi¡d party.
Specifically excluded from Limited Warranty coverage are damago lo the Un¡ts due to ordinary wear and tear, alleration, acc¡dent, mìsuse, abuse
or neglect of the Un¡ts; the Un¡ts being subi€cted to vehicle traffic or other cond¡t¡ons which are not perm¡tled by the ¡nstal¡alion instructions; failure
to ma¡ntain the min¡mum ground covers set lorth in the installat¡on inslrucl¡ons; the placement of improper materials into the system containing
the Units; failure of the Units or the septic system due to ¡mproper siting or improper sizing, excessive water usage, improper grease disposal,
or ¡mproper operation; or any other event not caused by lnf¡ltrator. This Limited Warranty shåll be void if the Holder fails lo comply with a¡l ot the
terms set forlh in this Limited Waranty. Further, in no event shall lnfillrator be responsible lor any loss or damage to the Holder, the Units, or any
third party resulling from inslallation or shipment, or from any product l¡ability claims of Holder or any third party. For this Limited Warranty lo
apply, the Units must be installed in accordance with all site conditions required by state and locâl codes; all olher applicable laws; and Infiltrator's
installation instruclÌons.
';J. ::'W
(d) No
original
IN FILTRATOR'
systems inc,
6 Business Park Road r P.O. Box 768
Old Saybrook, CT 06475
860.577,7000 r FAX 860.577.7001
800.221.4436
www. i nf i ltratorsystems.comof lnfiltrator has the author¡ty to Çhange or extend this Limited Waranty. No waranty applies to any party other lhan the
The âbove represents the Standard Limited Waranty offered by lnfiltrator. A limited number of slates and counties have different waranty
requ¡remenls. Any purchaser of Units should contact lnfilkator's Corporate Headquarters in OId Saybrook, Co¡recticut, prior to such purchase,
to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units.
I
Quick4 Plus Standard Chamber Specifications
Size (Wx Lx H) 34"x53"x 12" (86cm x 135 cmx31 cm)lnvert Height 0.6u, 5.3u, 8,0" 12.7',
(1.5 cm, 8.4 cm, 18.5 cm, 22.6 cm)Effective Length 48" (122 cm)
THE QUICK4@ PLUS STANDARD CHAMBER
For technical assistance, installation instructions or customer service, call lnfiltrator Systems at 800.221.4436
U. S. Patentsr 4,759,66 1; 5,0'l 7,04'1; 5,1 56,488; 5,336,01 7; 5,401 ,1 1 6; 5,401 ,459i 5,51 f ,903; 5,7 1 6,1 63; 5,588,778; 5,839,844
CanadianPatents: 1,329,959;2,004,564 Otherpatentspend¡ng.
lnf¡ltrator, Equalizer, Qu¡ck4 and Qu¡ck4 Plus are registered trademarks of lof¡lÙator Systems lnc. lnt¡ltrator is a registered
¡s a regjste¡ed lrademark in lMex¡co, Contour Sw¡vel Connection ¡s a trademark of lnfiltrator Systems lnc. @ 2009 lnfillrator
tradernark in France. lnfiltrator Systems lnc.
Systems lnc. Printed ¡n U.S.A.PLUSos1 01 0tsl-2