Loading...
HomeMy WebLinkAboutSubsoil StudyI(t'T l(unw & AssoclatEs, lnc. Geotechnical and Materials Engineers and Environmental Scientists 5020 County Road 154 Glenwood Springs, CO 81601 phone: fax: 945-7988 945-8454 email: An Employcc Orncd Compony marusa.com www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado fiEcÊryË¿) Ë/:fi p S tnt '?f,f.,ñ,,f,i?,.,rur SUBSOIL STUDY FOR FOUNDATION DESIGN PROPOSED RESIDENCE LOT 3, THE RAPIDS SUBDIVISION RAPIDS VIEW LANE (MID VALLEY DRIVE) GARFTELD COUNTY, COLORADO PROJECT NO. 21-7-636 SEPTEMBER 280 2021 PREPARED FOR: JORDÄN ARCHITECTURE ATTN: BRAD JORDAN P.O. BOX 1031 GLENWOOD SPRINGS, COLORADO 81602 b radi ordanarchitect@ gmail.com TABLE OF CONTENTS PURPOSE AND SCOPE OF STUDY PROPOSED CONSTRUCTION SITE CONDITIONS FIELD EXPLORATION SUBSURFACE CONDITIONS . FOUNDATION BEARING CONDITIONS DESIGN RECOMMENDATIONS ............ FOUNDATIONS FOUNDATION AND RETAINING WALLS FLOOR SLABS UNDERDRAIN SYSTEM ............. SURFACE DRAINAGE... LIMITATIONS.. FIGURE 2 - LOGS OF EXPLORATORY BORINGS FIGURE 3 - LEGEND AND NOTES FIGURE 4 - SWELL-CONSOLIDATION TEST RESULTS TABLE 1 - SUMMARY OF LABORATORY TEST RESULTS -1 1- -1 ,' a -3- J aJ 4 5 5 6 7- FIGURE 1 - LOCATION OF EXPLORATORY BORINGS Kumar & Associates, lnc,Project No.2l-7-636 PURPOSE AND SCOPE OF STUDY This report presents the results ofa subsoil study for a proposed residence to be located on Lot3, The Rapids Subdivision, Rapids View Lane (Mid Valley Drive) Garfield County, Colorado. The project site is shown on Figure 1. The purpose of the study was to develop recommendations for the foundation design. The study was conducted in accordance with our agreement for geotechnical engineering services to Jordan Architecture dated July 28, 202I. A field exploration program consisting of three exploratory borings was conducted to obtain information on the subsurface conditions. Samples of the subsoils and bedrock obtained during the field exploration were tested in the laboratory to determine their classification, compressibility or swell potential, and other engineering characteristics. The results of the field exploration and laboratory testing were analyzedto develop recommendations for foundation types, depths and allowable pressures for the proposed building foundation. This report summarizes the data obtained during this study and presents our conclusions, design recommendations and other geotechnical engineering considerations based on the proposed construction and the subsurface conditions encountered. PROPOSED CONSTRUCTION At the time of our study, design plans for the residence had not been developed. The residence and garage are proposed within the building envelope shown on Figure 1. In general, the residence will be a two- story wood-frame structure over a crawlspace with a slab-on-grade garage. Grading for the structure is assumed to be relatively minor with cut depths between about 2 to 4 feet. We assume relatively light foundation loadings, typical of the proposed type of construction. A swimming pool may also be constructed. If building loadings, location or grading plans change significantly from those described above, we should be notified to re-evaluate the recommendations contained in this report. SITE CONDITIONS The lot was vacant and appeared to have had minor cut and fill grading, likely during the subdivision development. The ground surface is mostly relatively flat within the building envelope steepening at the lot rear to about 15 to 20 degrees on the west downhill slope, and then decreasing to about 2 to 4 degrees down to the west and southwest toward the Colorado River. Kumar & Associates, Inc.Project No.21-7-636 1-L- A dry drainage traverses approximately along the southem property line. Vegetation consists of sparse grasses and weeds within the building envelope and relatively small to large trees and shrubs adjacent the river. A well is located near the southwest building envelope corner. FIELD EXPLORATION The field exploration for the project was conducted on August 30,2021. Three exploratory borings were drilled at the approximate locations shown on Figure 1 to evaluate the subsurface conditions. The borings were advanced with 4-inch diameter continuous flight augers powered by a truck-mounted CME-458 drill rig. The borings were logged by a representative of Kumar & Associates, Inc. Samples of the subsoils and bedrock were taken with 1%-inch and 2-inch I.D. California or split- spoon samplers. The samplers were driven into the subsoils at various depths with blows from a 140-pound hammer falling 30 inches. This test is similar to the standard penetration test described by ASTM Method D-1586. The penetration resistance values aro an indication of the relative density or consistency of the subsoils and hardness of bedrock. Depths at which the samples were taken and the penetration resistance values are shown on the Logs of Exploratory Borings, Figure 2. The samples \Ã/ere returned to our laboratory for review by the project engineer and testing. SUBSURFACE CONDITIONS Graphic logs of the subsurface conditions encountered at the site are shown on Figure 2. Below the topsoil or fill soils, the subsoils consist of about 3/zto 7% feet of very stiff/medium dense silt and sand overlying very dense, slightly silty sand, gravel and cobbles with probable small boulders underlain in Boring 1 at a depth of 12 feet by very hard siltstone bedrock. A 3%-foot thick layer of very silty, clayey sand fill with organics was encountered below the topsoil of Boring 3. This fill was probably placed as part of initial subdivision development. Laboratory testing performed on samples obtained from the borings included natural moisture content and density, swell-consolidation and percent silt and clay-sized particles. Results of swell-consolidation testing performed on relatively undisturbed drive samples of very silty sand soils, prescnted on Figurc 4, indicate low compressibility under existing low moisture conditions and light loading and minor to low collapse potential on the samples when wetted under loading. The laboratory testing is summarizedinTable 1. Kumar & Associates, lnc.Project No.21-7-636 -J- No free water was encountered in the borings at the time of drilling and the subsoils and bedrock were slightly moist to moist. FOUNDATION BEARING CONDITIONS The upper silt and sand soils encountered in the borings possess low bearing capacity and typically a low settlement potential if wetted. Existing filIpresents risk of post-construction movement and is unsuitable for support of new foundations. Shallow spread footings placed on the natural silt and sand soils can be used for support of the proposed residence with a risk of foundation movement mainly if the bearing soils become wetted. V/e should observe the soil conditions exposed at the time of excavation and evaluate them for swell-compression potential and possible mitigation. Proper surface drainage as described in this report will be critical to the long-term performance of the structure. A low settlement risk can be achieved by extending the bearing level down to the relatively dense, coarse granular soils. Although groundwater was not encountered in our borings, the groundwater level could rise to near the top of the sand, gravel and cobble layer during seasonal high water of the river and be encountered in deep excavations. In general, below-grade construction should be limited to a floor or crawlspace level at least 2 feet above the anticipated maximum groundwater level (typically assumed as 100 year river flood elevation). DESIGN RECOMMENDATIONS FOUNDATIONS Considering the subsurface conditions encountered in the exploratory borings and the nature of the proposed construction, the building can be founded with spread footings bearing on the upper natural silt and sand soils with a settlement risk or on the deeper, coarse granular soils. The design and construction criteria presented below should be observed for a spread footing foundation system. 1) Footings placed on the undisturbed natural silt and sand soils should be designed for an allowable bearing pressure of 1,500 psf. Footings placed entirely on the underlying, relatively dense, coarso granular materials can be designed for an allowable bearing pressure of 3,000 psf. Based on experience, we expect initial settlement of footings designed and constructed as discussed in this section will be about 1 inch or less. Additional differential settlement up to about I inch could occur if the silt and sand bearing soils are wetted. Kumar & Associates, Inc.Project No,21-7-636 -4- 2)The footings should have a minimum width of 18 inches for continuous walls and 2 feet for isolated pads. Exterior footings and footings beneath unheated areas should be provided with adequate soil cover above their bearing elevation for frost protection. Placement of foundations at least 36 inches below exterior grade is typically used in this area. Continuous foundation walls should be heavily reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure corresponding to an equivalent fluid unit weight of at least 55 pcf for the on-site silt and sand soil as backfill. Topsoil, filI and any loose disturbed soils should be removed and the footing bearing level extended down to the firm natural soils. The exposed soils in footing area should then be moistened and compacted. A representative of the geotechnical engineer should observe all footing excavations prior to concrete placement to evaluate bearing conditions. 3) FOTINDATION AND RETAINING WALLS Foundation walls and retaining structures which arelaterally supported and can be expected to undergo only a slight amount of deflection should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 50 pcf for backfill consisting of the on-site fine-grained soils. Cantilevered retaining structures which are separate from the residence and can be expected to deflect sufficiently to mobilize the full active earth pressure condition should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of at least 40 pcf for backfill consisting of the on-site flrne-grained soils. All foundation and retaining structures should be designed for appropriate hydrostatic and surcharge pressures such as adjacent footings, traffrc, construction materials and equipment. The pressures recommended above assume drained conditions behind the walls and a horizontal backfill surface. The buildup of water behind a wall or an upward sloping backfill surface will increase the lateral prossure imposed on a foundation wall or retaining structure. An underdrain should be provided to prevent hydrostatic pressure buildup behind walls. Backfill should be placed in uniform lifts and compacted to at least 90o/o of the maximum standard Proctor density at a moisture content near optimum. Backfill placed in pavement or structural areas should be compacted to at least 95Yo of the maximum standard Proctor density 4) s) 6) Kumar & Associates, lnc Project No.21-7-636 -5- Care should be taken not to overcompact the backfill or use large equipment near the wall since this could cause excessive lateral pressure on the wall. Some settlement of deep foundation wall backfill should be expected even if the material is placed correctly and could result in distress to facilities constructed on the backfill. The lateral resistance of foundation or retaining wall footings will be a combination of the sliding resistance of the footing on the foundation materials and passive earth pressure against the side of the footing. Resistance to sliding at the bottoms of the footings can be calculated based on a coefficient of friction of 0.35 for on-site fine-grained materials. Passive pressure of compacted backfill against the sides of the footings can be calculated using an equivalent fluid unit weight of 325 pcf for on-site fine-grained materials. The coefficient of friction and passive pressure values recommended above assume ultimate soil strength. Suitable factors of safety should be included in the design to limit the strain which will occur at the ultimate strength, particularly in the case of passive resistance. FLOOR SLABS The natural on-site soils, exclusive of topsoil and fill, are suitable to support lightly loaded slab- on-grade construction with a risk of settlement if the bearing soils are wetted. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4-inch layer of relatively well graded sand and gravel such as road base should be placed beneath interior slabs for support. This material should consist of minus 2-inch aggregate with at least 50o/o retained on the No. 4 sieve and less than l2o/o passing the No. 200 sieve. Required fill beneath slabs can consist of the onsite soils, excluding topsoil and oversized rocks. The fiIl should be spread in thin horizontal lifts, adjusted to near optimum moisture content, and compacted to at least 95%o of the maximum standard Proctor density. All vegetation, topsoil and loose or disfurbed soil should be removed prior to fill placement. UNDERDRAIN SYSTEM Although groundwater was not encountered during our exploration, it has been our experience in the area that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. Therefore, Kumar & Associates, lnc.Project No.21-7-636 -6- we recommend below-grade construction, such as deep crawlspace and basement areas, be protected from wetting by an underdrain system. The drain should also act to prevent buildup of hydrostatic pressures behind foundation walls. Typical depth crawlspace of 4 feet or less and slabs-at-grade, such as a garugq should not need an underdrain with appropriate foundation wall backfill construction as recommended below in the "surface Drainage Section". Where provided, the underdrain system should consist of a drainpipe surrounded by free- draining granular materialplaced at the bottom of the wallbackfill. The drain lines should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade, and sloped at a minimvm lo/o grade to a suitable gravity outlet. Free-draining granular material used in the drain system should consist of minus 2-inch aggregate with less than 50Yo passing the No. 4 sieve and less than2Yo passing the No. 200 sieve. The drain gravel should be at least I%feet deep. An impervious liner, such as 20 mil PVC, should be placed below the drain gravel in a trough shape and attached to the foundation wall with mastic to keep drain water from flowing beneath the wall and to other areas of the building. SURFACE DRAINAGE It will be critical to the building performance to keep the bearing soils dry. The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95Yo of the maximum standard Proctor density in pavement and slab areas and to at least 90o/o of the maximum standard Proctor density in landscape aroas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in paved areas. Graded swales should have a minimum slope of 3%. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Landscaping which requires regular heavy irrigation should be located at least 10 feet from foundation walls. Consideration should be given to use of xeriscape to reduce the potential for wetting of soils below the building caused by inigation. Kumar & Associates, lnc.Project No.21-7-636 -7 - LIMITATIONS This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. \Ve make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory borings drilled at the locations indicated on Figure 1, the proposed type of construction and our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Our findings include interpolation and exhapolation of the subsurface conditions identified at the exploratory borings and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified so that re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. Vy'e are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to veriff that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. Respectfu lly Submitted, Kumar & Associates, Inc. Mark , E.I.T. Reviewed by: Steven L. Pawlak, SLP/kac (t,15222 Kumar & Associates, lnc.Projec{ No,21-7-636 o(ohULITJI;óUItilt--o>ioÉ.fL(Lo<Ìo\l.¿_sèsIL-)è('Yè\-&'ØQ.-Qðc9\'-ji25-O'E25.O'Iot 2ùîO.O' lltl¡ty DrcinqgeØd lr¡goti@ Eæffiqt2O-O'DroinøgeEowØtpu Ræ No. 639203.''o('\\ÐrchogpEoffiãtd.ñs,--",}0)'ufiittmd lñlgotìoaIIRec,tt(,\\:-ll{¡/\,'////lil/// /,'//l/"//i//// iL/l/i-/ì-II!¡(9zÉ,oE(d',|162')uT"tÌI\\J/r,/¡9z\ OE)@,[ot 387,703 Sq Ft2.01 oN(9-æ,o@rl)FO(()Ir'.Ic\(no(E'ıoØØoðLoEJ\¿(n()z.E.ocoÉ.oFÉ.oJo_xtrJl!oz.Otrc)OJC')l!uDça:tl - r¿o¿ '62 9 BORING 1 EL. 5502.5 BORING 2 EL. 5502.5' BORING 3 EL. 5502' 0 0 17/12 WC=4.0 DD= 1 00 17/12 1e/12 WC=9.2 DD=112 -2OO=47 5 5 17/12 18/ 12 WC=7.8 DD= 1 00 -2O0=41 1s/ 12 WC=5.5 DD=99 l-- LJt!tL I-F-IL LJô 10 50/ 4.5 31 /6, 50/5 10 F LJ t¡JtL I :EFfLt¡lo 31 /6, 56/6 15 1553/6 20 20 21 -7 -636 Kumar & Associates LOGS OF TXPLORATORY BORINGS Fig. 2 Its I E I I IÈ I LEGEND n TOPSOIL; ORGANIC SANDY SILT, SLIGHTLY MO|ST, BROWN. FILL; VERY SILTY, CLAYEY SAND WITH ORGANICS, SCATTERED GRAVEL, MEDIUM DENSE, MOIST, DARK BROWN. stLT AND SAND (ML-SM); VERY STIFF/MEDIUM DENSE, SLIGHTLY Mo|ST, LIGHT BROWN. SAND, GRAVEL AND COBBLES (SM-GM); SLIGHTLY SILTY, PROBABLE SMALL BOULDERS, VERY DENSE, SLIGHTLY MOIST TO MOIST, BROWN AND TAN, ROUNDED ROCK. SILTSTONE BEDROCK; VERY HARD, SLIGHTLY MOIST, GRAY. DRIVE SAMPLE, 2-INCH I.D. CALIFORNIA LINER SAMPLE. ¡ DR|VE SAMPLE, 1 3/1-INCH l.D. SPLIT SPOON STANDARD PENETRATION TEST. 4it.ı DRIVE SAMPLE BLOW COUNT. INDICATES THAT 17 BLOWS 0F A 140-P0UND HAMMERtt/ t¿ FALLTNc Jo TNcHES wERE REQUTRED To DRtvE THE sAMpLER 12 tNcHES. PRACTICAL AUGER REFUSAL. NOTES 1. THE EXPLORATORY BORINGS WERE DRILLED ON AUGUST 30, 2021 WITH A 4-INCH DIAMETER CONTINUOUS-FLIGHT POWER AUGER. 2. THE LOCATIONS OF THE EXPLORATORY BORINGS WERE MEASURED APPROXIMATELY BY PACING FROM FEATURES SHOWN ON THE SITE PLAN PROVIDED. 5. THE ELEVATIONS OF THE EXPLORATORY BORINGS WERE OBTAINED BY INTERPOLATION BETWEEN CONTOURS ON THE SITE PLAN PROVIDED. 4, THE EXPLORATORY BORING LOCATIONS AND ELEVATIONS SHOULD BE CONSIDERED ACCURATE ONLY TO THE DEGREE IMPLIED BY THE METHOD USED. 5. THE LINES BETWEEN MATERIALS SHOWN ON THE EXPLORATORY BORING LOGS REPRESENT THE APPROXIMATE BOUNDARIES BETWEEN MATERIAL TYPES AND THE TRANSITIONS MAY BE GRADUAL. 6. GROUNDWATER WAS NOT ENCOUNTERED IN THE BORINGS AT THE TIME OF DRILLING. 7. LABORATORY TEST RESULTS: WC = WATER CONTENT (%) (ASTM D2216); DD = DRY DENSITY (pct) (nsrv D2216); _2OO= PERCENTAGE PASSING NO. 2OO SIEVE (ASTM Dl140). I LEGEND AND NOTES Fig. 521 -7 -636 Kumar & Associates E : I a; SAMPLE OF: Very Silty Sond FROM:Boringl@2.5' WC = 4.0 %, DD = 'l 00 pcf ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WEÏTING N JJl¡l =tJ1 I zo =o =oØz.o(J às JJ LJ =t/1 I z.otr o =o U1z.oo 1 0 -1 2 -3 -4 1 0 -1 2 1001.0 APPLIED PRESSURE - KSF APPLIED PRESSURE - KSF t0 l0 SAMPLE OF: Very Silty Sond FROM:BoringS@5' WC = 5.5 %, DÐ = 99 pcf ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WETTING ) Ih.r. t.!t r.!ull! opply only to the 3oñpl6! t !t.d. Ihe {.sting rcport rholl not bo r.prcducod,.xcôpt ìn full. without thc wr¡tton opÞrcvol of(umor qnd A8soclotas, lnc, Svsll Consolidotion tolting p.rform.d in occordonc! *¡th ASÍU 0-4546, -5 Fig. 4Kumar & Associates SWELL_CONSOLIDATION TEST RESULTS21 -7 -636 lGrtffilfiffi:ffi*rïËü**TABLE 1SUMMARY OF LABORATORY TEST RESULTSNo.2l-7-636Very Silty SandVery Silty SandVery Silty Clayey Sandßil1)4l47SOILTYPEVery Siþ SandLIQUID LIMIT1004.02Y2A1GRADATIONSAMPLE LOCATIONDEPTHBORINGUNCONFINEDCOMPRESSIVESTRENGTHPLASTICINDEXPERCENTPASSING NO.200 stEvENATURALDRYDENSITYNATURALMOISTURECONTENTSANDl:/"1GRAVEL(%)1007.852JIT2992y,59.25.3