HomeMy WebLinkAboutOWTS Design,l29 C¡lt¡s L¡rur
CnReoNonLE,CO A1623
970.309.5259
CARLA. oSrBERG@GMAIL. coM
sltt"rl( -r ( :()lÌsttr¡.,1.I :\.{t
December 19,2021 Project No. C1654
Kevin Hoffman
kevin. h. hoffman@qmail. com
Onsite Wastewater Treatment System Design
&Bedroom Residence + 1-Bedroom Attached Apartment
998 Huebinger Drive
Garñeld County, Colorado
Kevin,
CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 2.839-acre property is located outside of Glenwood
Springs, in an area where OWTSs are necessary.
Legal Description: Section: 2 Township: 7 Range: 89 Subdivision: WESTBANK RANCH PUD #4 RESUB
Lot 37
Parcel lD: 239502406037
SITE CONDITIONS
A 3-bedroom, single-family residence presently exists on the property and is served by an existing
OWTS. The OWTS consists of a 1000-gallon, two-compartment concrete septic tank followed by an
lnfiltrator@ chamber system. Garfield County Individual Sewage Disposal System Permit2742
documents this system. The system was sized to accommodate 3 bedrooms. The permit received final
approval on July 28, 1997.
A 1-bedroom apartment is being added to the residence. There is a need to upgrade the OWTS to
accommodate this addition. The existing OWTS will be abandoned and replaced with the OWTS
proposed in this design.
The residence is cunently served potable water from a community water system. The water line enters
the southeast comer of the residence. The water line will not come within 25-feet of any OWTS
component.
The proposed soiltreatment area (STA) location to the northwest of the residence has an approximate
ten percent slope to the northeast. The area is vegetated with native grasses and sage.
There should be no traffic or staging of material over the future STA site to avoid compaction of soilspriorto construc{ion of the STA
It should be noted that no survey was provided to create the síte plan. GPS coordinates and a Google Earth
image were used to create the site plan. Placement of existing and proposed features and components may
not be accurate. The northwestem property line has been verified on the properly.
Page2
Photos and measurements of property line to the northwest
SUBSURFACE
Hepworth-Pawlak Geotechnical, Inc. Subsoil Study for Foundation Design and Percolation Testing report
dated December 6, 1996, Job No. 196 584 is enclosed.
Three percolation tests were conducted, and a soíl profile test pit excavated. Percolation tests were
conducted at47 % inches in depth, 52lzinches in depth, and 50 inches in depth with results of I minutes
per inch (MPl), 10 MPl, and 10 MPl, respectively.
The Profile Pít consisted of topsoíl to 1-foot, underlain by clay and sand (silty, scattered gravel, occasional
cobble, stiff, loose to medium dense, slightly moist, light reddish brown, slightly porous and calcareous,
angular siltstone/sandstone fragments) to 7.O-feet, underlain by clay (silty, sandy, stiff, slightly moist, reddish
brown, slightly to moderately porous, slightly to moderately calcareous) to a maximum depth explored of 9.0-
feet. No bedrock or groundwater was encountered.
While the soil investigation was performed many yearc ago, the location of the testing is in the proposed STA
location and the area remains undisturbed. Results are relevant for design purposes. Current regulation
I
h
Page 3
does require a m¡nimum of TWO soil profile pit excavations. Prior to construction, an addit¡onal test pit
must be excavated, and this office must be called to verify soils are consistent with those described
in the Hepworth-Pawlak rêport
Based on the information presented in the Hepworth-Pawlak report, soils align with Soil Type 2. We are
sizing the STA based conservatively on Soil Type 2A. A long term acceptance rate (LTAR) of 0.5
gallons per square foot will be used to design the OWTS.
DESIGN SPEGIFICATIONS
The existing OWTS will be abandoned. The existing septic tank will be pumped and the sides, top, and
bottom crushed and the remaining void filled with onsite material. The existing STA will be abandoned in
place.
Desion Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 4 Bedrooms = 600 GPD
LTAR = 0.5 GPD/SF
600 GPD / 0.5 GPD/SF x 0.8 (pressure dosed trenches) x 0.7 (chambers) = 672 SF
The ne¡v O1^,TS design is based on 4-bedrooms. An average daily wastewater flow of 600 GPD will be
used.
For the purposes of this OWTS design, Benchmark Elevation has been established the sewer line exiting
the residence as 100'. CBO lnc. should be notified of any discrepancies or problems with grade
elevations of proposed components during installation of the OWTS.
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions.
The 4-inch diameter SDR-35 sewer line exiting the residence must have a double-sweep clean out and a
minimum 2o/o grade to the septic tank.
The system installation must include a 150O-gallon, two-compartment concrete septic tank with an
effluent filter on the outlet tee. Risers must bring the manhole lids to grade for access. lf more than one
riser is added to the septic tank, an extension handle must be installed on the effluent filter-
The installation must include a 1S00-gallon, two-compartment lnfiltrator@ poly septic tank with an Orenco
Biotube Effluent filter on the outlet tee, followed by a 500-gallon, lnfiltrator@ poly pump chamber with an
Orenco@ ProPak pumping system and an Orenc@ PF3005 pump. The floats must be set to dose
approximately 80 gallons each pump cycle, allowing for approximately 12 gallons of drain back into the
pump chamber after each pump cycle. A pump curve is enclosed. The control panel for the pump must be
located within line of sight of the septic tank. We recommend Valley Precast out of Buena Msta be
contracted for start-up of the pumping system.
OWTS Gomoonent Minimum Elevation
Primary Tank lnlet lnvert Approximate horizontal distance 13' / min. 2o/o fall I
min.3.25" fall
Automatic Dístributing Valve (ADV)Approximate horizontal distance 113'l mín. 1% rise
for drain back / min, 14.125" rise
lnfiltrative Surface Approximate horizontal distance to furthest trench
32' I min.1o/otall / min. 4" lall
Page 4
Table
A 1.S-inch diameter Schedule 40 pump line must be installed from the pump to an Orenco@ automatic
distributing valve (ADV), model6404. This pump line willcross the driveway. We recommend a minimum
$chedufe 40 conduit to run underthe driveway. This pump line must have a minimum 1o/o gradefor
proper drain back into the tank after each pump cycle. The ADV must be placed at a high point in the
system in an insulated riser with access from grade. Screened rock must be placed below the ADV to
support the ADV and to assure the clear pipes exísting the ADV remain vísible for future inspection and
maintenance.
Effluent will be pressure dosed through 1.S-inch diameter pipes to four trenches, each with 14 'Quick 4'
Standard Plus lnfiltrator@ chambers, for a total of 56 chambers and 672 square feet of ínfiltrative area.
There must be at least 4-feet of undisturbed soil between each trench, although we recommend 6-feet
where feasible. Effluent will be pressure dosed to 1.5-inch diameter laterals, which must be hung with zip
ties from the underside of the chambers. Laterals will have 5/32-inch diameter orifices facing up, with the
exception of the first and last holes facing down for drainage. Orenco@ Orifice Shields may be placed
under each downward-facing orifice. The orifices must be placed 3-feet on center. Each lateral must
end in a 90-degree ell facing up with a ball valve for flushing. Valves may be placed in a valve box,
accessible from grade, for access. lnspection ports must be placed at the beginning and end of each
trench. Ports may be cut to grade and covered with a valve box for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contrac{ors and engineers in this area.
GBO lnc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
Dose Range Max = 162 gal- (600 GPD x25o/"
+ 12 oal drain back)
Min. 56 gal. (11 gal x 4) + 12 gal
drain back
Dose Setting 80 gallons/dose 12 gallons drain back (1'13' I 1.5"
diameter pumo line)
Float Separation 5O0-gallon lnfiltrator@ poly pump
chamber
6" on/off float separation
Pump Criteria 12.9 gallons per minute (GPM)25.6 feet totaldynamic head
fiDH)
COMPONENT MANUFAGTURER MODEL NO.GOMMENTS
Septic Tank lnfiltrator@ Item # IM-1520-2CP 2-compartment poly
seotic tank
Effluent Filter Orenco@ 4-inch diameter full size
effluent filter
Pump Chamber lnfiltrator@ Item # |M-540-HH Pump chamber with high-
head pump
Pump Orenc@ PF3005111/'HP
120 Volt
Biotube ProPak Pump
Packaqe
OrencoG)BPP3ODD Vault, Filter, Control Panel
ldemand dose)
Tank Risers and Lids Orenco@ Double-walled PVc R¡sers ancl
Lids (24" diameter)
ADV Orenco@ v64044 1.5" lnlet and Outlets
ADV Riser and Lid Orenco@ Double-walled PVC Risers
and Lids (30" diameter)
Page 5
Construction must be according to Garfield County On-Site Wastewater Treatment System Regulations, the
owTs Pennit provided by Garfield county Building Department, and this design.
INSTAL¡-ATION GONTRACTOR
CBO lnc. expects that the installer be experienced and qualified to perform the scope of work ouüined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional e¡nditions in this design or county pennit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO lnc. must view the OWTS during construction. The OWTS observation should be perfonned before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applícable, must also be observed. CBO lnc. should be notified 48 houri
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.O of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our instãllation
documentation.
REVEGETATION REOUIREMENTS
An adequate layer of good quality topsoil capâble of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well witñ
successional species. No trees or shrubs, or any vegetation requiring regular inigation shall be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing theproperty. The property owner is responsible for maintaining service contracts for manufactured units,
alternatíng STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For exampb, ã
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
Orif¡ce Shields Orenc@ os150 1.5 inch diameter (72 total)
Flush¡ng Assembly Orenco@ 1.5" cliameter lz) 45" or 90" long sweep only(4 total)
Chambers Inf¡ltrator@ Standard PIus 56 Standard Plus'Quick 4'
chambers
Page 6
lf an effiuent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and nonùiodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the Oì^/TS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submitted. lf soil conditions encountered are different from conditions
described in report, CBO lnc. should be notified. All OWTS construction must be accolding to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO lnc.Reviewed By:
(ø¡'tü tsthrug
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
Shosi 1 0F 4w1.0Designed by: CBODatet 12h912021by: RBDDReviewêdDrawn by:Hoffman Residence998 Huebinger DriveGarlield County, ColoradoProjectNumber: C1654N_zSCALE: I = 50'=0-STA-\.or.*r"LINESEPTICTANKSADDITIONAL TEST PITREQUIRÊD PRIOR TOINSTALLATIONWATER LINE ENTERSSOUTHEAST CORNER OF HOUSERESIDENCEWITH AN ATTACHED1-BEDROOM APTTHE LOCATION OF PROPOSED IMPROVEMËNTS SHOWN ARENOl THE RËSULT OF A FROPÊRW SURVEY. 'T}IE LOCATIONSARE APPROXIMATE. IT IS THE HOMEOWNERS' DUTY fOENSURE ALL CONSTRUC'TION AND IMPROVÊMÉNT LOCATIONSARE ACCURATE. PROPERTY LINÊS AND SE'IBACK DISTANCËSSHOULO BE CONFIRMËD PRIOR TO EXCAVATION, SCALEDFOR PRINTING ON 1'I"17 PAPER,DRAWNGS MUST BË USED INCONJUNCTION WITH DESIGNLETTER DATED 121 1 gI2O21w2.0CBO lnc-f29 Cains LaneCarbondal6, Colorâdo 81 623Phone 970.309.5259carla.ostborg@gmâil.ôom
Sheet 2 0F 4w2.0ooSBEDROOMRESIDENCEWITH I.BEDROOMATÎACHED APT\\15OO-GALLON z.COMPARTMÊNT POLY SEPTICPLACE PUMP LINE IN MIN. SCHEDULE 40CONDUITUNDER DRIVEWAYAPPROX. LOCATION OF EXISTINGSTA TO BE ABANDONED. TANK FOLLOWED BYAsOO-GALLON POLY\ putr¡p cg¡NeeR wrrH AN oRENco puMprNcSYSTËM, RISERS AND LIDS TO GRADEHoffman Residence998 Huebinger DriveGârfield County, ColoradoPrcject Number C1654loártet 121ßno2'lloeslgneo uy: cgoI Reviswed by: RBlDrawn by: DDCBO lnc.129 Cains LansCarbondale, Colorâdo 81623PhonÊ 970.309.5259carla.ostberg@gmail,comPROPERTYFLUSHING VALVE ATEND OF EACH LATERAL4' DIA SDR.35 INSPECTION PORT ATBEGINNING ANÐ END OF EACH TRENCH4 TRENCHES EACH WTH 14 'QUICK 4' CHAMBERS = 5 CHAMBERS= 672 SF.I,5" DIA SCH4O PVC SUSPENDED LATÉRALS WITH 5/32" DIAORIFICES 3' O,C. FACING UP, FIRST AND LAST ORIFICES FACINGDOWN FOR DRAINAGE COVERED WITH ORIFICE SHIETDS1.5' DIA SCH-40 DISTRIBUTION LINES TO EACHTRENCHEXISTING SEPTIC TANKTO BÊ ABANOONEDBM 100'4" DIA SDR.35 SEWERPIPE WTH CLEANOUTMIN 2% FALL TO TANKADV MODEL 6404 AT HIGH POINTACCESSIBLE AT GRADE1.5'DIA SCH.4O PUMP LINÊ,(MIN 1% DRAIN BACK TO TANK)NffiSCALE: 1" = 20'-0'
Sheet 3 0F 4w3.01A1912021by: CBOby:by: RBDDHofünan Resldence998 Huebinger DriveGarff eld County, ColoradoProjsctNumber: C1654ÎRATORGRAVÉLLESS QUlcK.4'CHAMBER (4'x 3')ENI' PLAÎEDIA SCH-40DISÎR¡BUÎION LINÊ 1OEÀCH TRENCII1.5',DIA SCH-40EFFLUENÍ PIPË FROMDtq sDR.35INSPECfIONPORlADV WTH ACCESS AT4' maxLGRADEsotLPLACED IN IOP PORT2'minl. OF CHAMBER END PLAÍES\-olstareurorl r-rNE rooIHER TRENCH (4TOTAL)L¡MITEXCAVATIONSUSPEND LATERAIS WTHZIP.ÍIES IO UNDERSIOEOF CTIAMBÊRS,outcK{'DIASDR€s INSPÊCTONCHAMEER(4r3)PORT AT BËêINNING ANDEND OF EACH TRENCHSURFACÊEND EACH LATERAL IN A 90' LONGSWEEPING ELI FACING UP WIÍH A BALLVALVE IN A VALVE BOX ACCÊSSIBLÊ A1GRAI]EI.5" DIA SCH4O PVC SUSPENDEO LAÎERALwllH 5r3u DtA oR|FICES Al3' O.C. FACtNcUP. FIRST AND LASI ORIFICES FACE OOW{WÍTII AN ORIFICE SHIELD FOR DRAINAGE¡4\CHAMBER IRENCH SEClloN\?_nlrtfæoË4lEEE-JBsqS* ftrNA,v4,Hsr¡u rLus"t*cVALVË ECCENTRIC TOCÊNTER OF VALVESMALL VALVE COVÊRBOX OR IRRIGATONVALVE BOX À1 GRADE30'DIAMETER PVC10'DIAVALVE 8OXWITH SECUREO LIOI,5'PVC SLIP X MALEPIPE THREADADAPTERW/CAPRISERDIA BALLCAP OR IHREADEDVALVECLEÀNOUT ASSEMBLY1.5" DIA SCH.40 PVCLONG SWEEP 90'ELBOWCOMPACTDIS'ÍRIBUTINGVALVE ASSEMBLYBASE fO SUPPORIBOXPIPE CUt 10FITFROMÊND CAPUSE HOLE SAWTOCI,JT IHRU TOP OFPUMPINGJ.S DtA SCH-40PVC INLÊÍANDOUTLETS't.5i DtA scH40 PVCSUSPENDED LATERALEND(Ð.llsieEgllsrsL!$EfcH AMBERA AUTOMATIC OISIRIAUÌNG\?r---.BrñiEVAIIE DÊTAIL/ÀFLUS}IING VALVE OETAIL\3,r--rtræC8O lnc.129 Cains LânaCarbondalê, Colot'ado 81623Phone 970.309.5259carla.ostberg@gmâ¡l,com
Pump Selection for a Pressurized System - Single Family Residence Project
998 Huebinger Drive
Parameters
300Discharge Assembly Size
Transport Length Beforô Valve
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Transport Length After Valve
Transport Pipe Class
Transport P¡po Size
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Laleral P¡pe Class
Lateral Pípe Size
Orifice Size
Orifìce Spacing
Residual Head
Flow Meter
Add-on' Friction Losses
Calculations
1.50
113
40
1.50
6404
32
40
1.50
15
0
40
1.50
4
56
40
1.50
5132
3
5
None
0
feet
inches
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
Íæl
250
100
I
oolt
-o
doo
c
og
cl
6
oF
200
50
Minimum Flow Rate per Orifice
Numbsr of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
oÁ Flow Differential lsvLast Orif¡ce
Transport Velocity Before Valve
Transport Velocity Afier Valve
Frictional Head Losses
0.68
19
12.9
1
2.O
2.ø
2.O
50
gpm
9pm
o/o
Os
þs
00
feet
feet
feet
feet
fêet
feet
fe€t
feet
0.5
1.2
2.6
0.4
0.0
0.2
0.0
0.0
gâls
gals
gals
gals
gals
gals
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport ãfter Valve
Loss in Manifold
Loss in Lalerals
Loss lhrough Flowmeter
Add-on'Fdclion Lossês
Pipe Volumes
s10 15 20 25
Net Discharge (gpm)
30 35 40
PumpData
Vol of Transport Line Before Valve
Vol of Transport L¡ne After Vâlve
Vol of Man¡fold
Vol of Laterals per Zone
Totia¡Vol Before Valve
Total VolAfterValve
11.9
3.4
0.0
5.9
11.9
9.3
PF3005 High Head Efluent Pump
30 GPM, 1/2HP
1T5nsOV 1Ø 6OHz,2OOV 3Ø 6OHz
PF3007 High Hêad Effiuent Pump
30 GPM,3/4HP
23OV 1Ø6OHz,2OOí46OY 3Ø 60Hz
PF301O High Head Emuent Pump
30 GPM, lHP
23OY 1Ø 6OHz.2OO|46OY 3Ø 6OHz
PF30l5 High Head Effuent Pump
30 GPM, 1-ll2HP
23OV 1Ø 6OHz,2OO|23O|46OV 3ø 6OHz
gpm
feet
I
I
\
System Curve: -
Pump Curve: *'
Pump Opt¡mal Range:-
i\
operat¡ng Point
êJ
o
Des¡gn Po¡nt:
sY$'tÈ1Ml;