Loading...
HomeMy WebLinkAboutHigh Strength Bolt Inspection ReportWest Slope Testing & Inspection LLC Report #1 3177 Glendam Dr. Grand Junction, CO 81504 Page 1 of 1 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Dates: 10-18-21 & 10-19-21 Project: Switzer Residence Finnbar Ranch Address: 33 Saint Finnbar Farms Rd. Carbondale, CO Building Permit No: BLRE-07-21-6979 General Contractor: Maley Building Corp. Contractor that Performed Work: Black Magic Welding Inspection of shop fabrication or field work at job site: Field Report: Visually inspected the complete joint penetration field welding in process at the bent beam to column moment connections steel frame grid line 3. Above inspections included verification of welder qualifications/w.p.s., use of proper welding electrodes/materials, inspection of the joint preparation, root pass welds, random observations of the intermediate weld pass layers, and a final inspection of the completed welds. Also inspected field fillet welding at the column shaft bases to embeds steel frame columns grid line 3, wood saddle/knife plate assemblies to W 14x68 steel beam grid line L, and inspected high strength A325 bolting at the steel beam & column connections. The onsite welding & high strength bolting inspected above appeared to be in substantial conformance with the plans, and the quality requirements of the AWS D1.1 Structural Welding Code & the AISC/RCSC Specification for high strength bolting. Inspector/Technician: Douglas E Young Douglas E. Young ICC Certification #5102224 Structural Welding Special Inspector uctural Ste 1 �& hbltin Special Inspector p ay- pplie Firep�r g pecial Inspector ® Douglas E Young CWI 96070131 QC1 EXP. 7/1/2023