HomeMy WebLinkAboutHigh Strength Bolt Inspection ReportWest Slope Testing & Inspection LLC Report #1
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Dates: 10-18-21 & 10-19-21
Project: Switzer Residence Finnbar Ranch
Address: 33 Saint Finnbar Farms Rd. Carbondale, CO
Building Permit No: BLRE-07-21-6979
General Contractor: Maley Building Corp.
Contractor that Performed Work: Black Magic Welding
Inspection of shop fabrication or field work at job site: Field
Report: Visually inspected the complete joint penetration field welding in process
at the bent beam to column moment connections steel frame grid line 3. Above
inspections included verification of welder qualifications/w.p.s., use of proper
welding electrodes/materials, inspection of the joint preparation, root pass welds,
random observations of the intermediate weld pass layers, and a final inspection of
the completed welds.
Also inspected field fillet welding at the column shaft bases to embeds steel
frame columns grid line 3, wood saddle/knife plate assemblies to W 14x68 steel
beam grid line L, and inspected high strength A325 bolting at the steel beam &
column connections.
The onsite welding & high strength bolting inspected above appeared to be in
substantial conformance with the plans, and the quality requirements of the AWS
D1.1 Structural Welding Code & the AISC/RCSC Specification for high strength
bolting.
Inspector/Technician: Douglas E Young
Douglas E. Young
ICC Certification #5102224
Structural Welding Special Inspector
uctural Ste 1 �& hbltin Special Inspector
p ay-
pplie Firep�r g pecial Inspector
® Douglas E Young
CWI 96070131
QC1 EXP. 7/1/2023