HomeMy WebLinkAboutCorrespondence 2Vandø-Z4r.t¿r¿)brreøyndaz,æ
Colleen W¡rth ELRE-ya zl -b76 ?
From:
Sent:
To:
Subject:
Bruce Baft h < bruce @red hou sea rchitectu re.com >
Monday, February 7,2022 4:44 PM
Colleen Wirth
Re: [External] 138 Kingbird - BLRE-6769
OK thanks Colleen, l'll wait to hear from Sam. The fixed window in the master shower is tempered per the window/door schedule from Architectural Windows
andDoors. Also, lorderedatemperedpiecefortheExerciseRoom,thestaírwasnotintendedtobethatfarnorthintotheroom.
Have a good day, Bruce
From : Col lee n W i rt h <cwi rth @ ga rf ie ld-cou nty.com>
Date: Monday, February 7,2022 at 9:02 AM
To: Bruce Ba rth <bruce @ red housea rchitectu re.com>
Subject: L38 Kingbird - BLRE-6769
Hi Bruce,
ThÍs morning I was able to finish redlining the AMENDED FLOOR PLANS for 138 KINGBIRD. You will receive a call from Sam lrmen, Permit Technician, when the
invoice for the ADDENDUM is made ready. I charged 2 hrs @ $50 extra plan check fee. 5o you are aware the "egress window" at top of stairs serving the
"exercise room" needs to be "tempered" per R308.4 -- due to location adjacent stairs.
After walking the job site during your insulation inspection, I do recommend taking another look at the glazing in the master shower area' 20L5 IRC Section
R308.4 #5 requires safety glazing in wet locations wherever within 60 inches of a standing or walking surface. The fixed exterior window in the shower is
perhaps less than 60 inches above finished floor.... I was able to visually locate the "etching" for LOW E but no expressed reference that states
tempered". Please double check to ensure tempered glazing in required locations.
Colleen Wirth
Plans Examiner
Garfield County Building Division
108 8th Street, Suite 401
Glenwood Springs, CO 81601
cwi rth @ ea rf iel d-co u ntv. com
office (970) 945-L377 ext. L610