HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF P ERMIT
BLRE-0 5-22-7 526
Keila Va lenzuela
New S/F Dwelling with attached garage
(future barns/cabin/ponds N?Tincluded under this permit)
893 CR 102, Carbondale
Sec 20, 1.07 , R.B7 - 239120300277
1) ALL WORK SHALL COMpLy W|TH THE 2015 TNTERNATIONAL RESIDENTIAL CODE (l.R.C.)
AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C'C.)
2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED lN THE
ATTACHED "GARFIELD COU NTY BU I LDING REOUI REM ENTS". NU M BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD.
ELECTRICAL ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL
FIRE DISTRICT.
5) pRE FABRICAIED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR AT TIME OF FRAME
INSPECTION. (Elevation over 7,000 ft, Roof Snow Load 50 PSF TCLL)
ó) opEN HOLE SOILS REPORT tS REOUTRED AT FOOTING INSPECTION AND PRIOR TO ANY
CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE
BUILDING INSPECTOR. 2,OOO PSF
7) ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS)TO BE INSPECTED BY A
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. PROVIDE ENGINEER'S
FINAL REPORT TO GARFIELD COUNTY PUBLIC HEATH PRIOR TO SCHEDULING A FINAL
BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY.
B) SOME FIELD WELDING SHOWN ON STRUCTURAL Sheet 53.1. HIGH STRENGTH BOLTING
AND FIELD WELDING REOUIRES SPECIAL INSPECTOR. PROVIDE APPROVAL REPORT AT
FRAMING INSPECTION.