HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: Lot 13, Rapids on the Colorado, New Castle, CO 81647
Parcel No.: 218104307013
Owner Name: Eddie and Cherri Murray Owner Phone: (970) 948-1429
Designed By: Sopris Engineering, LLC. Designer Phone: (970) 704-0311
Number of Bedrooms _4__Minimum Tank Capacity _1,500-gal__Minimum Absorption_656.25 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7597________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 06/24/2022 Expiration Date 06/24/2023
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by Sopris
Engineering, LLC. dated June 10, 2022. Changes must be approved by Garfield County Public Health
and the designer prior to construction.
The new OWTS will serve a new three-bedroom residence and potential future one-bedroom
addition. The system will consist of a new, two-compartment 1,500-gallon septic tank set level with
access to grade with a high-head pump in the second chamber of the tank. Effluent will be pressure-
dosed to distribute effluent to 656.5 ft2 of STA. The new STA will consist of an unlined sand filter bed
constructed of 2 feet of secondary sand material. The pump and effluent lines will be constructed of
1.5-inch diameter Schedule 40 PVC. The laterals in the bed will be connected with a level manifold,
and the laterals shall have 5/32-inch diameter orifices facing down spaced every 3 feet on-center
(O.C.), installed on GeoMat placed directly on the sand. Inspection ports are to be installed at each
corner of each bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
06/24/2022
Issued By: Garfield County Environmental Health
Department
Date