SOIL AND FOUNDATION INVESTIGATION
F'OR A
PROPOSED RESIDENCE
LOT 1, THE RANCH AT COULTER CREEK PUD
AT CATTLE CREEK RIDGE ROAD
GARFIELD COUNTY, COLORADO
PROJECT NO. 19.3377
NOVEMBER 9,2019
.r*4S.,î&+¿-,
,'Sþ:o*''" ":.ri:."ffi"t',
: -.fi:.::
: .** * "/\,L*'JJ{ tffi;W*'ii;,*ïï,",1,:,Y"'
PREPARED FOR:
ROBERT LEVIN
LEVINIUS LLC
218 E. VALLEY ROAD, STE 104 PMB 375
CARBONDALE, CO 81623
P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 rvww.LKPEnqineering.com
TABLE OF CONTENTS
EXECUTIVE SUMMARY ............
SCOPE OF STUDY
SITE DESCRIPTION..
PROPOSED CONSTRUCTION......
FIELD INVESTIGATION
SUBSURFACE SOIL AND GROUNDWATER CONDITION ...
F OLIND ATION RE C O MMENDATION S
SLAB CONSTRUCTION....
RETAINING WALLS
UNDERDRAIN SYSTEM
SITE GRADING AND DRAINAGE.......
LAWN IRRIGATION ...............
LIMITATION
FIGURES
LOCATION SKETCH
SUBSURFACE EXPLORATION LOGS.
SWELL-CONSOLIDATION
PERIMETER DRAIN DETAIL.
2
2
2
J
J
J
4
5
6
6
7
7
8
.DRAWING NO. 1
.FIGURE NO's 1-2
. FIGURE NO's 3-4
.FIGURE NO. 5
LKP Engineering,Inc.
EXECUTIVE SUMMARY
The proposed residence should be supported with
conventional type spread footings, designed for an allowable soil
bearing pressure of 1000 psf. They should construct the footings
on the undisturbed calcareous, gypsiferous, silty clay with some
gravel. See Foundation Recommendations.
SCOPE OF STUDY
This report presents the results of a subsurface Soil and Foundation Investigation for a
proposed residence to be constructed on Lot 11, The Ranch at Coulter Creek PUD, at Cattle
Creek Ridge Road (address number not assigned yet), Garfield County, Carbondale, Colorado.
The purpose of the subsurface soil and foundation investigation was to determine the
engineering characteristics of the foundation soil and to provide recommendations for the
foundation design, grading, and drainage. Geologic hazard studies are outside of our scope of
services.
SITE DESCRIPTION
Lot 11, The Ranch at Coulter Creek PUD is 9.637 acres (according to the survey by
SGM, Inc, Robert Brandeberry, PLS, emailed by Whit and the Garfreld County GIS) and it is
located at the southeast from the intersection of Cattle Creek Ridge Road and Meadow Circle,
and south from 1003 Cattle Creek Ridge Road, Garfield County, Colorado. Vegetation within
the proposed building site consisted of tall grass. The topography within the selected building
LKP Engineering,Inc
J
area (where the two test pits had been dug) was flat to moderate with average slopes from about
5 percent. Drainage is to the south and southeast. Cattle Creek Ridge Road runs along the west
side, southwest and south side of the property. To the north there is an existing residence and to
the east is the Ranch at Coulter Creek PUD Private Open Space. Lot I was vacant.
PROPOSED CONSTRUCTION
We have assumed that the proposed residence will be two story, wood frame construction
without a basement, on a concrete foundation, with an attached garage. We anticipate loads to be
light, typical of residential construction.
If the finalized plans differ significantly from the above understanding, they should
notiÛr us to reevaluate the recommendations of this report.
FIELD INVESTIGATION
The field investigation, conducted on November 5, 2019, consisted of logging and
sampling two test pits. The test pits were dug by your excavator, Ryan Ivy. Approximate
locations of the test pits (as marked by you) are shown on Drawing No. 1. We show the soil
profile of the test pits on the Subsurface Exploration Logs, Figure No's 1 and2. Soil samples for
laboratory soil analysis and observation were taken at selected intervals.
SUBSURFACE SOIL AND GROUNDWATBR CONDITION
The soil profiles encountered in the two test pits were fairly uniform. Test Pit No. I had
about 3 feet of topsoil and blocky clay over light brown, calcareous, gypsiferous, silty clay with
basalt gravel to cobble size rocks and pockets of sandy gravel, to the maximum depth explored
of about 7.3 feet. Test Pit No. 2 had about 2.5 feet of topsoil and blocky clay over light brown to
LKP Engineering,Inc.
4
reddish, calcareous, gypsiferous, silty, sandy clay with gravel size volcanic rocks to the
maximum depth explored of 7 feet. Ground water or bedrock were not encountered in the test
pits. We sampled the soil in the test pits at random intervals. The samples were tested for natural
moisture content, swell-consolidation potential, and natural dry density. The test results are
shown on Figure numbers 3 and 4. The clay soil samples had high moisture content of 14.7 and
19.5 percent. The high moisture content might mask possible swelling potential of the clay soils.
Swelling soils were encountered on the surrounding lots.
FOUNDATION RECOMMENDATIONS
The proposed residence should be supported with conventional type spread footings,
designed for an allowable soil bearing pressure of 1000 psf. They should construct the footings
on the undisturbed calcareous, gypsiferous, clay with some gravel, below the topsoil and blocky
clay. If the entire foundation is supported on the clay soil encountered at the bottorn of the test
pits at depth of 7 feet, they can use a maximum allowable soil bearing pressure of 2000 psf.
The clay soil samples had high moisture content of 14.7 and 19.5 percent. The high
moisture content might mask possible swelling potential of the clay soils. Swelling soils were
encountered on the surrounding lots. The completedfoundation excavation must be observed and
tested by the undersigned engineer to verify that the soil conditions encountered during
construction are as anticipated in this report. If swelling soils are encountered during the open
hole observation, the foundation vvill have to be redesigned to account þr the soil conditions
prevailing in the foundation excavation.
We recommend a minimum width of 16 inches for the continuous footings and 2 feet for
the isolated footing pads. Continuous foundation walls should be reinforced top and bottom to
span an unsupported length ofat least 10 feet.
The proposed foundation should be set at a minimum depth of four feet below the
finished grade or at the rninimum depth required by the local building code. The foundation
LKP Engineering, Inc.
5
excavation should be free from excavation spoils, frost, organics and standing water. We
recommend proof-rolling of the foundation excavation. Soft spots detected during the proof-
rolling, should be removed by overexcavation. Any overexcavation within the proposed
foundation should be backfilled, in 8 inches loose level lifts and compacted to l00o/o of the
maximum dry density and within 2 percent of the optimum moisture content as determined in a
laboratory from a Standard Proctor test (ASTM D-698). A structural fill, placed under footings
should be tested by a qualified professional.
SLAB CONSTRUCTION
The natural on-site soils, exclusive of topsoil and organics, are suitable to support lightly
loaded slab-on-grade construction. The subgrade for the slab-on-grade construction should be
proof compacted to detect and remove soft spots. They should backfill overexcavated soft spots
and other underslab fill with the on-site soil, free from topsoil and organics, or other suitable
material, compacted to a minimum of 95 percent of the maximum standard Proctor density
(ASTM D-698). Suitable material should be free from topsoil, organics and rock fragments
greater than 3 inches.
The concrete slab should be constructed over a 4-inch layer of clean gravel consisting of
-314 inch gravel with at least 50% retained on the No. 4 sieve and less than 3 percent passing the
No. 200 sieve.
They should reinforce the concrete slab-on-grade and score controljoints according to
the American Concrete Institute requirements and per the recommendations of the designer to
reduce damage due to shrinkage. The concrete slab should be separated from the foundation
walls and columns with expansion joints to allow for independent movement without causing
damage.
LKP Engineering,Inc.
6
RETAINING WALLS
Foundation walls retaining earth and retaining structures that are laterally supported
should be designed to resist an equivalent fluid density of 60 pcf for an "at-rest" condition.
Laterally unrestrained structures, retaining the on-site earth, should be designed to resist an
equivalent fluid density of 40 pcf for the "active" case.
The above design recommendations assume drained backfill conditions and a horizontal
backfill surface. Surcharge loading due to adjacent structures, weight of temporary stored
construction materials and equipment, inclined backfill and hydrostatic pressure due to
undrained backfill should be incorporated in the design. They should try to prevent the buildup
of hydrostatic pressure behind the retaining wall.
Passive earth pressure of 360 psf can be used for the lateral pressure against the sides of
the footings. Resistance to sliding at the bottom of the footings can be calculated based on a
coefficient of friction of 0.5. Undisturbed soil or a structural fill compacted to 100 percent of the
maximum dry density and within 2percent of the optimum moisture content will be used to
resist lateral loads at the sides of the footings.
UNDERDRAIN SYSTEM
To reduce the risk of surface water infiltrating the foundation subsoil, we recommend
installation of a foundation perimeter drain (see Figure No. 5). The foundation perimeter drain
should consist of a 4-inch diameter, perforated pipe, sloped to a suitable gravity outlet, at a 114
inch per foot for flexible or at a 1/8 of an inch for rigid pipe. The bottom of the trench adjacent
to the footing should be lined with a polyethylene moisture barrier glued to the foundation wall.
The drain pipe should be covered with a minimum of 6 inches of -3/4-inch free-draining
granular material. Geotextile (Mirafi l40N or equivalent) should be used to cover the free-
draining gravel to prevent siltation and clogging of the drain. The backfill above the drain should
LKP Engineering, Inc.
7
be granular material to within 2 feet of the ground surface to prevent a buildup of hydrostatic
pressure.
SITE GRADING AND DRAINAGE
The following recommendations are general. Exterior backfill should be compacted at or
near the optimum moisture content to at least 95o/o of the maximum standard Proctor density
under pavement, sidewalk and patio areas and to at least 90% of the maximum standard Proctor
density under landscaped areas. They should use mechanical methods of compaction. Do not
puddle the foundation excavation.
The site surrounding the building structure should slope away from the building in all
directions. A minimum of 12 inches in the first l0 feet is recommended in unpaved areas, and
three inches in the first 10 feet in paved areas. The top of the granular foundation backfill should
be covered with a minimum of 1 foot of relatively impervious fill to reduce the potential of
surface water infilhating the foundation subsoils.
Surface water naturally draining toward the proposed building site should be diverted
around and away from it by means of drainage swales or other approved methods. The roof
drains and downspouts should extend and discharge beyond the limits of the backfill.
LAWN IRRIGATION
It is not recommended to introduce excess water to the foundation soils by installing
sprinkler systems next to the building. The installation of the sprinkler heads should insure that
the spray from the heads will not fall within 10 feet of foundation walls, porches or patio slabs.
Lawn irrigation must be controlled.
LKP Engineering, Inc
8
LIMITATION
This report has been prepared according to locally accepted Professional Geotechnical
Engineering standards for similar methods of testing and soil conditions at this time. The type of
soil testing was selected by the owner and general contractor as the preferred method for the soil
and foundation investigation over a soil and foundation investigation with a drill rig. There is no
other wawanty either expressed or implied.
The findings and recommendations of this report are based on field exploration,
laboratory testing of samples obtained at the specific locations shown on the Location Sketch,
Drawing No.l and on assumptions stated in the report. Soil conditions at other locations ma)¡
varv. which may not become evident until the foundation excavation is completed. If soil or
water conditions seem different from those described in this report we should be contacted
immediately to reevaluate the recommendations of this report. We are not responsible for
technical interpretation by others of the data presented in this report.
This report has been prepared for the exclusive use of Robert Levin, for the specific
application to the proposed residence on Lot 11, The Ranch at Coulter Creek PUD, at Cattle
Creek Ridge Road, Carbondale, Garfield County, Colorado.
Sincerely,
LKP ENGINEERING,INC.
\¿
¿f-'-;ffiãr*t**Z.ë.?
Luiza Petrovska, PE
J:\ WP X4-LKP\ 2019\19-3377 CLAY-BASALT-PITS.DOCX
LKP Engineering, Inc
rTt,3ãô*.....-iiI,ñ.i9ffi4å>zTOT+¡mo".x==*lrñ8->-+6óZZOolÌ@i>TØmE+umñø>1>le42Øm3Fot!i¡trôz!ÞFf¡tû\oo\ùèI9_@!-9pu9@o@tôox9r:x=-{9{u_x-uÔrof@o='IolÞ'rñFoRllo?C^Hìatrt-o-tô>c)-¡>-J'ï-lIñlm5i"{8fiı=xË-ì4cioHoPfíF9ðdooooÅm^!aomoIz9(o(,(,!--,tØoITIII--¡oIn€zoz9
DATE OBSERVED: NOVEMBER 5, 2019
ELEVATION:
Test Pit f I
DEPTH
FEET
5
Y
M
B
o
L
s
A
M
P
L
E
DESCRPNON OF MA\ERIAL
AND SAMPLE LOCANON
LABORATORY
TEST RESULTS
REMARKS
5
_10
-15
_20
/
Topsoil, sÍlty wìth fìne roots over
blocky clay
r-l
Lìght brown to reddish, colcoreous,
g¡psiferous, silty cloy with volconic rocks
ond pockets of sondy grovel
DD: 98.4 pcf
MC: 14.7 %
Bottom of Test Pìt @ 7.J feet No Ground \Uater
Encountered
I,EGEND:
trI
DD
MC
- 2-ínch 0.Ð. Colifornio Liner Somple
- Bulk Somple
- Naturol Dry Density (pcf)
- Natural Moisture Content (%)
- Percent Passing No. 2O0 Sieve
- LìquÍd LimÌt
- PlosticÍty lndex
- Ground water
200
LL
PI
GW
IJ(P ENGINEERING, INC.SUBSURFACE EXPTORATION tOG
ffiøECf NO.:l9-JJ77
nq)RE NO.:I
DATE OBSERVED: NOVEMBER 5, 2019
ELEVATION:
Test Pit f 2
DEPfH
FEET
5
Y
M
B
o
L
5
A
M
P
L
E
DESCRIPTION OF MATERIAL
AND SAMPLE LOCANON
LABORATORY
TEST RESULTS
REMARKS
5
_10
-15
_20
/
Topsoì|, sìlty with fine roots over
blocky cloy
tr
r-l
Líght brown to reddish, colcoreous,
g¡psiferous, sílty cloy with grovel síze
volcanic rocks
DD= 99.1 pcf
MC: 10.9 %
DD= 95.9 pcf
MC= 19.5 %
Bottom of Test Pìt @ 7 feet No Ground Woter
Encountered
LEGEND:
tl - 2-inch O,D. Colifornìa Liner Somple¡ - Bulk SompleDD - Notural Dry Density (pcf)
MC - Naturol Moìsture Content (7)
-200 - Percent Passìng No. 2OO SieveLL - Liquîd LimitPl - Plostìcity lndexGW - Ground woter
tKP ENGINEERING, INC.SUBSURFACE Ð(PTORATION tOG
PROIECT NO.:'t9-3377
ndtRE No.:2
0
c.9
(r)
eo
,ìo
bR
co'E -4(¡)
a-
Eoo-5
_z
-l
-2
-6
-1
-2
2
-4
-5
0
c.e
(¡t
fo
a-
'ı
N
co
(D
fn
Pa-
Eoo
-6
LKP Engineering, lnc.Swell - Consolidation Test Results
PRO,ECT NO.:t9-3J77
NAURE NO,:J
tttttttttt
.COMPRESSION WHEN WETTED UNDER
CONSTANT PRESSURE OF IOOO PSFlltttttttt
o.t 1.0 10 't00
APPLIED PRESSURE - ksf
Somple of: Light brown, colcareous, g¡¡psiferous, silty cloy
Noturol Dry Unít Weight 98.4 pcf
Noturol Moisture Content : 14.7 percent
From: Test Pit I ot 7.3'
t t tt|| t t
4OMPRESSION WHEN WETTED UNDER
CONSTANT PRESSURE OF |OOO PSFtltttttttr
\
\
o.t 1.0 'to 100
APPLIED PRESSURE - ksf
Somple of: Light brown, sondy, calcareous cloy
Noturol Dry Unit WeÍght : 99.1 pcf
Naturol Moìsture Content : 10.9 percent
From: Test Pit 2 of 3.5 feet
I
0
c.e(t,cù
,ìo
N
to'B -4
Pa-
Foo-s
-3
-l
-2
-6
t tl||t t t
/COMPRESSION WHEN WETTED UNDER
CONSTANT PRESSURE OF 'IOOO PSF
0.1 1.0 10 't00
APPLIED PRESSURE - ksf
Sample of:Light brown, clocoreous Cloy
Naturol Dry Unit Weight 95.9
Notural Moisture Content : 19.5
From: Test PÍt No. 2 of 7 feet
pcf
percent
LKP Englnccrlng, lnc.Swell ConsolÌdation Test Results t9-JJ77
4
AWAY FROM BUILDING
BACKFILL WITH A MINIMUM
OF ONE FOOT OF RELATIVELY
IMPERVIOUS SOIL
FABRTC (MrRAFr
l40N oR EOUTVALENT)
3/4-INCH DIAMETER, COARSE,
CLEAN CRUSH ROCK
30 MIL MINIMUM THICKNESS,NCH DIAMETER PERFORATED PIPE SLOPED TOPLASTIC LINER, GLUED TO A DAYLIGHT LOCATION AWAY FROM THE
FOUNDATION AT 1/4-INCH PER FOOT FOR
FLEXIBLE AND 1/B-INCH MINIMUM FOR RIGID PIPE
FOUNDATION WALL
CML/GEOTECHNICÂL
Engineering, fnc.
P.O. Box 724, Eoqle, C0 81631
Tel (970) 390-0J07 www.LKPEngineering.com
LKP
PERIMETER DRAIN
LOT 1, THE RANCH AT COULTER CREEK
CATTLE CREEK RIDGE ROAD
GARFIELD COUNTY, COLORADO
19-3377
scALE: N.T.s.