HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 1002 Skipper Lane, Carbondale, CO 81623
Parcel No.: 239130405001
Owner Name: Kevin L. Patrick and Andrea M. Wendell Owner Phone: (970) 379‐5458
Designed By: LKP Engineering Designer Phone: (970) 390‐0307
Number of Bedrooms _3__Minimum Tank Capacity _1,000‐gal__Minimum Absorption_693 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐7664________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 07/26/2022 Expiration Date 07/26/2023
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by LKP
Engineering, Inc. dated January 6, 2022. Changes must be approved by Garfield County Public Health
and the designer prior to construction.
The new OWTS will serve a new three‐bedroom residence. The system will consist of a new, three‐
compartment 1,000‐gallon septic tank set level with access to grade with an effluent filter in the
outlet tee of the second chamber of the tank and a high‐head pump in the third chamber of the
tank. Effluent will be pressure‐dosed to a level manifold to distribute effluent to 720 ft2 of STA. The
new STA will consist of an unlined sand filter bed constructed of 3 feet of secondary sand material
with four laterals. The pump and effluent lines will be constructed of 1.5‐inch diameter Schedule 40
PVC. The laterals in the bed shall have 1/8‐inch diameter orifices facing up spaced every 4 feet on‐
center (O.C.) except for the last orifices which will face down, installed in Infiltrator Quick4 chambers
placed directly on the sand. The chambers shall be configured in a four‐row bed layout, with 15
chambers per row (60 chambers total). Inspection ports are to be installed at each corner of each
bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
07/27/2022
Issued By: Garfield County Environmental Health
Department
Date