brad jordan < bradjord ana rchitect@ g mal l.com >
Wednesday, August 10,2A22 9:45 AM
Colleen Wiñh
Re: [External] requested information - Clausen Basement ADU conversion project
tbtb F,re €epnþøt
LET ME KNOW IF THE REVISED PLAN IS CORRECT FOR YOUR REVIEW AND APPROVAL. I WILL GLADLY GET TWO COPIES
PRINTED OFF AND IN YOUR HANDSTODAY.
BRAD
On Wed, Aug 10, 2022 at9:43 AM Colleen Wirth <cwirth@garf¡eld-countv.com> wrote
Cool. That's awesome
Colleen Wirth
Plans Examiner
Garfield County Building Division
108 8th Street, Suite 401
Glenwood Springs, CO 8l-601
cwi rth @ garfield-cou ntv. com
office (970) 945-1377 ext. l-6L0
From: brad jordan <bradiordanarchitect@gmaíl.com>
Sent: Wednesday, August 1.A,2022 8:56 AM
To: Col leen Wirth <cwi rth @garfiel d-cou ntv.com >
Subject: Re: [External] requested information - Clausen Basement ADU conversion project
I REVISED THE PLAN AND PROVIDED THE FIRE RESISTANCE DETAIL. YOU ARE CORRECTTHAT WE ONLY HAD 1 LAYER,
WHICH HAS BEEN CHANGED ON THE DRAWING I REVISED AND SENT OVER. I CHANGED THE NOTE TO 2 LAYERS AND
ADDED THE DETAIL.
BRAD
On Wed, Aug 1"0, 2A22 at 8:51 4M Colleen Wirth <cwirth@sarfield-countv.com> wrote
Oh sorry, l'll check again. I was seeíng a notation on the floor plan that stated L layer of 5/8 type x in the ceiling
l¡d. l'll circle back to the plans once l'm finished with the review l'm currently working on!
Colleen Wirth
Plans Examiner
Garfield County Building Division
108 8th Street, Suite 401
Glenwood Springs, CO 81"601
cwirth @ ga rfield-cou ntv.com
office (970) 945-1377 ext. 161-0
From : brad jordan <brad iordanarchitect@sma ¡ l.com>
Sent: Wednesday, August 10,2022 8:27 AM
To : Col leen Wirth <cwirth @earfíeld-cou ntv.com>
Subject: Re: IExternal] requested information - Clausen Basement ADU conversion project
Colleen,
The basement currently exists as an open area with exteríor access and windows on one side {walk out). The floor
framing system above is currently exposed. The main residence 'stacks' above a crawl space and the unfinished
basement/proposecì ADij. So, yes, we have a verticai separation wiih 2 iayers of 5/8" type X sheetrock ihroughout on
the ADU ceilíng. The only horizontal separatÍon would be between the ADU and mechanical room area. There is a
door that will be a 'locl< off' situation ancl I assume this would have to be a rated door, similar to a garage separation,
along with 5f8" type X sheetrock on each side of this wall. Mr. Clausen's son, daughter-ín-law and child will be livíng
in the basement/ADU.
Brad
On Wed, Aug 10, 2A22 at 8:18 AM Colleen Wirth <cwirth@sarfield-countv.com> wrote:
2
Hello Brad,
l'm struggling to understand the adjoining portions of the exísting building'.
Are you províding a vertical fire separation only?
Or and vertical and horizontal fire separations separating the ADU ín the converted basement from the existing living
space above it?
l'm only seeing the lower level and cannot see the existing dwelling assembly and floor plan layout ín story over the
ADU.
Colleen Wirth
Plans Examiner
Garfield County Building Division
L08 8th Street, Suite 401
Glenwood Springs, CO 81601
cwi rth @ ga rf ield-cou ntv.com
office {970) 945-L377 ext. 1610
From: brad jordan <bradiordanarchitect@qmail.com>
Sent: Wednesday, August LO,2A22 8:L3 AM
To: Col leen Wi rth <cwirth @garf ¡eld-cou ntv.com>
Subject: Re: IExternal] requested information - Clausen Basement ADU conversíon project
Upon review of this document, my provided detail addresses the horizontal separation between the ADU and single
family resídence above. There are no penetrations in the floor system wíth mechanical (heating), as the area is
heated with radiant heat that already exísts. The lighting at the ceilingfloor above would comply with the detaíl
indícated Ín your pdf, as there are not any floor outlets/electrical penetrations in the floor above. There isn't an attic
space to consider, as the ADU is completely under a portion of the existing residence.
J
My detail also indicates a layer of 5/8" type X sheetrock on each side of the common wall between the ADU and the
mechanical room. lf we need to provide 2 layers of this sheetrock on the interior side of the ADU, I can modify the
detail accordingly.
Brad
On Wed, Aug L0, 2022at 8:00 AM Colleen Wirth <cwirth@earf¡eld-counÛ.cam> wrote
See attached PDF
# 3 retrofit/ remodel may apply
Consider MEP details carefully when planning the Separatíon
Colleen Wirth
Plans Examiner
Garfield County Buíldíng Dívision
108 8th Street, Suite 40L
Glenwoocl Spríngs, CO 8L601
cwi rth @sa rfiel d-cou nW. com
office {970) 945-t377 ext. 1610